AC Infinity AI-ACS6

AC Infinity AIRCOM S6 12-inch Rear-Exhaust Cooling Blower Fan System User Manual

Model: AI-ACS6

1. Ifihan

This manual provides comprehensive instructions for the installation, operation, and maintenance of your AC Infinity AIRCOM S6 12-inch Rear-Exhaust Cooling Blower Fan System. This system is designed to efficiently cool various audio/video (AV) components, including receivers, amplifiers, DVRs, and gaming consoles, preventing overheating and extending their lifespan.

AC Infinity AIRCOM S6 Cooling Blower Fan System, front view

Figure 1: AC Infinity AIRCOM S6 unit, front view, ifihanasing awọn oniwe-aso oniru ati iṣakoso nronu.

2. Alaye Aabo

Please read all safety instructions before operating this product to prevent injury or damage. Keep this manual for future reference.

  • Rii daju pe ipese agbara voltage baamu awọn ibeere ọja naa.
  • Ma ṣe fi ẹrọ naa han si omi tabi ọrinrin pupọ.
  • Avoid blocking the fan intake or exhaust vents to ensure proper airflow.
  • Má ṣe gbìyànjú láti tú tàbí tún ẹ̀rọ náà ṣe fúnra rẹ. Tọ́ka sí àwọn òṣìṣẹ́ iṣẹ́ tó péye.
  • Jeki ẹrọ kuro ni awọn orisun ooru ati oorun taara.

3. Package Awọn akoonu

Daju pe gbogbo awọn nkan wa ninu apo rẹ:

  • AC Infinity AIRCOM S6 Unit (1)
  • Adaparọ agbara (1)
  • Ilana itọnisọna (1)

4. Ọja Ipariview

The AIRCOM S6 is a quiet cooling blower fan system designed for rear-exhaust applications. It features intelligent programming and a low-profile oniru.

Diagram showing AC Infinity AIRCOM S6 placed on top of an AV receiver with an upward blue arrow indicating airflow

Figure 2: The AIRCOM S6 positioned above an AV receiver, illustrating its function as a component cooling system to prevent overheating.

Awọn ẹya pataki:

  • Isẹ idakẹjẹ: Utilizes dual-ball bearing blowers with PWM-controlled motors for minimal noise output.
  • Siseto oye: Offers two thermal trigger modes and four speed control options for customized cooling.
  • Rear-Exhaust Design: Specifically configured to exhaust hot air from the rear of AV components.
  • Pro kekerefile: Designed with a slim 1.5-inch height for placement in tight spaces or stacking with other components.
Close-up of the AC Infinity AIRCOM S6 control panel showing buttons for mode, power, and fan speed

Nọmba 3: Alaye view of the control panel, highlighting the intelligent programming features including multiple program modes, temperature trigger settings, and four fan speeds.

5. Eto

Follow these steps to set up your AIRCOM S6 cooling system:

  1. Ibi: Position the AIRCOM S6 directly on top of the AV component you wish to cool. Ensure the rear exhaust vents are not obstructed. For optimal performance, place the unit where it can draw air from the component's vents and exhaust it freely.
  2. Asopọ agbara: Connect the included power adapter to the unit's power input port. Plug the power adapter into a standard electrical outlet.
  3. Agbara Ibẹrẹ Tan: The unit will power on automatically or can be turned on using the power button on the control panel.
AC Infinity AIRCOM S6 unit placed on top of an AV receiver inside a wooden cabinet

Figure 4: The AIRCOM S6 integrated into an entertainment cabinet, demonstrating typical placement above an AV component.

6. Awọn ilana Iṣiṣẹ

The AIRCOM S6 features a control panel for adjusting settings. Refer to Figure 3 for control panel layout.

6.1. Agbara Tan / Paa

Press the power button (usually the central button) to turn the unit on or off.

6.2. Fan Speed ​​Iṣakoso

The unit offers four fan speed settings, ranging from silent to powerful. Use the fan speed button (typically on the right) to cycle through the available speeds. Higher speeds provide more airflow but may produce slightly more noise.

6.3. Thermal Trigger Modes

The AIRCOM S6 includes two thermal trigger modes. These modes allow the fan to automatically adjust its speed or turn on/off based on detected temperature. Consult the detailed product manual for specific instructions on setting temperature thresholds and mode selection.

6.4. Agbara Outage Iranti

The system retains its last settings in the event of a power outage, resuming operation with the previously selected mode and speed once power is restored.

7. Itọju

Regular maintenance ensures optimal performance and longevity of your AIRCOM S6 unit.

