ACiQ B0DHFF2DKL

AciQ 2.5 Ton 17 SEER2 Atọka Afọwọṣe Eto Olumulo Gbona Gbona Inverter Central

Model: B0DHFF2DKL

1. Ifihan

This manual provides essential information for the installation, operation, and maintenance of your ACiQ 2.5 Ton 17 SEER2 Central Inverter Heat Pump System. This system is designed to provide efficient heating and cooling for residential and light commercial applications. Please read this manual thoroughly before attempting any installation or operation to ensure proper function and safety.

2. Alaye Aabo

Always prioritize safety. Improper installation, adjustment, alteration, service, or maintenance can cause property damage, injury, or death. Consult a qualified installer, service agency, or the gas supplier for information or assistance. The information contained in this manual is intended for use by qualified service personnel only.

  • Aabo Itanna: Ensure the power supply is disconnected before performing any service or maintenance. All electrical wiring must comply with local and national electrical codes.
  • Imudani firiji: This system uses R-454B refrigerant. Only certified technicians should handle refrigerants.
  • Fifi sori: Installation must be performed by a licensed HVAC professional.
  • Ohun elo Idaabobo Ti ara ẹni: Always wear appropriate personal protective equipment (PPE) such as gloves and safety glasses during installation and maintenance.

3. Key Awọn ẹya ara ẹrọ

  • Imọ ọna ẹrọ oluyipada: Provides precise temperature control, reduced energy consumption, and quieter operation.
  • Iṣiṣẹ to gaju: 18.8 SEER2 and 9.7 HSPF2 ratings for energy savings.
  • Ibi-iṣiṣẹ ti o gbooro: Reliable performance from -13°F to 122°F.
  • Isẹ idakẹjẹ: Indoor noise levels as low as 44 dBA, outdoor unit at 60 dBA.
  • Awọn ohun elo ti o tọ: Rotary compressor, aluminum coil, and fiberglass-free insulation.
  • Firiji Ore Eko: Utilizes R-454B refrigerant.
  • Fifi sori ẹrọ Rọ: Supports horizontal and vertical air handler installation.
  • Awọn iṣakoso Smart: Compatible with wired controllers, WiFi, and third-party thermostats.
  • Integrated Back-up Heat: Includes a 10kW back-up heat kit for supplemental heating.

4. irinše Loriview

The ACiQ 2.5 Ton 17 SEER2 Central Inverter Heat Pump System includes the following main components:

  • Outdoor Condensing Unit (Heat Pump)
  • Indoor Air Handler Unit
  • 10kW Back-up Heat Kit
  • 30' Line Set
  • Gauge Electrical Whip
  • 60A Non-Fused Disconnect Switch
  • WiFi Itaniji
  • Olugbeja gbaradi
  • CPS Charging Adapter
  • Odi Sleeve
ACiQ 2.5 Ton 17 SEER2 Central Inverter Heat Pump System components

Nọmba 1: Pariview of the ACiQ 2.5 Ton 17 SEER2 Central Inverter Heat Pump System, showing the outdoor unit, indoor air handler, 10kW back-up heat kit, thermostat, line set, and various installation accessories.

5. Eto ati fifi sori

Installation of this ACiQ heat pump system requires specialized knowledge and tools. It must be performed by a qualified and licensed HVAC technician to ensure safety, compliance with local codes, and optimal performance. Refer to the detailed installation manual provided with the product for specific instructions.

5.1 Pre-Fifi sọwedowo

  • Verify that the electrical supply matches the unit's requirements (Indoor: 115/208/230V, 60Hz, 1Ph; Outdoor: 208/230V, 60Hz, 1Ph).
  • Rii daju aaye ti o peye fun awọn ẹya inu ati ita gbangba, gbigba fun ṣiṣan afẹfẹ to dara ati iraye si itọju.
  • Confirm that the maximum piping length (164 ft / 50m) and height difference (82 ft / 25m) are not exceeded.

5.2 Air Handler Installation

The indoor air handler unit is designed for flexible installation, supporting upflow, downflow, and horizontal configurations to suit various space requirements.

Multi-Positional Air Handler Unit installation options

Nọmba 2: Diagram illustrating the multi-positional capabilities of the indoor air handler unit, showing options for upflow, downflow, and horizontal installation.

