HANMATEK HO51

Ìwé Ìtọ́sọ́nà Olùlò HANMATEK HO51 Oscilloscope, Multimeter, àti Waveform Generator 3-in-1

Model: HO51

1. Ifihan

The HANMATEK HO51 is a versatile, portable 3-in-1 device that integrates the functions of a digital oscilloscope, a multimeter, and a waveform generator. Designed for electronic troubleshooting, testing, and educational purposes, it offers a compact solution for various measurement needs. Its user-friendly interface and robust design make it suitable for both beginners and experienced professionals.

Awọn ẹya pataki:

  • 3-in-1 Iṣẹ-ṣiṣe: Combines an oscilloscope, multimeter, and waveform generator in a single compact unit.
  • Oscilloscope: 50 MHz bandwidth and 250 MS/s real-time sampling rate for precise waveform analysis.
  • Multimeter: Accurate measurements of voltage, current, resistance, capacitance, continuity, and diode tests.
  • Olupilẹṣẹ Waveform: Generates sine, square, triangle, and custom waveforms up to 1 MHz.
  • Apẹrẹ to gbe: Lightweight and compact (198mm x 100mm x 39mm, 0.5 kg) for easy transport and field use.
  • Ifihan: 3.5-inch color screen with an intuitive interface.
  • Ibamu Software PC: USB connectivity for data transfer and advanced control.
  • Agbara: Operates on battery or via USB power.
Diagram illustrating the 3-in-1 functionality of the HANMATEK HO51, showing separate displays for Oscilloscope, Multimeter, and Waveform Generator modes.

Image 1.1: The HANMATEK HO51's integrated Oscilloscope, Multimeter, and Waveform Generator functions.

2. Alaye Aabo

Please read all safety instructions carefully before operating the device. Failure to follow these instructions may result in electric shock, fire, or damage to the device.

  • Má ṣe lo ẹ̀rọ náà tí ó bá dà bíi pé ó ti bàjẹ́ tàbí tí kò bá ṣiṣẹ́ dáadáa.
  • Ensure proper probe connections and settings before taking measurements.
  • Má ṣe kọjá ìwọ̀n ìtẹ̀síwájú tó pọ̀ jùlọ fún ìpele ìpeletage ati lọwọlọwọ.
  • Use only the accessories provided or approved by HANMATEK.
  • Yẹra fun lilo ẹrọ naa ni ipo ti o tutu tabi tutuamp awọn ipo.
  • Disconnect power from the circuit under test before connecting or disconnecting probes.
  • Always observe local and national safety codes.

3. Package Awọn akoonu

Daju pe gbogbo awọn ohun ti a ṣe akojọ rẹ si isalẹ wa ninu package rẹ. Ti awọn ohun kan ba nsọnu tabi bajẹ, jọwọ kan si ataja rẹ.

  • HANMATEK HO51 Device
  • Okun USB (Iru-C)
  • Palolo Oscilloscope ibere
  • Awọn itọsọna Igbeyewo Multimeter
  • Quick Bẹrẹ Itọsọna
  • Probe Calibration Tool
  • Adapter agbara
  • Ọran Gbigbe Rirọ
Image showing the HANMATEK HO51 device along with all its included accessories: USB cable, oscilloscope probe, multimeter leads, power adapter, and carrying case.

Image 3.1: HANMATEK HO51 device and included accessories.

4. Ọja Ipariview

The HANMATEK HO51 features a clear layout for easy operation. Familiarize yourself with the buttons, connectors, and display area.

4.1 Iwaju Panel idari ati Ifihan

Detailed diagram of the HANMATEK HO51 front panel, labeling the display area, multi-function keys (F1-F4), Mode, CH, HOR, System, Save, Trig/Δ, Auto, Measure Range, Power Switch, Stop/Run, and Multimeter Input Ports.

Image 4.1: Front panel layout and controls of the HANMATEK HO51.

