1. Alaye Aabo pataki
Please read all instructions carefully before installation and operation. Retain this manual for future reference.
1.1 Gbogbogbo Abo
- Professional installation is required for this system to ensure proper function and safety.
- Ma ṣe gbiyanju lati tun tabi ṣe atunṣe ẹyọ naa funrararẹ. Kan si oṣiṣẹ iṣẹ ti o peye.
- Rii daju pe ipese agbara ibaamu awọn pato ti ẹyọkan (115V).
- Keep children and pets away from the outdoor unit during operation.
1.2 Itanna Abo
- Nigbagbogbo ge asopọ agbara ṣaaju ṣiṣe eyikeyi itọju tabi iṣẹ.
- Rii daju didasilẹ to dara lati ṣe idiwọ mọnamọna.
- Maṣe ṣiṣẹ ẹrọ pẹlu ọwọ tutu.
1.3 Refrigerant Safety
- Yi kuro nlo R32 refrigerant. Mu pẹlu abojuto ki o rii daju fentilesonu to dara lakoko fifi sori ẹrọ ati iṣẹ.
- R32 is a mildly flammable refrigerant. Do not use or store near open flames or heat sources.
- In case of a refrigerant leak, ventilate the area immediately.
2. Ọja Ipariview
The YITAHOME 12000 BTU Mini Split Air Conditioner Heat Pump System provides efficient cooling and heating for spaces up to 750 square feet. It features inverter technology for energy savings and smart controls for convenience.
2.1 Key Awọn ẹya ara ẹrọ
- Energy Efficient Cooling & Heating: High-power compressor and inverter technology for optimal performance and 25% energy savings. ETL and AHRI certified.
- Àwọn Ọ̀nà Ìṣiṣẹ́ Márùn-ún: Auto, Cool, Dry, Heat, and Fan modes for versatile climate control.
- Asopọmọra Smart: WiFi-enabled and compatible with Alexa for voice control and remote operation.
- Silent Performance: Operates quietly with noise levels below 41 decibels.
- All-Weather Response: Designed to perform in temperatures from 5°F to 118°F, providing consistent 4D air circulation up to 50 feet.
- Ipo Ilera: Awọn ẹya awọn ions odi, yiyọ eruku elekitirotiki, ati yiyọ PM2.5 fun imudara didara afẹfẹ.
- Awọn iṣẹ afikun: Automatic defrosting, self-diagnosis/cleaning, iFEEL mode, 24-hour timer, sleep mode, and energy-saving mode.
2.2 irinše To wa
- Inu ile Unit
- Ita gbangba Unit
- Multifunctional Isakoṣo latọna jijin
- Ohun elo fifi sori okeerẹ (laisi ile awọn falifu tiipa ati grille aabo ẹgbẹ)
- Itọsọna olumulo
- Washable Air Filter

