1. Ifihan
This user manual provides detailed instructions for the operation and maintenance of the Temtop PMD371 and Airing2000 Professional Air Quality Monitoring Bundle. This bundle offers a comprehensive solution for precise particle and air quality monitoring in various environments, including laboratories, cleanrooms, and field applications. The PMD371 is designed for detailed particle detection and environmental monitoring, while the Airing2000 extends capabilities with advanced particulate and formaldehyde detection. Please read this manual thoroughly before using the devices to ensure proper function and safety.
2. Alaye Aabo
- Do not expose the devices to extreme temperatures, humidity, or direct sunlight.
- Yago fun jisilẹ tabi fifi awọn ẹrọ si awọn ipa to lagbara.
- Do not attempt to disassemble or modify the devices. Refer all servicing to qualified personnel.
- Keep the devices away from water and other liquids.
- Rí i dájú pé afẹ́fẹ́ ń yọ́ dáadáa nígbà tí o bá ń ṣiṣẹ́ ní àwọn ibi tí a ti pamọ́ sí.
- Use only the specified power adapters and accessories provided by Temtop.
3. Package Awọn akoonu
Jẹrisi pe gbogbo awọn ohun kan wa ninu package:
- Temtop PMD371 Particle Counter
- Temtop Airing2000 Particulate Monitor
- USB Charging Cables (x2)
- Awọn oluyipada agbara (x2)
- Afowoyi Olumulo (iwe-ipamọ yii)
- Calibration Certificate (if applicable)
4. Ọja Ipariview

Image: The Temtop PMD371 (right) and Airing2000 (left) air quality monitors, showcasing their distinct designs and displays.

Aworan: Iwaju view of the Temtop PMD371 Particle Counter, highlighting its display and control buttons.

Aworan: Iwaju view of the Temtop Airing2000 Particulate Monitor, showing its ergonomic design and display.
4.1 Temtop PMD371 Particle Counter
The PMD371 is a precision instrument designed for multi-size particle detection and environmental monitoring. It features a robust all-metal construction for durability and reliable data collection.
- Iboju ifihan: Shows real-time particle counts (0.3µm, 0.5µm, 1.0µm, 2.5µm, 5.0µm, 10.0µm), PM2.5, PM10, temperature, and humidity.
- Bọtini agbara: Yipada ẹrọ si tan/pa.
- Awọn bọtini iṣẹ: Navigation and selection for various modes and settings.
- Ibudo Wiwọle: Where air samples are drawn in for analysis.
- Ibudo USB: Fun gbigba agbara ati gbigbe data.

Image: The Temtop PMD371 highlighting its durable all-metal casing, ensuring robust performance.

Image: The Temtop PMD371 illustrating its compact size (170 x 110 x 48 mm) and lightweight design (1.76 lbs), emphasizing its portability.
4.2 Temtop Airing2000 Particulate Monitor
The Airing2000 is designed for comprehensive field monitoring, providing accurate measurements of PM2.5, PM10, TSP, temperature, humidity, and formaldehyde.
- Iboju ifihan: Shows real-time readings for PM2.5, PM10, TSP, temperature, humidity, and HCHO.
- Bọtini agbara: For turning the device on/off.
- Awọn bọtini lilọ kiri: Fun lilọ kiri akojọ aṣayan ati awọn atunṣe eto.
- Wiwọle/Olugbafẹfẹ: Ports for air sampling.
- Ibudo gbigba agbara: Fun gbigba agbara ti abẹnu batiri.

Image: The Temtop Airing2000 showcasing its enterprise-grade precision, industrial-grade pumping sensor, comprehensive monitoring, instant data access, user-friendly operation, and portable design.

Image: The Temtop Airing2000 demonstrating its comprehensive monitoring capabilities, including particulate concentration (PM2.5, PM10, TSP), particle count (0.3µm, 0.5µm, 1.0µm), and environmental conditions (temperature, humidity).

Aworan: A alaye view of the Temtop Airing2000's internal pump-suction sensor, highlighting its advanced optics and wide particle size detection capabilities.
5. Eto
5.1 Gbigba agbara akọkọ
Before first use, fully charge both the PMD371 and Airing2000 devices. Connect the provided USB charging cables to the respective devices and plug them into the power adapters. A full charge typically takes 3-4 hours. The battery indicator on the screen will show charging status.
5.2 Titan / Pa a
- Lati fi agbara tan: Tẹ mọlẹ Agbara bọtini titi iboju illuminates.
- Lati fi agbara si pipa: Tẹ mọlẹ Agbara bọtini titi iboju yoo wa ni pipa.
5.3 Ipilẹ Eto
Upon first power-on, you may need to set the date, time, and preferred units. Navigate through the menu using the arrow buttons and confirm selections with the OK bọtini.
- Ọjọ & Akoko: Set current date and time for accurate data logging.
- Awọn ẹya: Select preferred units for temperature (°C/°F) and particulate matter (µg/m³).
6. Awọn ilana Iṣiṣẹ
6.1 Taking Measurements with PMD371
- Ibi: Position the PMD371 in the area you wish to monitor. Ensure the air inlet is unobstructed.
- Ibẹrẹ Iwọn: Tẹ awọn Bẹrẹ/Duro button to begin continuous monitoring. The screen will display real-time particle counts and environmental data.
- Interpreting Readings:
- Particle Counts: Displays the number of particles per liter for various sizes (0.3µm, 0.5µm, 1.0µm, 2.5µm, 5.0µm, 10.0µm).
- PM2.5/PM10: Shows the concentration of particulate matter in micrograms per cubic meter (µg/m³).
- Iwọn otutu/Ọriniinitutu: Displays ambient temperature and relative humidity.
- Stop Measurement: Tẹ awọn Bẹrẹ/Duro button again to pause or stop monitoring.
- Gbigba data: The device automatically logs data. You can access historical data through the menu.