  • Agbegbe Ifihan: 3.5-inch color screen for waveform, measurement data, and menu display.
  • Awọn bọtini F1-F4: Multi-function keys, their purpose changes based on the current menu.
  • Bọtini ipo: Switches between Oscilloscope, Multimeter, and Waveform Generator modes.
  • CH Key: Channel selection (if applicable) or related settings.
  • HOR Key: Horizontal scale adjustment for oscilloscope.
  • Bọtini eto: Accesses system settings, including language selection.
  • Fipamọ́ Kọ́kọ́rọ́: Saves current waveform data or measurement results.
  • Kọ́kọ́rọ́ Tri/Δ: Trigger menu for oscilloscope or relative value key for multimeter.
  • Bọtini Aifọwọyi: Automatic setting for oscilloscope or automatic range key for multimeter.
  • Measure Range Key: Measurement menu for oscilloscope or range key for multimeter.
  • Bọtini Yipada Agbara: Yipada ẹrọ si tan/pa.
  • Bọtini Muu ṣiṣẹ/Daduro: Stops/runs oscilloscope acquisition or holds value for multimeter.
  • Awọn bọtini lilọ kiri: Up, Down, Left, Right for menu navigation and parameter adjustment.
  • Multimeter Input Ports: A, mA, COM, QVC for connecting multimeter test leads.

4.2 Side and Bottom Connectors

Images showing the side of the HANMATEK HO51 with the Type-C charging port, the rear with an expandable stand, and the device's silicone material and ABS jacket.

Aworan 4.2: Apa view showing Type-C charging port and rear stand.

  • Ibudo Ngba agbara Iru-C: Located on the side for charging the internal battery and USB communication with a PC.
  • Probe Compensation / Signal Generator Output Connector: Located on the top side, provides a 2.5V/1KHz square wave signal for probe calibration and serves as the waveform generator output.
  • Measured Signal Input Connector (BNC): Located on the bottom for connecting the oscilloscope probe.
  • Biraketi: An expandable stand on the back allows for convenient viewing awọn igun.

5. Eto

5.1 Gbigba agbara akọkọ

Before first use, fully charge the device using the provided USB Type-C cable and power adapter. The charging indicator will show the charging status.

5.2 Agbara Tan / Pa

Tẹ mọlẹ Power Yipada Key (a sábà máa ń fi àmì agbára sí i) láti tan tàbí pa ẹ̀rọ náà.

5.3 Language Yiyan

Upon first startup, the device may be in a default language. To change the language:

  1. Tẹ awọn Eto bọtini.
  2. Navigate to the language settings (often labeled F2 or similar).
  3. Select your desired language (e.g., English) using the navigation keys and confirm.

5.4 Oscilloscope Probe Calibration

For accurate oscilloscope measurements, calibrate the passive probe before use:

  1. Connect the oscilloscope probe to the BNC input connector on the bottom of the device.
  2. Connect the probe tip to the probe compensation/signal generator output connector (1KHz square wave) on the top side of the device.
  3. Enter Oscilloscope mode (if not already there) and adjust the vertical and horizontal scales to view the square wave.
  4. Using the small calibration tool, adjust the screw on the probe connector until the square wave displayed on the screen has flat tops and bottoms with sharp corners, indicating proper compensation.

6. Awọn ilana Iṣiṣẹ

6.1 Yipada Awọn ipo

Tẹ awọn Ipo key to cycle between Oscilloscope, Multimeter, and Waveform Generator functions.

6.2 Oscilloscope isẹ

In Oscilloscope mode, the device displays waveforms over time. Use the following controls:

  • Vertical Scale (Volts/Div): Adjust using the navigation keys (Up/Down) when the vertical scale is highlighted.
  • Horizontal Scale (Time/Div): Tẹ ORR. and then use navigation keys (Left/Right) to adjust.
  • Eto okunfa: Tẹ Ìlànà mẹ́ta/Δ to access trigger menu. Adjust trigger level, mode (Auto, Normal, Single), and type (rising/falling edge).
  • Eto Aifọwọyi: Tẹ Aifọwọyi for automatic waveform scaling and positioning.
  • Ṣiṣe/Duro: Tẹ awọn Ṣiṣẹ / Sinmi key to start or stop waveform acquisition.

6.3 Multimeter isẹ

In Multimeter mode, the device performs various electrical measurements. Connect the multimeter test leads to the appropriate input ports (A, mA, COM, QVC).

  • Aṣayan iṣẹ-ṣiṣe: Use the F1-F4 keys or navigation keys to select measurement functions (Voltage, Current, Resistance, Capacitance, Continuity, Diode).
  • Aṣayan Ibiti: Tẹ Iwọn Iwọn to manually select the measurement range, or use Aifọwọyi for automatic ranging.
  • Idanwo Ilọsiwaju: Connect leads across a circuit. An audible tone indicates continuity. Note that some users have reported a slight delay in response for continuity tests.
  • Idanwo Diode: Connect leads across a diode to measure its forward voltage ju.

