Frigga M2H

Ìwé Ìtọ́sọ́nà Olùlò Olùkọ̀wé Ìwádìí Dátà Frigga M2H

Model: M2H

1. Ifihan

The Frigga M2H is a reusable USB digital data logger designed for monitoring and recording temperature and humidity. It is ideal for applications requiring precise environmental tracking, such as in food, pharmaceutical, and laboratory settings. This manual provides essential information for the proper setup, operation, and maintenance of your Frigga M2H data logger.

Frigga M2H Data Logger

Figure 1: Frigga M2H Reusable Temperature Humidity Data Logger. This image shows the compact design of the data logger with its USB connector exposed.

1.1. Ohun ti o wa ninu Apoti

2. Ọja Ipariview

Familiarize yourself with the components of the Frigga M2H data logger.

Frigga M2H Data Logger Components

Figure 2: Key components of the Frigga M2H Data Logger. This diagram labels the USB Cover, USB Connector, LED Indicator, LCD Screen, Stop Button, Start Button, and Bar Code Label.

3. Eto

3.1. Software Installation (Frigga Data Software)

While the Frigga M2H can generate PDF/CSV reports directly, the companion Frigga Data Software offers advanced configuration and analysis capabilities. This software is compatible with Windows and Mac OS.

  1. Download the Frigga Data Software from the official Frigga webojula.
  2. Fi software naa sori kọmputa rẹ ni atẹle awọn ilana loju iboju.
  3. Connect the Frigga M2H data logger to your computer's USB port.
  4. Launch the Frigga Data Software. The device should be recognized automatically.

3.2. Iṣeto ni ibẹrẹ

Using the Frigga Data Software, you can customize various logging parameters:

Frigga Data Center Software Interface

Figure 3: Parameter settings within the Frigga Data Center software. This image displays the software interface where users can configure settings such as temperature units, alarm ranges, and logging intervals.

After configuring, save the settings to the device through the software.

4. Awọn ilana Iṣiṣẹ

4.1. Starting Data Logging

To begin recording data, press and hold the BERE button for approximately 5 seconds until the LED indicator confirms logging has started (e.g., a green flash or specific icon on the LCD). If a delayed start was configured, logging will commence after the set delay.

4.2. Stopping Data Logging

To stop recording data, press and hold the DURO button for approximately 5 seconds until the LED indicator confirms logging has ceased. Data logging will also stop automatically if the memory is full or the battery is depleted.

4.3. Exporting Data Reports

The Frigga M2H offers two primary methods for data export:

Automatic PDF and CSV Report Generation

Figure 4: Auto-generated PDF and CSV reports. This image illustrates that the data logger can directly generate PDF and CSV files when connected to a computer, without requiring additional software.

  1. Direct USB Report Generation:
    • Connect the data logger to any computer's USB port.
    • The device will appear as a removable drive.
    • Automatically generated PDF and CSV reports containing the recorded data will be available on this drive. No special software is required for this method.
  2. Frigga Data Software Export:
    • Connect the data logger to a computer with the Frigga Data Software installed.
    • Open the software and select the connected device.
    • The software allows for charting, statistical analysis, and export of data to various formats, including Excel and PDF.

5. Awọn pato

Key technical specifications for the Frigga M2H data logger:

Frigga M2H Product Parameters

Figure 5: Detailed product parameters for the Frigga M2H. This image outlines the measurement ranges, accuracy ranges for both temperature and humidity, and physical dimensions.

ParamitaIye
Measurement Range (Temperature)-30°C ~ +70°C (-22°F ~ +158°F)
Measurement Range (Humidity)5% ~ 95% RH
Accuracy Range (Temperature)±0.5℃ (-20℃ ~ +40℃); ±1℃ for other ranges
Accuracy Range (Humidity)±3% (20% ~ 80% RH); ±5% for other ranges
Data Memory Agbara14,400 kika
Batiri IruCR2450 (pẹlu)
Mabomire iteIP65
Awọn iwọnApproximately 4.41 inches (H) x 1.85 inches (W)
Iwuwo (fun ikankan)Isunmọ. 72.6g
Pataki Awọn ẹya ara ẹrọAlarm, Fast Reading System, High Accuracy

6. Itọju

6.1. Batiri Rirọpo

The Frigga M2H data logger uses a replaceable CR2450 battery, ensuring long-term usability. Follow these steps to replace the battery:

Steps for Frigga M2H Battery Replacement

Figure 6: Illustrated guide for replacing the CR2450 battery in the Frigga M2H data logger. The steps show opening the battery compartment, removing the old battery, and inserting a new one.