  • Ninu: Periodically clean the fan grilles and exterior surfaces with a soft, dry cloth. Do not use abrasive cleaners or solvents.
  • Yiyọ eruku kuro: Use a can of compressed air to gently clear dust from the fan blades and internal components through the grilles. Ensure the unit is powered off and unplugged before cleaning.
  • Ayewo: Regularly check the power cord and adapter for any signs of damage.

8. Laasigbotitusita

If you encounter issues with your AIRCOM S6, refer to the table below for common problems and solutions.

Isoro Owun to le Fa Ojutu
Ẹka ko ni agbara lori. No power, faulty adapter, or unit malfunction. Check power outlet. Ensure power adapter is securely connected. Try a different outlet. If problem persists, contact support.
Àwọn afẹ́fẹ́ kò yípo. Unit is off, fan speed set to zero, or thermal trigger not met. Ensure unit is powered on. Increase fan speed. Check thermal trigger settings if in auto mode.
Unit is making unusual noise. Obstruction in fan, excessive dust, or fan bearing issue. Power off and unplug the unit. Carefully inspect for obstructions. Clean dust from fans. If noise persists, contact support.
Itutu agbaiye ti ko to. Low fan speed, blocked vents, or improper placement. Increase fan speed. Ensure component and unit vents are clear. Adjust placement for better airflow.

9. Awọn pato

Technical details for the AC Infinity AIRCOM S6:

  • Awoṣe: AI-ACS6
  • Awọn iwọn (L x W x H): 11.6" x 6.3" x 1.5" (29.5 cm x 16.0 cm x 3.8 cm)
  • Exhaust Direction: Ẹyìn
  • Fife ategun: 100 CFM (Ẹsẹ onigun fun iṣẹju kan)
  • Ipele Ariwo: 20 dBA (Decibels, A-weighted)
  • Lilo Agbara: 5.2 Wattis
  • Irú Fan: Dual-ball bearing blowers
  • Ohun elo: Alloy Irin
  • Awọn ẹrọ ibaramu: Awọn olugba, Amplifiers, DVRs, Gaming Consoles, and other AV components.
Diagram showing the dimensions and key specifications of the AC Infinity AIRCOM S6

Figure 5: Visual representation of the AIRCOM S6 dimensions and core specifications.

10. Atilẹyin ọja ati Support

AC Infinity products are designed with quality and durability in mind. For warranty information and customer support, please visit the official AC Infinity webojula tabi kan si wọn onibara iṣẹ Eka.

  • Osise Webojula: www.acinfinity.com
  • Olubasọrọ Support: Tọkasi awọn website for contact methods, including email and phone support.

Please have your model number (AI-ACS6) and purchase date available when contacting support.

Awọn iwe aṣẹ ti o jọmọ - AI-ACS6

Ṣaajuview AC Infinity AIRCOM Series Component Cooling System User Manual
User manual for the AC Infinity AIRCOM Series component cooling systems, detailing product features, requirements, setup, programming, FAQs, and warranty information. Includes model numbers and specifications for AIRCOM S and T series.
Ṣaajuview AC Infinity AIRCOM Series Component Cooling System User Manual
User manual for the AC Infinity AIRCOM Series Component Cooling System. Learn about product requirements, key features, setup, programming, and troubleshooting for models like AIRCOM S6, S7, S8, S9, S10, T8, T9, and T10. Includes warranty information and contact details.
Ṣaajuview AC Infinity AIRCOM Series Component Cooling System User Manual
User manual for the AC Infinity AIRCOM Series component cooling systems, detailing product requirements, features, setup, programming, other products, and warranty information.
Ṣaajuview Ìwé Ìtọ́sọ́nà Olùlò fún Àwọn Fẹ́ẹ̀bù Ìtura AC Infinity Axial Series
Comprehensive user manual for AC Infinity Axial Series project cooling fans. Covers product specifications, key features, contents, fan replacement, mounting, powering, speed controller operation, other AC Infinity products, and warranty information.
Ṣaajuview Ìwé Ìtọ́sọ́nà Olùlò fún Ètò Ìtutù AC Infinity AIRCOM Series | Cinema Oní-nọ́ńbà
User manual for the AC Infinity AIRCOM Series component cooling systems, available at Digital Cinema. Learn how to set up, program, and utilize features for optimal performance of your audio-video equipment.
Ṣaajuview AC Infinity AIRCOM Series Component Cooling System User Manual
User manual for AC Infinity's AIRCOM Series component cooling systems, covering setup, features, programming, and FAQs for models like AIRCOM S6, S7, S8, S9, S10, T8, T9, and T10. Essential guide for optimizing AV equipment cooling.