Comfort Direct RH787T / TR29 / CD787T

Ìwé Ìtọ́sọ́nà Olùlò Ìdarí Afẹ́fẹ́ Díẹ̀díẹ̀ fún Ìtùnú RH787T / TR29 DC Ceiling Remote Control

Model: RH787T / TR29 / CD787T

Àmì ìtajà: Comfort Direct

Ọrọ Iṣaaju

This manual provides comprehensive instructions for the installation, operation, and maintenance of your Comfort Direct RH787T / TR29 DC Ceiling Fan Remote Control. Please read this manual thoroughly before use to ensure proper function and longevity of your device.

Comfort Direct RH787T / TR29 DC Ceiling Fan Remote Control

Aworan: Iwaju view of the Comfort Direct RH787T / TR29 remote control, showing fan speed buttons (I-VI) and light control buttons.

Eto ati siseto

Follow these steps to set up and program your remote control with your DC ceiling fan.

1. Fi Batiri sii

The remote control requires one 23A/12V battery (not included). Open the battery compartment on the back of the remote and insert the battery, observing the correct polarity.

Battery compartment with dip switches

Image: Close-up of the remote control's battery compartment, showing the slot for the 23A/12V battery and the dip switches.

2. Ṣíṣe ètò lórí Latọna jijin rẹ

  1. Turn power off to the fan: Ensure the power supply to your ceiling fan is off. This can be done using an on/off switch on the wall or by switching off the circuit breaker for the fan.
  2. Hand turning off a wall light switch

    Image: A hand pressing a wall switch to the off position, illustrating the first step of turning off power to the fan.

  3. Set the dip switches: Locate the dip switches inside the battery compartment of your remote control. Set these switches to your desired code. Ensure the dip switches on the remote match the dip switches on your fan's receiver unit.
  4. Close-up of dip switches in battery compartment

    Aworan: A alaye view of the dip switches located within the remote control's battery compartment, ready for setting a code.

  5. Restore power and sync: Restore power to your fan. Within 1 minute of restoring power, press and hold the [Ṣeto] button located in the battery compartment for approximately 5 seconds.
  6. Hand turning on a wall light switch

    Image: A hand pressing a wall switch to the on position, indicating power restoration to the fan.

  7. Ìmúdájú: The red indicator light on the remote will blink twice, confirming that your fan is now synced to your remote control.

Awọn ilana Iṣiṣẹ

The RH787T / TR29 remote control provides intuitive control over your DC ceiling fan's functions.

Comfort Direct RH787T / TR29 DC Ceiling Fan Remote Control

Aworan: Iwaju view of the remote control, highlighting the various control buttons for fan speed and light.

  • Iṣakoso Iyara Fan: Àwọn bọ́tìnì tí a fi àmì sí I nipasẹ VI control the fan speed, with I being the lowest and VI being the highest setting.
  • Fan Tan/Pa a: The central button within the fan speed cluster typically controls the fan's power (on/off).
  • Iṣakoso ina: The lower set of buttons controls the fan's light. One button is for turning the light on/off, and the other is for dimming or brightening the light.

Itoju

Batiri Rirọpo

When the remote control's range decreases or the indicator light becomes dim, it is time to replace the battery. Open the battery compartment on the back of the remote and replace the old 23A/12V battery with a new one, ensuring correct polarity. Dispose of used batteries responsibly.

Laasigbotitusita

Refer to the following guide for common issues and their solutions regarding your remote control's indicator light.

Troubleshooting guide for remote control indicator light

Image: A graphic illustrating troubleshooting steps based on the behavior of the remote control's red indicator light.

Bad Remote Control SymptomsGood Remote Control Symptoms / Action
1. Red indicator light does not illuminate when buttons are pressed.1. Red indicator light only illuminates when buttons are pressed.
2. Red indicator light illuminates when no buttons are pressed.2. Red indicator light stays illuminated when you press and hold buttons.
3. Red indicator light stays illuminated at all times.DO NOT replace the remote control if you experience the symptoms in the right column. You may have a different problem with your fan.
Replace remote control if you experience any of the symptoms in the left column.

