ERICKHILL ETI-01

ERICKHILL ETI-01 Thermal Camera User Manual

Model: ETI-01

1. Ifihan

Thank you for choosing the ERICKHILL ETI-01 Thermal Camera. This device is designed for professional thermography, offering a 240x240 IR resolution and a wide temperature measurement range. It is suitable for various applications, including home inspections, HVAC diagnostics, electrical fault detection, and automotive analysis. This manual provides essential information for the safe and effective use of your thermal camera.

2. Ọja Ipariview ati irinše

The ERICKHILL ETI-01 thermal camera is a portable, handheld device featuring a clear display and intuitive controls. It comes with essential accessories to get you started.

2.1 Package Awọn akoonu

2.2 Device Awọn ẹya ara ẹrọ

ERICKHILL ETI-01 Thermal Camera with charging cable and carrying case

Figure 1: ERICKHILL ETI-01 Thermal Camera, showing the device, USB-C charging cable, and protective carrying case.

3. Eto

3.1 Ngba agbara si Ẹrọ

Before initial use, fully charge the thermal camera. The device is equipped with a 2500mAh rechargeable battery, providing extended operational time.

  1. Wa ibudo USB Iru-C lori ẹrọ naa.
  2. Connect the provided USB Type-C cable to the camera and a compatible USB power adapter (not included).
  3. The charging indicator on the screen will show the charging status. A full charge typically provides up to 8 hours of use.
ERICKHILL ETI-01 Thermal Camera showing battery life and Type-C charging port

Figure 2: The thermal camera displaying battery charge status and highlighting the Type-C charging port for its 2500mAh battery.

3.2 Titan / Pa a

4. Isẹ

4.1 Ìwọ̀n Ìwọ̀n Òtútù Pàtàkì

The ETI-01 provides precise temperature readings and visual thermal imaging.

  1. Point the camera lens towards the object or area you wish to measure.
  2. The screen will display a real-time thermal image, with temperature readings for the center, highest, and lowest temperature points within the view.
  3. For precise targeting, activate the laser pointer by pressing the trigger.
ERICKHILL ETI-01 Thermal Camera displaying real-time anomaly detection with hot, cold, and center spot indicators

Figure 3: The thermal camera screen showing real-time anomaly detection, indicating hot, cold, and center temperature spots.

4.2 Siṣàtúnṣe Eto

The device offers various settings to optimize your thermal imaging experience.

ERICKHILL ETI-01 Thermal Camera displaying 15 different thermal palettes

Figure 4: A visual representation of 15 different thermal palettes available on the ERICKHILL ETI-01 for versatile temperature visualization.

4.3 fifipamọ awọn aworan

The ETI-01 can store up to 30,000 radiometric images for later analysis.

  1. Once you have a desired thermal image on the screen, press the designated capture button (often the trigger or a specific button on the control panel).
  2. The image will be saved to the internal memory.
  3. Connect the camera to a computer via the USB-C cable to transfer and view ti o ti fipamọ images.
ERICKHILL ETI-01 Thermal Camera demonstrating precise measurement with accuracy and temperature range

Figure 5: The thermal camera in use, demonstrating precise temperature measurement with an accuracy of ±0.1°C and a range of -4°F to 1022°F (equivalent to -20°C to 550°C).

5. Itọju

5.1 Ninu ẹrọ naa

Regular cleaning ensures optimal performance and longevity of your thermal camera.

5.2 Ibi ipamọ

When not in use, store the camera in its provided storage bag in a cool, dry place, away from direct sunlight and extreme temperatures.

6. Laasigbotitusita

This section addresses common issues you might encounter with your ERICKHILL ETI-01 thermal camera.

