1. Ifihan
The xTool SafetyPro AP2 is an advanced smoke purifier designed to enhance the safety and cleanliness of your laser engraving and cutting environment. It features a multi-stage filtration system, including a revolutionary SuperCyclone technology, to effectively remove dust, harmful chemicals, and odors generated during laser processing. This manual provides essential information for setting up, operating, maintaining, and troubleshooting your SafetyPro AP2 to ensure optimal performance and a healthier workspace.

Figure 1: xTool SafetyPro AP2 Smoke Purifier
2. Alaye Aabo
Always prioritize safety when operating laser equipment and accessories. The xTool SafetyPro AP2 is designed to mitigate risks associated with airborne particles and fumes, but proper usage is crucial.
- Afẹfẹ: While the AP2 significantly reduces airborne contaminants, ensure adequate room ventilation, especially when processing materials that produce strong fumes.
- Itọju Ajọ: Regularly check and replace filters as indicated by the device or software to maintain optimal purification performance. Clogged filters can reduce efficiency and potentially lead to hazardous air quality.
- Aabo Itanna: Connect the purifier to a grounded power outlet. Do not operate with damaged power cords or plugs.
- Ibi: Place the purifier on a stable, level surface, away from heat sources or flammable materials. Ensure proper airflow around the unit.
- Ibamu Ohun elo: The AP2 is designed for typical laser engraving and cutting materials. Consult xTool support for specific concerns regarding unusual materials.
3. Awọn ẹya Ọja
3.1. Ètò Ìṣàlẹ̀ Àwọn Fẹ́ẹ́rẹ́ Mẹ́ta
The SafetyPro AP2 employs a comprehensive 6-layer filtration system to capture 99.99% of dust and odors, ensuring a clean and safe breathing environment during laser processing. This robust system is designed for maximum purification efficiency.

olusin 2: exploded view of the 6-layer filtration system.
3.2. SuperCyclone Technology
The first laser purifier with SuperCyclone Technology, featuring 36 cyclones that capture 99% of large particles before they reach the main filters. This significantly extends the lifespan of subsequent filters by preventing premature clogging, offering up to 10 times longer filter life compared to traditional systems.

Figure 3: SuperCyclone Technology in action.
3.3. Ultra-Dense Carbon Mesh Filter
Effectively absorbs odors and harmful chemicals with an advanced Ultra-Dense Carbon Mesh filter. This exclusive xTool technology expands the carbon surface area for thorough odor adsorption, ensuring stronger filtration and a cleaner, safer workspace. It is particularly effective against VOCs and other strong smells from materials like acrylic and leather.

Figure 4: VOC levels with and without Carbon Mesh filtration.
3.4. Intelligent Control & Quiet Operation
The AP2 offers smart features including auto-sync with xTool lasers, tailored settings for every material, and real-time filter monitoring. Its low-dB operation ensures a quiet working environment, enhancing the efficiency of your laser processing without disruptive noise.