3. Eto ati fifi sori
Proper installation is crucial for the optimal performance and longevity of your mini split system. It is highly recommended that installation be performed by a licensed professional.
3.1 Awọn irinṣẹ ati Awọn ohun elo ti a beere
- Iho ri
- Multimeter
- Pipe gige
- Hex wrenches
- Firiji (R32)
- Torque wrench
- adijositabulu wrench
- Iwọn teepu
- Iwọn titẹ
- Safety belt (for high installations)
- Flaring ọpa
- iṣagbesori biraketi
- Ipele
- Phillips dabaru
- Electrobe
- Igbale fifa
- Pliers
- Copper tube (if included pipes are not sufficient)
- Teepu ipari
- Putty
3.2 Abele Unit fifi sori
- Yan Ibi: Choose a hard, flat, and firm wall. Ensure adequate clearance: >15cm to ceiling, >20cm to obstacles on sides, and 230-260cm from floor.
- Fi sori ẹrọ Plate iṣagbesori: Place the mounting plate on the wall, use a level to ensure it is horizontal. Secure with at least 5 expansion screws. Do not use nails.
- Lilu Iho Odi: After determining the pipe's path, drill a wall hole inclined outward by 5-10 degrees, with a diameter of 60-80mm. Avoid wires, plumbing, and gas lines. Use an anti-dust bag.
- So okun agbara pọ: Pass the power cable from the back of the indoor unit and fix it to the terminal board according to the wiring diagram on the E-parts cover. Fix the cable with a clamp.
- Mura Pipa: Remove the knock-out panel according to piping direction. Use both hands to turn the refrigerant pipe in the desired direction to avoid deformation or rupture.
- So Pipin Firiji: Aim at the pipe center, tighten the taper nut with fingers, then tighten with two wrenches. Refer to the torque table for correct tightening force.
- Fi sori ẹrọ Hose Drain: Connect the drain hose with the water outlet pipe, ensuring it is fixed firmly with adhesive tape. The length should be more than 5cm.
- Wrap Piping: Fi ipari si paipu firiji, awọn okun onirin, ati paipu imugbẹ pẹlu teepu murasilẹ.
- Ẹka inu ile Oke: Put the refrigerant piping out of the wall hole. Place the indoor unit on the mounting plate. Push the lower part of the indoor unit until a 'click' sound is heard, ensuring it is firmly fixed.
- Seal Wall Hole: Install a pipe protecting ring and seal the wall hole with putty to prevent air and moisture ingress.
3.3 Ita gbangba Unit fifi sori
- Yan Ibi: The outdoor unit must be installed in a firm and flat place to prevent vibration and noise. Ensure adequate clearance: >20cm to top obstruction, >30cm to side obstructions, >10cm air in side, >200cm air out side.
- Fi Akọmọ Ẹka Ita gbangba sori ẹrọ: If installing at a higher place, wear a safety belt and helmet. Use a level to ensure the bracket is horizontal and vertical. Use at least 6 expansion bolts to fix brackets firmly on the wall.
- Place Outdoor Unit: Fi ẹyọ ita gbangba sori awọn biraketi. Lo awọn skru 4 lati ṣatunṣe awọn ẹsẹ ti ẹyọ ita gbangba.
- So Pipin Firiji: Remove the nut from the stop valves. Aim at the pipe center, tighten the taper nut with fingers, then tighten with two wrenches. Refer to the torque table for correct tightening force.
- Awọn Isopọ Itanna: Remove the electrical box cover. Fix cables to the terminal board according to the wiring diagram on the E-parts cover. Use clamps to fix cables. Must follow the wiring diagram inside the box cover. Put the electrical box cover back and secure it.
3.4 Vacuumizing and Refrigerant Charging
- Igbaradi: Ṣaaju ki o to fi omi ṣan, ṣayẹwo pe gbogbo awọn eso ti inu ile ati ita gbangba ti wa ni wiwọ.
- So Pump Vacuum pọ: So fáìlì ìdádúró, páìpù gbigba agbara, fáìlì onípele méjì, àti páìpù fífọ́ omi gẹ́gẹ́ bí a ṣe fihàn nínú àwòrán náà.
- Yọọ kuro: Turn on the handle Lo to vacuumize. Vacuumize for at least 15 minutes, ensuring the value on the pressure gauge is ≤0.1MPa. Keep pressure for 3-5 minutes after vacuumizing to ensure pressure springback is ≤0.05MPa.
- Ṣii Valves: Open the 1/4 liquid valve, and remove the charging hose. Open all the liquid valves and gas valves. Screw all the caps and tighten them up.
4. Awọn ilana Iṣiṣẹ
Your YITAHOME Mini Split system offers various modes and smart features for optimal comfort and convenience.
4.1 Latọna Iṣakoso Awọn iṣẹ
The multifunctional remote control allows you to adjust settings from 60°F to 90°F. It includes buttons for mode selection (Auto, Cool, Dry, Heat, Fan), fan speed, sleep mode, timer, and other special features.

4.2 Awọn ọna ṣiṣe
- Ipo Aifọwọyi: Automatically selects the appropriate operating mode (cooling, heating, or fan) based on the room temperature.
- Ipo Itura: Pese itutu agbaiye lati dinku iwọn otutu yara.
- Ipo gbigbẹ: Dehumidifies the air, reducing humidity levels.
- Ipo Ooru: Pese alapapo lati gbe iwọn otutu yara soke.
- Ipo Ipele: Circulates air lai itutu tabi alapapo.