IsoroOwun to le FaOjutu
Ẹrọ naa ko ṣiṣẹBatiri kekere; aiṣedeede ẹrọGba agbara si ẹrọ ni kikun. Ti ọrọ naa ba wa, kan si atilẹyin alabara.
Awọn kika iwọn otutu ti ko peIncorrect emissivity setting; lens obstruction; measurement distance too farAdjust emissivity for the target material. Clean the lens. Ensure measurement is within optimal range.
Screen frozen or unresponsiveAṣiṣe sọfitiwiaPerform a soft reset by holding the power button for 10-15 seconds. If unresponsive, allow the battery to drain completely and then recharge.
Cannot transfer images to computerFaulty USB cable; driver issue; incorrect connection modeTry a different USB-C cable. Ensure the camera is in data transfer mode (if applicable). Check computer drivers.

7. Awọn pato

Key technical specifications for the ERICKHILL ETI-01 Thermal Camera.

Ẹya ara ẹrọSipesifikesonu
Orukọ awoṣeETI-01
Iwọn IR240x240 awọn piksẹli
Iwọn Iwọn Iwọn otutu-20°C si +550°C (-4°F si 1022°F)
Yiye+/-2°C or +/-2% of reading
Oṣuwọn sọtun25Hz
Batiri Iru1 Lithium-ion (pẹlu)
Agbara Batiri2500mAh
Igbesi aye batiriTiti di wakati 8
Ibi ipamọ4G eMMC (for 30,000 radiometric images)
AsopọmọraUSB Iru-C
Awọn iwọn Ọja (L x W x H)22.9 x 9.7 x 7.3 cm
Iwọn540 giramu
Ohun eloṢiṣu

8. Atilẹyin ọja ati Support

ERICKHILL is committed to providing high-quality products and customer service.

8.1 Olupese ká atilẹyin ọja

Ọja yi wa pẹlu kan 3-odun olupese ká atilẹyin ọja. Jọwọ ṣe idaduro ẹri rira rẹ fun awọn iṣeduro atilẹyin ọja.

8.2 Onibara Support

For technical assistance, calibration services, or any inquiries regarding your ERICKHILL ETI-01 Thermal Camera, please contact our customer support team. We offer 24/7 support and free firmware updates.

Awọn iwe aṣẹ ti o jọmọ - ETI-01

Ṣaajuview ERICKHILL ROOK 400/600 SP IR Itanwo Itọsọna olumulo
Itọsọna olumulo fun ERICKHILL ROOK 400 SP ati ROOK 600 SP infurarẹẹdi thermometers. Pese awọn itọnisọna lori iṣẹ, awọn ẹya, ailewu, ati awọn alaye imọ-ẹrọ.
Ṣaajuview ERICKHILL ER02 EMF Mita Itọsọna olumulo
Ṣawari awọn agbara ti ERICKHILL ER02 EMF Mita pẹlu itọnisọna olumulo okeerẹ yii. Kọ ẹkọ nipa iṣẹ ṣiṣe 3-in-1 rẹ fun wiwọn ina, oofa, ati awọn aaye igbohunsafẹfẹ redio, pẹlu iṣẹ ṣiṣe, awọn pato, ati awọn itọnisọna ailewu.
Ṣaajuview Erickhill RT-100S EMF Mita olumulo Afowoyi
Itọsọna olumulo fun Erickhill RT-100S EMF Mita, ṣe alaye awọn ẹya rẹ, iṣẹ ṣiṣe, awọn alaye imọ-ẹrọ, ati awọn ohun elo fun wiwọn ina, oofa, ati awọn aaye RF.
Ṣaajuview SKYRC ITV500 Mini HeatVision Thermal Camera - Instruction Manual
Instruction manual for the SKYRC ITV500 Mini HeatVision, a portable thermal camera designed for RC model enthusiasts. Covers features, operation, specifications, warnings, and measurement tips.
Ṣaajuview ETI Pen-Shaped Thermometer 810-260 Operating Instructions
Comprehensive operating instructions for the ETI 810-260 Pen-Shaped Thermometer, covering instrument operation, temperature scale selection, hold function, battery replacement, and guarantee details. Includes multilingual summaries.