5.3 Ita gbangba Unit Placement

Consider the outdoor unit's dimensions and required clearances for optimal performance and maintenance. The unit features a compact design compared to traditional systems.

Outdoor unit size comparison with traditional units

Nọmba 3: Graphic comparing the smaller footprint of the ACiQ outdoor unit (20 inches clearance) versus a traditional unit (36 inches clearance), highlighting its high efficiency and self-cleaning features.

6. Awọn ilana Iṣiṣẹ

Your ACiQ heat pump system offers advanced control options for comfortable and efficient operation.

6.1 Ipilẹ Awọn ọna Isẹ

  • Ipo itutu: Provides cooling with a capacity of 31,000 BTU/hr. Operates efficiently from -13°F to 122°F ambient temperatures.
  • Ipo alapapo: Provides heating with a capacity of 30,000 BTU/hr at 47°F. Reliable warmth down to -13°F. The 10kW back-up heat kit provides supplemental heat when needed.
  • Ipo Ipele: Circulates air lai alapapo tabi itutu.
  • Ipo Aifọwọyi: A maa n yipada laarin igbona ati itutu lati ṣetọju iwọn otutu ti a ṣeto.
ACiQ outdoor unit operating in extreme heat

Nọmba 4: The ACiQ outdoor unit installed on a patio, demonstrating its ability to operate effectively in extreme heat conditions, up to 122°F.

ACiQ outdoor unit operating in extreme cold

Nọmba 5: The ACiQ outdoor unit partially covered in snow, illustrating its capability to operate in extreme cold temperatures, down to -13°F.

6.2 Smart Controls

The system can be controlled via the included wired thermostat, WiFi-enabled app, or compatible third-party thermostats. The WiFi app allows for remote control and monitoring of your system.

ACiQ Smart Home app and wired thermostat

Nọmba 6: Image showing the ACiQ Smart Home mobile application interface on a smartphone alongside a wired thermostat, demonstrating the system's smart control capabilities for climate management.

7. Itọju

Regular maintenance ensures the longevity and efficiency of your ACiQ heat pump system. Always disconnect power before performing any maintenance.

  • Rirọpo Asẹ Afẹfẹ: Check and replace air filters in the indoor air handler every 1-3 months, or more frequently if needed. Dirty filters restrict airflow and reduce efficiency.
  • Isọmọ Ẹka ita gbangba: Keep the outdoor unit free from debris, leaves, and dirt. Periodically clean the coils with a soft brush or water hose (ensure power is off).
  • Eto Imuminu: Ensure the condensate drain line is clear and free of blockages to prevent water overflow.
  • Ayẹwo Ọjọgbọn: Schedule annual inspections and maintenance by a qualified HVAC technician.

8. Laasigbotitusita

This section provides solutions for common issues. For complex problems, contact a qualified HVAC technician.

  • Ko si Agbara: Check circuit breakers and ensure the disconnect switch is in the ON position.
  • Insufficient Heating/Cooling: Verify thermostat settings, check air filters for blockage, and ensure outdoor unit is not obstructed.
  • Awọn Ariwo Alailẹgbẹ: Minor operational noises are normal. Loud or unusual noises may indicate a problem requiring professional inspection.
  • Omi n jo: Check condensate drain line for blockages.

9. Awọn pato

Dimensions of ACiQ indoor and outdoor units

Nọmba 7: Image displaying the dimensions of both the indoor air handler unit (49.02" H x 21.02" W x 21.02" D) and the outdoor condensing unit (35.04" H x 37.24" W x 16.14" D).

Cooling capacity chart for ACiQ heat pump

Nọmba 8: Chart detailing the cooling capacity of the ACiQ system at various outdoor temperatures: 86°F (118% capacity), 95°F (113% capacity), 110°F (99% capacity), and 122°F (48% capacity).

Heating capacity chart for ACiQ heat pump

Nọmba 9: Chart detailing the heating capacity of the ACiQ system at various outdoor temperatures: -22°F (N/A), -13°F (41% capacity), 0°F (57% capacity), 17°F (70% capacity), and 32°F (73% capacity).