  1. Wa ideri iyẹwu batiri ni ẹhin ẹrọ naa.
  2. Use a coin or a suitable tool to twist the cover counter-clockwise to unlock it.
  3. Fi ìṣọ́ra yọ batiri CR2450 àtijọ́ náà kúrò.
  4. Fi batiri CR2450 titun sii pẹlu ẹgbẹ rere (+) ti nkọju si oke.
  5. Replace the cover and twist clockwise to secure it.

6.2. Waterproofing

The Frigga M2H data logger features an IP65 waterproof rating, meaning it is protected against dust ingress and low-pressure water jets from any direction. This makes it suitable for use in environments where it may be exposed to splashes or dust.

Frigga M2H IP65 Waterproof Rating

Figure 7: The Frigga M2H data logger demonstrating its IP65 waterproof capability. This image shows the device being splashed with water, highlighting its durability in challenging environments.

Ensure the USB cover is securely closed to maintain the IP65 rating. The device is not designed for submersion in water.

7. Laasigbotitusita

7.1. Software Compatibility Issues

Some users may experience compatibility issues with the Frigga Data Software, particularly on certain operating systems or versions (e.g., Mac OS or newer Windows versions). If you encounter problems:

7.2. Data Logger Not Starting/Stopping

8. Atilẹyin ọja ati Support

Frigga provides technical support for its products. If you encounter any issues or have questions not covered in this manual:

Awọn iwe aṣẹ ti o jọmọ - M2H

Ṣaajuview Iwọn otutu FRIGGA V5 ati Itọsọna olumulo Logger Data ọriniinitutu
Itọsọna olumulo fun iwọn otutu FRIGGA V5 ati Logger Data ọriniinitutu, ṣe alaye awọn ẹya rẹ, iṣẹ ṣiṣe, iṣeto, ati awọn iṣẹ ijabọ fun awọn eekaderi pq tutu.
Ṣaajuview Iwọn otutu FRIGGA V5 Plus & Afọwọṣe olumulo Data Logger Ọriniinitutu
Iwe afọwọkọ olumulo okeerẹ fun iwọn otutu FRIGGA V5 Plus ati logger data ọriniinitutu. Kọ ẹkọ bi o ṣe le ṣeto, ṣiṣẹ, ati gba data pada lati ọdọ logger rẹ fun ibojuwo pq tutu.
Ṣaajuview Frigga 4G & Wi-Fi 6 Ilana olumulo Multisensor gidi-akoko
Iwe afọwọkọ olumulo fun Frigga 4G & Wi-Fi 6 Multisensor-Time Real-Time (Awoṣe S0), ṣe alaye awọn ẹya rẹ, awọn akoonu package, ọja ti pariview, Awọn ilana iṣeto, Itọsọna Atọka LED, awọn alaye imọ-ẹrọ, gbigbe ẹrọ, alaye batiri, awọn igbesẹ laasigbotitusita, ati ibamu FCC.
Ṣaajuview Afọwọṣe olumulo ile-iṣẹ data Frigga V 1.0.0
Itọsọna olumulo pipe fun sọfitiwia Ile-iṣẹ Data Frigga, itọsọna awọn olumulo nipasẹ fifi sori ẹrọ, iṣakoso data, iṣeto ẹrọ, awọn iṣẹ awọsanma, ati awọn ẹya ibamu fun ibojuwo pq tutu.
Ṣaajuview Sensọ Smart FRIGGA S0: Ilana itọnisọna ati Itọsọna iṣeto
Awọn ilana alaye fun eto ati ṣiṣiṣẹ sensọ Smart FRIGGA S0. Ni wiwa awọn ẹya ọja, igbasilẹ app, iforukọsilẹ akọọlẹ, asopọ ẹrọ, iṣeto Wi-Fi, ati awọn eto paramita. Pẹlu alaye ibamu FCC.
Ṣaajuview Frigga SV2 Series Smart Active Data Logger User Manual
User manual for the Frigga SV2 Series Smart Active Data Logger, detailing appearance, display functions, operation steps, usage scenarios, and FCC compliance.