Awọn pato

BrandItunu Direct
Orukọ awoṣeCD787T (Compatible with RH787T / TR29)
Electric Fan DesignAja Fan
Orisun agbaraBattery Powered (Requires one 23A/12V battery)
Pataki ẸyaRadiofrequency (RF) Control
Voltage12 Volts (for battery)
inu ile / ita gbangba LiloNinu ile
Ọna IṣakosoLatọna jijin
Se Alailowaya bi?Bẹẹni
Nọmba ti Awọn ipele Agbara6 (Awọn iyara afẹfẹ)
Iwọn Nkan3.52 iwon
Package Mefa5.55 x 3.15 x 1.73 inches
UPC198715855975

Alaye atilẹyin ọja

This Comfort Direct RH787T / TR29 Remote Control comes with a 1 Odun olupese atilẹyin ọja. Please retain your proof of purchase for warranty claims. For specific terms and conditions, refer to the manufacturer's official webojula tabi kan si atilẹyin alabara.

Onibara Support

For further assistance, technical support, or to inquire about replacement parts, please visit the official Comfort Direct webaaye ayelujara tabi kan si ẹka iṣẹ alabara wọn. Awọn alaye olubasọrọ le ṣee ri lori apoti ọja tabi ti olupese webojula.

Awọn iwe aṣẹ ti o jọmọ - RH787T / TR29 / CD787T

Ṣaajuview Siemens SIMATIC HMI Comfort Panels Awọn ilana Ṣiṣẹ
Itọsọna alaye fun Siemens SIMATIC HMI Comfort Panels, fifi sori fifi sori ẹrọ, fifisilẹ, iṣẹ ṣiṣe, itọju, ati awọn alaye imọ-ẹrọ fun awọn awoṣe bii KP400, TP700, ati awọn miiran. Pẹlu awọn itọnisọna ailewu ati iṣeto ni eto.
Ṣaajuview Awọn ilana fifi sori ẹrọ: Amana/Goodman R9S96, D9S96, R9S92 Nikan-Stage Gas Furnaces
Awọn ilana fifi sori okeerẹ fun Amana ati Goodman nikan-stage gaasi ileru, awọn awoṣe R9S96, D9S96, ati R9S92. Ni wiwa awọn iṣọra ailewu, ohun elo ọja, awọn ibeere ipo, awọn imukuro, ijona ati fentilesonu, awọn ipo fifi sori ẹrọ, awọn ohun elo, fifi ọpa, awọn asopọ itanna, awọn ilana ibẹrẹ, laasigbotitusita, ati itọju.
Ṣaajuview Horizon Amọdaju Ergometer Bedienungsanleitung: Irorun Serie Modelle
Umfassende Anleitung fun Horizon Amọdaju Fahrradergometer der Comfort Serie (Comfort 3, 5i, 6i, 7i, 8i, Ri). Enthält Montage-, Sicherheits- und Bedienungshinweise sowie Trainingsprogramme.
Ṣaajuview Daikin DVT96 & RVT96 Meji-Stage Gas Furnace Awọn ilana fifi sori
Iwe ilana fifi sori osise fun Daikin's Amana ati Goodman DVT96 ati RVT96 meji-stage gaasi ileru. Awọn aabo aabo, fifi sori ẹrọ, fentilesonu, itanna, ati laasigbotitusita fun awọn alamọdaju HVAC.
Ṣaajuview Guide de Programmation Simplifiée Marantec pour Séries Comfort et Digital
Instructions détaillées pour la programmation des moteurs Marantec série Comfort et des télécommandes série Digital, incluant les réglages des fins de course, les positions intermédiaires et la configuration du digicode.
Ṣaajuview Venta Comfort Plus Luftbefeuchter Bedienungsanleitung
Umfassende Bedienungsanleitung fun Venta Comfort Plus Luftbefeuchter (LW15, LW25, LW45). Erfahren Sie mehr über Sicherheit, Inbetriebnahme, Funktionen, Reinigung und technische Daten für eine gesündere Raumluft.