1. Ifihan
Thank you for choosing the AQQA DC Aquarium Water Pump. This manual provides essential information for the safe and efficient operation of your pump. Designed for versatility, this pump is suitable for various aquatic environments, including freshwater and saltwater aquariums, ponds, fountains, and hydroponic systems. Its smart control features, quiet operation, and durable design ensure reliable performance.

Image 1: AQQA DC Aquarium Water Pump, showing the pump unit, external controller, and two interchangeable nozzles.
2. Alaye Aabo
Please read all safety instructions carefully before operating the pump. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Always disconnect the power supply before performing any maintenance, installation, or cleaning.
- Ensure the pump is fully submerged in water during operation to prevent dry burning and damage.
- Ma ṣe ṣiṣẹ fifa soke ti okun tabi plug ba bajẹ.
- This pump is designed for indoor use in aquatic environments only. Do not use it for purposes other than those specified.
- Jeki kuro ni arọwọto awọn ọmọde.
- The pump operates on a 12V DC low-voltage output, reducing shock risks. However, always handle electrical components with care.
3. Package Awọn akoonu
Daju pe gbogbo awọn nkan wa ninu apo rẹ:
- 1 x AQQA DC Aquarium Water Pump
- 1 x Ita Adarí
- 2 x Interchangeable Nozzles (6/8mm and 10/12mm)
- 1 x Power Cord (approximately 10.83 ft)
- 1 x Ilana itọnisọna
4. Ọja Ipariview
The AQQA DC Aquarium Water Pump is a compact and efficient submersible pump featuring an external controller for easy operation.
Pump Unit Features:
- Apẹrẹ Submersible: IP68 waterproof rating for continuous underwater operation.
- Isẹ idakẹjẹ: Pure copper motor ensures low noise levels (<30dB).
- Awọn ife mimu: Four strong suction cups on the base for secure placement.
- Apẹrẹ Ipele Omi Kekere: Capable of operating effectively at water levels as low as 1.5cm (0.59 inches), allowing for thorough drainage.
- Idaabobo sisun ti ko ni ipa lori gbigbẹ: Automatically shuts off if water levels are too low to prevent damage.

Image 2: The AQQA pump unit highlighting its anti-dry burning protection feature, which prevents damage when water levels are too low.
External Controller Features:
- Bọtini TAN/PA: Powers the pump on or off.
- Flow Adjustment Buttons (+/-): Adjusts water flow rate across 4 levels.
- Bọtini FEED: Activates feeding mode, pausing the pump for 10 minutes.
- Awọn imọlẹ Atọka: Display current flow rate/lift level and feeding mode status.

Image 3: Close-up of the external controller, showing the ON/OFF, flow adjustment (+/-), and FEED buttons, along with indicator lights for flow rate and feeding mode.
5. Eto
Follow these steps to install your AQQA DC Aquarium Water Pump:
- Yan Nozzle: Select the appropriate nozzle (6/8mm or 10/12mm) for your tubing system and securely attach it to the pump's outlet.
- Fifa ipo: Place the pump unit at the desired location within your aquarium, pond, or water feature. Ensure it is fully submerged. The four suction cups on the base will help secure it to a clean, smooth surface.
- Adarí Sopọ: Connect the pump's cable to the external controller.
- So agbara: Plug the power cord from the controller into a suitable electrical outlet (110V-240V).
- Jẹrisi Ipele Omi: Ensure the water level is sufficient to cover the pump completely. The pump can operate at low water levels (down to 1.5cm) but full submersion is recommended for optimal performance and longevity.

Image 4: The AQQA pump demonstrating its ability to operate effectively at low water levels, with all-around suction at the bottom to remove dirt.
6. Awọn ilana Iṣiṣẹ
The external controller provides easy access to all pump functions.
Titan/Apapa:
- Tẹ awọn TAN/PA button once to turn the pump on or off.
Iṣatunṣe Oṣuwọn Sisan:
- Lo awọn + button to increase the flow rate.
- Lo awọn - button to decrease the flow rate.
- There are 4 adjustable flow levels, indicated by the lights on the controller.
Ipo ifunni:
- To activate feeding mode, press and hold the OUNJE bọtini fun 5 aaya.
- The pump will pause for 10 minutes, allowing fish to feed without strong currents.
- After 10 minutes, the pump will automatically restart at its previous flow setting.
Video 1: Demonstrates the AQQA DC Water Pump's internal circulation, ultra-quiet operation, oxygen generation, wave-making capability, and the feeding mode function with the external controller.
7. Itọju
Regular cleaning and maintenance will ensure the longevity and optimal performance of your pump.
- Ge Agbara: Always unplug the pump from the power outlet before any maintenance.
- Pipa Sopọpo: The pump is designed for tool-free disassembly. Gently remove the filter cover and then the impeller assembly.
- Awọn ohun elo mimọ: Rinse all parts (impeller, filter cover, pump housing interior) under clean water. Use a soft brush to remove any accumulated debris, algae, or mineral deposits. Ensure the impeller spins freely.
- Ṣe atunto: Carefully reassemble the pump, ensuring all parts fit correctly.
- Awọn iṣayẹwo deede: Periodically check the pump and tubing for any blockages or wear.

Aworan 5: exploded view of the AQQA pump, illustrating how to easily disassemble the outlet nozzle, filter cover, and motor for cleaning without tools.
8. Laasigbotitusita
Tí o bá ní ìṣòro pẹ̀lú píńpù rẹ, wo àwọn ìṣòro àti ìdáhùn tó wọ́pọ̀ wọ̀nyí:
| Isoro | Owun to le Fa | Ojutu |
|---|---|---|
| Pump ko bẹrẹ | No power; Impeller jammed; Dry burning protection activated. | Check power connection; Disconnect and clean impeller; Ensure pump is fully submerged. |
| Iwọn sisan kekere | Blockage in pump or tubing; Flow rate set too low; Impeller worn. | Clean pump and tubing; Increase flow rate using controller; Inspect/replace impeller if necessary. |
| Ariwo ti o pọju | Debris in impeller; Pump not securely placed; Air trapped in pump. | Clean impeller; Re-secure pump with suction cups; Gently shake pump to release air. |
| Fifa duro lemọlemọ | Dry burning protection; Overheating; Loose connection. | Check water level; Ensure adequate ventilation (if applicable); Check all electrical connections. |
9. Awọn pato
| Ẹya ara ẹrọ | Sipesifikesonu |
|---|---|
| Nọmba awoṣe | AQ169 |
| Agbara | 25 Wattis |
| Oṣuwọn Sisan ti o pọju | 2200 liters fun wakati kan (480 GPH) |
| Iwọn Gbígbé Gbígbé | 7.2 Ẹsẹ |
| Voltage Input | 110-240V / 50-60Hz |
| Voltage Ijade | 12V DC |
| Ọja Mefa | 2.6"L x 2"W x 3"H |
| Iwọn Nkan | 12.8 iwon |
| Ohun elo | Acrylonitrile Butadiene Styrene (ABS) |
| IP Rating | IP68 |
| Nozzle Awọn iwọn | 6 / 8mm, 10 / 12mm |
| Agbara Okun Ipari | 10.83 ft |
10. Atilẹyin ọja ati Support
AQQA stands behind the quality of its products. For specific warranty details and terms, please refer to the warranty information provided at the time of purchase or visit the official AQQA webojula.
If you require technical assistance, have questions about your product, or need to report an issue, please contact AQQA customer support through the retailer where you purchased the product or via the contact information available on the official AQQA webojula.
Please have your model number (AQ169) and purchase date ready when contacting support.