4.3 Smart Awọn ẹya ara ẹrọ
- Ṣiṣẹ WiFi & Alexa ibaramu: Control your unit remotely via a smartphone app or voice commands through Alexa.
- Yiyo ni aifọwọyi: Prevents ice buildup on the outdoor unit during heating operation in cold weather.
- Ṣiṣayẹwo-ara ẹni/Isọtọ: The unit can detect and display error codes, and perform self-cleaning cycles for improved efficiency.
- Ipo iFEEL: Iṣakoso latọna jijin naa n mọ iwọn otutu ti o wa ni ayika rẹ ati ṣatunṣe iṣẹ ẹrọ naa fun itunu agbegbe.
- Aago 24-wakati: Ṣe eto ẹyọ naa lati tan tabi pa ni awọn akoko kan pato.
- Ipo orun: Ṣe atunṣe iwọn otutu ati iyara afẹfẹ fun oorun itunu lakoko fifipamọ agbara.
- Ipo fifipamọ agbara: Ṣe iṣiṣẹ dara julọ lati dinku agbara lilo.
- Ipo ILERA: Utilizes negative ions, electrostatic dust removal, and PM2.5 removal to enhance indoor air quality.

5. Itọju
Regular maintenance ensures the efficiency and longevity of your YITAHOME Mini Split system.
5.1 Air Filter Cleaning
The air filter is washable and easy to clean. It is recommended to clean the air filter every two weeks or more frequently depending on usage and air quality.
- Ṣii iwaju iwaju ti ẹyọ inu inu.
- Yọ awọn asẹ afẹfẹ kuro.
- Clean the filters with a vacuum cleaner or wash them with lukewarm water (below 40°C).
- Dry the filters completely in a shaded area before reinstalling.
- Tun fi awọn asẹ naa sori ẹrọ ki o si ti iwaju panẹli naa.
5.2 Gbogbogbo Cleaning
- Wipe the indoor and outdoor units with a soft, dry cloth. For stubborn dirt, use a damp asọ pẹlu kan ìwọnba detergent, ki o si mu ese gbẹ.
- Do not use harsh chemicals, abrasive cleaners, or solvents, as these can damage the unit's surface.
5.3 ti igba Itọju
- Before long periods of non-use (e.g., end of cooling season), run the unit in fan-only mode for a few hours to dry the internal components and prevent mold growth.
- Inspect the outdoor unit for any debris, leaves, or obstructions and clear them.
- Check the drain hose for blockages to ensure proper water drainage.
6. Laasigbotitusita
If you encounter issues with your YITAHOME Mini Split system, refer to the following common troubleshooting steps. If the problem persists, contact customer support.
- Ẹka ko tan: Ṣàyẹ̀wò ìpèsè agbára, ẹ̀rọ ìdènà, kí o sì rí i dájú pé àwọn bátìrì ìṣàkóso latọna jijin ṣiṣẹ́.
- Insufficient cooling/heating: Verify correct mode selection, set temperature, clean air filters, and ensure no obstructions around indoor/outdoor units.
- Awọn ariwo ti ko wọpọ: Minor noises during operation are normal. If loud or persistent, check for loose parts or contact service.
- Water leakage from indoor unit: Check if the drain hose is properly connected, sloped, and free from blockages.
- Awọn koodu aṣiṣe: Refer to the unit's display for specific error codes and consult the full user manual for detailed explanations and solutions.
- Iṣakoso latọna jijin ko ṣiṣẹ: Check batteries, ensure no obstructions between remote and indoor unit, and confirm the remote is set to the correct unit.
7. Awọn pato
| Sipesifikesonu | Iye |
|---|---|
| Brand | YITAHOME |
| Nọmba awoṣe | MAYIHoxw2t |
| Agbara Itutu | 12000 Awọn ẹya Gbona Ilu Gẹẹsi (BTU) |
| Agbara | 1 Toonu |
| Ipin Iṣiṣẹ Agbara Igba Igba (SEER2) | 20 |
| Voltage | 115 Volts |
| Wattage | 1040 watt |
| Ariwo Ipele | 41 Decibels |
| Ọja Mefa | 7.9"D x 31.2"W x 11.5"H (Indoor Unit) |
| Iwọn Nkan | 22 poun (Ẹka inu ile) |
| Ohun elo | Irin, Aluminiomu, Ṣiṣu |
| Pataki Awọn ẹya ara ẹrọ | Air Purification Filter, Auto Clean, Inverter Compressor, Sleep Mode, WiFi Enabled |

8. Atilẹyin ọja ati Support
8.1 atilẹyin ọja Alaye
The YITAHOME 12000 BTU Mini Split Air Conditioner Heat Pump System comes with a 5-odun atilẹyin ọja lori awọn ẹya ara ati a 7-odun atilẹyin ọja lori konpireso.

8.2 Onibara Support
For any questions, missing or damaged parts, or technical issues, please contact the manufacturer directly. YITAHOME is committed to providing 24/7 customer support.
- Replace missing or damaged parts.
- Troubleshoot technical issues.