Image: The Temtop PMD371's screen displaying detailed particle count data for various sizes (0.3µm, 0.5µm, 0.7µm, 1.0µm, 2.5µm, 5.0µm, 10.0µm) and PM2.5/PM10 concentrations.
6.2 Taking Measurements with Airing2000
- Ibi: Hold the Airing2000 or place it in the desired monitoring location. Ensure the air inlet is clear.
- Ibẹrẹ Iwọn: The device typically starts measuring automatically upon power-on. Observe the real-time readings on the display.
- Interpreting Readings:
- PM2.5/PM10/TSP: Displays concentrations of various particulate matters.
- HCHO: Shows formaldehyde concentration.
- Iwọn otutu/Ọriniinitutu: Displays ambient temperature and relative humidity.
- Isakoso data: Use the navigation buttons to review historical data or adjust settings.
6.3 Data Transfer and Analysis
Both devices support data export. Connect the devices to a computer using the provided USB cables. The devices will appear as a removable storage device, allowing you to access logged data files (e.g., CSV format) for further analysis using spreadsheet software.
7. Itọju
7.1 Ninu
- Wipe the exterior of the devices with a soft, dry cloth.
- Ma ṣe lo awọn olutọpa abrasive, awọn nkanmimu, tabi awọn kemikali to lagbara.
- Ensure the air inlet and outlet ports are free from dust and debris. Use a soft brush or compressed air if necessary, but avoid forcing anything into the ports.
7.2 Ibi ipamọ
- Tọ́jú àwọn ẹ̀rọ náà sí ibi tí ó tutù tí ó sì gbẹ, kúrò níbi tí oòrùn kò ti lè tàn án tàbí ibi tí ó gbóná jù.
- If storing for an extended period, ensure the batteries are partially charged (around 50%) to prolong battery life. Recharge every 3-6 months.
7.3 Idiwọn
The devices are factory calibrated. For professional applications requiring high accuracy, periodic re-calibration by authorized service centers is recommended. Refer to Temtop's official webaaye tabi kan si atilẹyin alabara fun awọn iṣẹ isọdọtun.
8. Laasigbotitusita
| Isoro | Owun to le Fa | Ojutu |
|---|---|---|
| Ẹrọ naa ko ṣiṣẹ. | Batiri kekere; iṣẹ ṣiṣe ẹrọ naa ko dara. | Gba agbara si ẹrọ ni kikun. Ti iṣoro ba wa sibẹ, kan si atilẹyin. |
| Awọn kika ti ko pe. | Sensor obstruction; environmental interference; need for calibration. | Ensure air inlets are clear. Move away from strong air currents or dust sources. Consider professional calibration. |
| Iboju ti ṣofo tabi aotoju. | Software error; low battery. | Recharge the device. Perform a hard reset (refer to specific device manual for button combination, usually holding power for 10+ seconds). |
| Ko le sopọ si kọmputa. | Faulty USB cable; driver issue; device not in data transfer mode. | Try a different USB cable or port. Ensure the device is powered on and in data transfer mode if applicable. |
9. Awọn pato
9.1 Temtop PMD371 Particle Counter
- Particle Size Channels: 0.3µm, 0.5µm, 1.0µm, 2.5µm, 5.0µm, 10.0µm
- Measurement Range (PM2.5/PM10): 0-999 µg/m³
- Iwọn otutu: -10°C si 50°C (14°F si 122°F)
- Ibiti ọriniinitutu: 0-99% RH
- Batiri: Litiumu-dẹlẹ gbigba agbara
- Awọn iwọn: Isunmọ 170 x 110 x 48 mm (6.7 x 4.3 x 1.9 in)
- Ìwúwo: Isunmọ 0.8 kg (1.76 lbs)
- Ibi ipamọ data: Up to 5000 sets of data
9.2 Temtop Airing2000 Particulate Monitor
- Particulate Measurement: PM2.5, PM10, TSP
- Formaldehyde (HCHO) Range: 0-1.0 mg/m³
- Iwọn otutu: -10°C si 50°C (14°F si 122°F)
- Ibiti ọriniinitutu: 0-99% RH
- Batiri: Rechargeable Lithium-ion (Extended battery life)
- Ibi ipamọ data: Ample storage for continuous logging
- Orisi sensọ: Industrial-grade pumping sensor
10. Atilẹyin ọja ati Support
10.1 atilẹyin ọja Alaye
Temtop products typically come with a standard manufacturer's warranty covering defects in materials and workmanship. Please refer to the warranty card included with your product or visit the official Temtop website for specific warranty terms and conditions. Keep your purchase receipt as proof of purchase.
10.2 Onibara Support
For technical assistance, troubleshooting, or service inquiries, please contact Temtop customer support:
- Webojula: www.temtop.com
- Imeeli: Tọkasi apakan olubasọrọ lori osise webojula.
- Foonu: Tọkasi apakan olubasọrọ lori osise webojula.
When contacting support, please have your product model number (PMD371 & Airing2000) and purchase date ready.