6.4 Waveform Generator Operation

In Waveform Generator mode, the device outputs various signals from the probe compensation/signal generator output connector.

  • Iru igbi igbi: Use the F1-F4 keys or navigation keys to select the desired waveform (Sine, Square, Triangle, Pulse).
  • Atunse Igbohunsafẹfẹ: Adjust the output frequency using the navigation keys.
  • AmpÀtúnṣe litude: Ṣatunṣe abajade amplitude (1Vpp or 2.5Vpp) using the navigation keys.

6.5 PC Software Connectivity

Connect the HO51 to a computer via the USB Type-C port. Compatible PC software allows for data transfer, waveform analysis, and remote control of the device. Refer to the software's documentation for detailed instructions.

Image showing the HANMATEK HO51 connected to a laptop via USB, demonstrating data transfer and PC software compatibility for waveform analysis.

Image 6.1: HANMATEK HO51 connected to a PC for data export and analysis.

7. Itọju

Proper maintenance ensures the longevity and accuracy of your HANMATEK HO51.

  • Ninu: Lo asọ, damp cloth to clean the device. Do not use abrasive cleaners or solvents. Ensure the device is powered off and disconnected from any power source before cleaning.
  • Ibi ipamọ: Store the device in a cool, dry place, away from direct sunlight and extreme temperatures. Use the provided carrying case for protection.
  • Itọju Batiri: Fún ìgbà tí batiri bá pẹ́ tó, má ṣe jẹ́ kí batiri náà máa jáde dáadáa nígbà gbogbo. Tí o bá ń tọ́jú rẹ̀ fún ìgbà pípẹ́, gba agbára bátiri náà sí nǹkan bí 50% ní gbogbo oṣù díẹ̀.
  • Awọn imudojuiwọn famuwia: Periodically check the HANMATEK official website for available firmware updates to ensure optimal performance and access to new features.

8. Laasigbotitusita

If you encounter issues with your HANMATEK HO51, refer to the following common problems and solutions.

  • Ẹrọ ko ni agbara lori:
    • Ensure the battery is charged. Connect the device to a power source using the USB-C cable and adapter.
    • Tẹ mọlẹ bọtini agbara fun iṣẹju diẹ.
  • Kò sí ìgbì ìgbì tí a fihàn nínú ipò Oscilloscope:
    • Check if the probe is correctly connected to the BNC input.
    • Verify the probe is properly calibrated.
    • Adjust the vertical (Volts/Div) and horizontal (Time/Div) scales.
    • Check trigger settings; try setting the trigger mode to 'Auto' or adjusting the trigger level.
    • Ensure the 'Run' state is active (not paused).
  • Multimeter readings are inaccurate or slow:
    • Ensure test leads are securely connected to the correct input ports.
    • Verify the correct measurement function and range are selected.
    • For continuity tests, allow a moment for the device to register the connection, as some users have noted a slight delay.
    • Consider performing a factory reset via the System menu if persistent issues occur.
  • Waveform generator output is incorrect:
    • Ensure the output is connected to the correct port.
    • Verify the selected waveform type, frequency, and amplitude eto.

9. Awọn pato

Detailed technical specifications for the HANMATEK HO51 device.

9.1 Àwọn Àlàyé Oscilloscope

Ẹya ara ẹrọApejuwe
ikanni1
Bandiwidi50 MHz
Ipinnu Inaro8 die-die
Sampling ỌnaSampling, Peak Detection
Akoko gidi SampOṣuwọn ling250 MS/s
Waveform Refresh Rate10,000 wfms/s
Akoko Mimọ Yiye± 100ppm
Input IsopọmọraDC, AC, GND
Iwadii Attenuation1X, 10X, 100X, 1000X, 10000X
O pọju Input Voltage400V (DC+AC, PK-PK)
Ipo okunfaAifọwọyi, Deede, Nikan
Orisi okunfaEtí Gíga, Etí Ṣíṣubú
Ọna asopọAC / DC

9.2 Àwọn Ìlànà Onímílítà Púpọ̀

Ẹya ara ẹrọApejuwe
Digital IfihanAwọn iṣiro 24,000
Orisi wiwọnVoltage, Current, Resistance, Capacitance, Continuity, Diode
O pọju Input VoltageAC: 750V, DC: 1000V
Iṣawọle ti o pọju lọwọlọwọAC: 10A, DC: 10A
Igbeyewo Ilọsiwaju< (50Ω)
Idanwo Diode< (0-2V)
Aifọwọyi RangeBẹẹni
TRMSBẹẹni