Figure 5: Intelligent control via xTool software.
4. Eto Itọsọna
Follow these steps to set up your xTool SafetyPro AP2 for the first time.
- Unboxing: Carefully remove the purifier and all accessories from the packaging.
- Yọ Awọn fiimu Aabo: Peel off any protective films from the purifier's surfaces, especially the front panel.
- Mura awọn Ajọ: The filters come pre-installed but are individually wrapped. Open the purifier door by pulling the handle. Take out all filters one by one (do not remove the cyclone filter). Remove their respective protective bags.
- Tun awọn Ajọ sori ẹrọ: Install the filters and cyclone back into the purifier. Ensure each filter is pushed all the way in and aligned correctly. Close the door securely.
- Connect Exhaust Pipe: Stretch the smoke exhaust pipe and connect one end to the appropriate pipe connector (Pipe connector 1 for xTool S1 and F1 Ultra, Pipe connector 2 for xTool M1 Ultra and F1). Connect the other end of the pipe to the airflow inlet on the back of the AP2.
- Asopọ agbara: Connect the power cable to the power port on the back of the AP2 and then to a grounded electrical outlet. Switch on the power using the red switch.
- Bluetooth Dongle (Optional): For intelligent control and monitoring, connect the Bluetooth dongle to your xTool laser machine.
Video 1: xTool SafetyPro AP2 Smoke Purifier Unboxing & Setup Guide.
5. Awọn ilana Iṣiṣẹ
The SafetyPro AP2 offers both manual and automatic operation modes.
5.1. Auto Mode (Recommended)
When connected to a compatible xTool laser machine via Bluetooth, the AP2 can automatically adjust its airflow based on the material being processed. This ensures optimal purification for different materials without manual intervention.
- Muu ṣiṣẹ: Press the 'Auto' mode button on the purifier's control panel or select 'Auto' in the xTool Creative Space software.
- Amuṣiṣẹpọ: The purifier will automatically start and shut down with your xTool laser, and you can customize the shutdown time to ensure all fumes are expelled.
- Tailored Settings: The software automatically matches the optimal filtration mode based on the material selected by the user.
5.2. Ipo Afowoyi
You can manually control the airflow level directly from the purifier's control panel.
- Atunse ṣiṣan afẹfẹ: Use the airflow switch button to cycle through different airflow levels (indicated by LEDs).
Video 2: xTool SafetyPro AP2 Smoke Purifier with SuperCyclone System - Features and Operation.
6. Itọju
Regular maintenance ensures the longevity and efficiency of your SafetyPro AP2.
6.1. Cleaning the SuperCyclone Filter
The SuperCyclone filter is washable and reusable, significantly reducing replacement costs.
- Remove Cyclone: Pull out the cyclone filter unit from the purifier.
- Tutu: Remove the six screws holding the cyclone unit together and carefully disassemble it.
- Mọ: Spray a mild cleaner on the dirty parts of the cyclone. Soak the cyclone parts in water for 10 minutes. Wash all cyclone parts thoroughly with running water.
- Dry & Reassemble: Wait for the cyclone parts to dry completely before reassembling and installing them back into the purifier.
6.2. Filter Rirọpo
The xTool Creative Space software provides real-time filter lifetime monitoring, indicating when other filters need replacement.
- Abojuto: Check the filter lifetime indicators in the xTool Creative Space software.
- Rọpo: When a filter reaches its end of life, open the purifier door, remove the old filter, and insert a new one. Ensure it is correctly aligned.

Olusin 6: Pariview of maintenance features.
7. Laasigbotitusita
If you encounter issues with your xTool SafetyPro AP2, consider the following common solutions:
- Ko si Agbara: Ensure the power cable is securely connected to both the purifier and the wall outlet. Check the power switch on the back of the unit.
- Poor Purification: Verify that all filters are correctly installed and not clogged. Clean the SuperCyclone filter if it's dirty. Check the filter lifetime in the software and replace any expired filters.
- Ariwo Dani: Ensure the purifier is on a stable surface. Check for any obstructions in the airflow path or fan.
- Awọn oran Asopọmọra: Ensure the Bluetooth dongle is properly inserted into your xTool laser machine. Restart both the purifier and the laser machine.
- Software Not Recognizing Purifier: Update your xTool Creative Space software to the latest version.
For persistent issues, please contact xTool customer support.
8. Imọ ni pato
| Ẹya ara ẹrọ | Sipesifikesonu |
|---|---|
| Nọmba awoṣe | MAX-S300-P01 |
| Iwọn Nkan | 46 iwon (20.9 kilo) |
| Ọja Mefa | 25.59 x 16.14 x 26.38 inches |
| Sisẹ System | 6-Layer (SuperCyclone, Pre-Filter, Medium Efficiency, Activated Carbon, Ultra-Dense Carbon Mesh, HEPA) |
| Dust Removal Efficiency | 99.99% (PM2.5, 0.3µm Dust, Allergens) |
| Odor Yiyọ ṣiṣe | 97.97% (Odors), 98% (VOCs), 100% (Toluene) |
| Àwọ̀ | Funfun + Dudu |
| Ilu isenbale | China |
9. Atilẹyin ọja ati Support
The xTool SafetyPro AP2 comes with a 1-year warranty from the date of purchase.
For technical assistance, warranty claims, or general inquiries, please utilize the following xTool support channels:
- Imeeli Atilẹyin: Contact xTool directly via email for detailed inquiries.
- Iwiregbe Live: Ṣabẹwo si xTool osise naa website for live chat support during business hours.
- Atilẹyin foonu: Call the dedicated customer service line for immediate assistance.
- Ẹgbẹ Facebook: Join the official xTool Facebook community for peer support and updates.
Please have your product model number (MAX-S300-P01) and purchase information ready when contacting support.