Ẹya ara ẹrọẸ̀kúnrẹ́rẹ́
Agbara Itutu31,000 BTU / wakati
Alapapo Agbara30,000 BTU/hr (at 47°F)
Oṣuwọn SEER218.8
Idiyele HSPF29.7
Iru RefrigerantR-454B
Abe ile Unit Power Ipese115/208/230V, 60Hz, 1Ph
Ita gbangba Unit Power Ipese208/230V, 60Hz, 1Ph
O pọju Piping Gigun164 ẹsẹ (mita 50)
Max Height Difference82 ẹsẹ (mita 25)
Indoor Unit Dimensions (W × D × H)21.02" × 21.02" × 49.02"
Outdoor Unit Dimensions (W × D × H)37.24" × 16.14" × 31.89"
Indoor Unit Net Weight128.97 lbs
Outdoor Unit Net Weight164.02 lbs

10. Atilẹyin ọja ati Support

ACiQ offers a comprehensive warranty for this heat pump system:

  • Atilẹyin ọja: ọdun meji 7
  • Atilẹyin ọja Compressor: ọdun meji 12

These warranty terms are valid when the system is installed by a certified technician and registered online with the manufacturer. For technical support, service inquiries, or warranty claims, please refer to the contact information provided in your product packaging or visit the official ACiQ webojula.

Awọn iwe aṣẹ ti o jọmọ - B0DHFF2DKL

Ṣaajuview AciQ 9K-24K Standard Heat Awọn ọna Agbegbe Nikan: Fifi sori & Afọwọṣe Oniwun
AciQ 9K-24K Standard Heat Single-Zone Systems Fifi sori & Afọwọṣe Oniwun. Itọsọna yii ṣe alaye fifi sori ẹrọ, iṣẹ ṣiṣe, ailewu, ati itọju fun awọn amúlétutù AciQ, pẹlu awọn pato awoṣe ati alaye refrigerant R454B.
Ṣaajuview AciQ Central Inverter Systems fifi sori Afowoyi
Atọwe fifi sori okeerẹ fun AciQ Central Inverter Air Conditioning and Heat Pump Systems, ṣe alaye awọn iṣọra ailewu, fifi sori ẹrọ itutu, fifi sori ẹrọ ita gbangba, wiwu, awọn pato agbara, imukuro afẹfẹ, ati awọn ilana ṣiṣe idanwo.
Ṣaajuview Olutọju Afẹfẹ Gige Odi ACiQ & Fifi sori ẹrọ Condenser Agbegbe Kanṣoṣo ti o gaju & Afọwọṣe Oniwun
Iwe afọwọkọ yii n pese alaye fifi sori ẹrọ, iṣẹ ṣiṣe, ati awọn itọnisọna ailewu fun awọn olutọju afẹfẹ ti o wa ni odi AciQ ati awọn condensers agbegbe kan ti o gbona pupọ, awọn awoṣe ibora ACIQ-06W-HH-MD nipasẹ ACIQ-24ZPL-HP230C.
Ṣaajuview AciQ Central Inverter Systems Ita gbangba Unit fifi sori Afowoyi
Comprehensive installation manual for ACiQ Central Inverter Systems outdoor units, covering safety precautions, refrigerant piping, wiring, unit installation, and testing procedures for models like ACiQ-18-AC, ACiQ-24-AC, ACiQ-18-EHPB, and others.
Ṣaajuview ACIQ Next Gen Ducted Heat fifa System: Awọn ọna Bẹrẹ Itọsọna fun Thermostat Wiring
Itọsọna yii n pese alaye pataki fun sisopọ ati wiwọn awọn iwọn otutu si AciQ Next Gen Ducted Heat Pump System. O ṣe alaye awọn iṣeduro iṣeduro ati awọn aṣayan asopọ miiran, pẹlu awọn eto iyipada DIP ati awọn atunto bulọọki ebute fun ọpọlọpọ awọn oriṣi iwọn otutu.
Ṣaajuview AciQ Awọn ibaraẹnisọrọ Mini-Split Air Handler & Fifi sori ẹrọ Condenser ati Afọwọṣe Oniwun
Comprehensive installation and owner's manual for ACiQ Essentials Mini-Split Air Handler and Condenser systems, covering safety precautions, parts identification, remote control operation, installation procedures, test runs, maintenance, and troubleshooting for various models. The manual also includes critical information regarding the servicing of systems using flammable refrigerant R454B, emphasizing safety protocols and regulatory compliance. It is designed for professional installers and end-users to ensure safe and efficient operation of ACiQ mini-split heat pump systems.