9.3 Waveform Generator Specifications

Ẹya ara ẹrọApejuwe
Waveform Frequencies (Sine)10Hz ~ 100 kHz
Waveform Frequencies (Square)10Hz ~ 100 kHz
Waveform Frequencies (Ramp)10Hz ~ 100 kHz
Waveform Frequencies (Pulse)10Hz ~ 10 kHz
Amplitude1Vpp or 2.5Vpp

9.4 Gbogbogbo Awọn alaye

Ẹya ara ẹrọApejuwe
Batiri1 Litiọmu-polyma (tí ó wà pẹ̀lú rẹ̀)
Awọn iwọn Ọja (L x W x H)23 x 13.5 x 7.5 cm
Iwọn410 giramu
Nọmba awoṣeHO51
BrandHANMATEK
Orisun agbaraBatiri agbara
Àwọ̀Buluu
IbamuCE

10. Atilẹyin ọja ati Support

For warranty information, technical support, or service inquiries, please refer to the documentation included with your product or contact HANMATEK customer service directly. You may also visit the product page on Amazon for additional support resources or to contact the seller.

Oju-iwe ọja Amazon: HANMATEK HO51 on Amazon.com.be

Awọn iwe aṣẹ ti o jọmọ - HO51

Ṣaajuview HANMATEK HO Nikan ikanni Series Amusowo Oscilloscope olumulo Afowoyi
Itọsọna olumulo pipe fun HANMATEK HO Single Channel Series amusowo oscilloscope, ibora alaye aabo, iṣẹ ṣiṣe, awọn alaye imọ-ẹrọ, ati laasigbotitusita.
Ṣaajuview HANMATEK HO50 Series Amusowo Oscilloscope, Multimeter, ati Waveform monomono
Ṣe afẹri HANMATEK HO50 Series 2-CH Amusowo Oscilloscope, ohun elo 3-in-1 to wapọ ti o n ṣajọpọ oscilloscope, multimeter, ati olupilẹṣẹ igbi. Apẹrẹ fun itọju ita gbangba, awọn wiwọn lori aaye, ati awọn iwadii ọkọ ayọkẹlẹ, ti o ni ifihan LCD giga-iwọn 3.5-inch, igbesi aye batiri gigun, ati asopọ USB Iru-C.
Ṣaajuview Hanmatek HO11 Amusowo Oscilloscope olumulo Afowoyi
Itọsọna olumulo pipe fun Hanmatek HO11 oscilloscope amusowo, ṣe alaye awọn ẹya rẹ, iṣẹ ṣiṣe, ati awọn alaye imọ-ẹrọ. Kọ ẹkọ bi o ṣe le lo ẹrọ naa fun ọpọlọpọ awọn oju iṣẹlẹ wiwọn itanna.
Ṣaajuview Hanmatek DOS1102 Digital Ibi Oscilloscope Quick Itọsọna
Itọsọna iyara si Hanmatek DOS1102 Digital Ibi Oscilloscope, ibora awọn iṣọra ailewu, iwaju ati awọn apejuwe nronu iwaju, awọn iṣẹ agbegbe iṣakoso, wiwo olumulo, ati awọn iṣẹ ipilẹ bii isanpada iwadii ati awọn wiwọn adaṣe.
Ṣaajuview Ìtọ́sọ́nà Kíákíá fún HANMATEK DOS1102 Ìpamọ́ Oní-nọ́ńbà
Bẹ̀rẹ̀ kíákíá pẹ̀lú HANMATEK DOS1102 Digital Storage Oscilloscope. Ìtọ́sọ́nà kíákíá yìí bo àwọn ìwífún nípa ààbò pàtàkì, àwọn àpèjúwe iwájú/ẹ̀yìn, ìfọwọ́sowọ́pọ̀ olùlò, àwọn iṣẹ́ ìpìlẹ̀, àti ìbánisọ̀rọ̀ PC.
Ṣaajuview HANMATEK DOS1104 Digital Storage Oscilloscope User Manual
User manual for the HANMATEK DOS1104 Digital Storage Oscilloscope. Provides detailed information on safety, operation, front/rear panel controls, user interface, probe setup, calibration, vertical/horizontal/trigger systems, automatic measurements, PC communication, and technical specifications.