1. Ifihan
Thank you for choosing the INKBIRDPLUS PM2.5 Indoor Air Quality Monitor. This portable device is designed to provide accurate and real-time measurements of PM2.5, PM10, temperature, and humidity in your environment. It features a clear VA color screen, sound and light dual alerts, and a power-saving design, making it an essential tool for monitoring air quality in homes, offices, and schools.
2. Ọja Ipariview
2.1 Package Awọn akoonu
- 1 x INKBIRDPLUS PM2.5 Indoor Air Quality Monitor
- 1 x Okun Ngba agbara USB-C
- 1 x Awọ okun
2.2 Device irinše
Familiarize yourself with the different parts of your air quality monitor:

Nọmba 1: Iwaju ati ẹgbẹ view of the INKBIRDPLUS PM2.5 Indoor Air Quality Monitor with labels for its various components such as the display, control buttons, sensors, and magnetic back.
- Iboju ifihan: Shows PM2.5/PM10 values, temperature, humidity, and battery status.
- Awọn bọtini:
- Top Button (▲): Mute/Unmute sound.
- Middle Button (●): Power ON/OFF, Confirm setting.
- Bottom Button (▼): Switch temperature unit (°C/°F).
- PM2.5/PM10 Indicator Light: A 3-color breathing light (Green, Orange, Red) indicating air quality levels.
- Iho Lanyard: For attaching a wrist strap or hanging.
- Itaniji ohun: Emits an audible alert when PM2.5/PM10 levels exceed the set threshold.
- Iwọn otutu ati sensọ ọriniinitutu: Located on the side for accurate environmental readings.
- Afẹfẹ afẹfẹ: Allows air circulation for sensor readings.
- Oofa: On the back for easy attachment to magnetic surfaces.
3. Eto
3.1 Gbigba agbara akọkọ
Before first use, fully charge the device using the provided USB-C cable. Connect the cable to the charging port on the monitor and a standard USB power adapter (not included). The battery indicator on the screen will show charging status.
3.2 Titan / Pa a
To power on or off the detector, long press the middle (●) button.
Fidio 1: Demonstrates how to power on and off the INKBIRDPLUS PM2.5 Indoor Air Quality Monitor by long-pressing the middle button. The video also shows how to mute/unmute the sound and switch temperature units.
4. Awọn ilana Iṣiṣẹ
4.1 Real-akoko Abojuto
Once powered on, the monitor will immediately begin displaying real-time readings for PM2.5, PM10, temperature, and humidity. The VA color screen provides clear visibility of all data.

Nọmba 2: The monitor's display showing current air quality and environmental data.
4.2 Air Quality Indication (PM2.5/PM10)
The monitor features a 3-color breathing light around the middle button to provide a quick visual indication of PM2.5 air quality:
- Imọlẹ alawọ ewe: Indicates good air quality (0 to 34 µg/m³).
- Imọlẹ Orange: Indicates a warning, moderate air quality (35 to 110 µg/m³).
- Imọlẹ pupa: Indicates danger, poor air quality (above 110 µg/m³).

Nọmba 3: Visual guide to the PM2.5/PM10 indicator light colors and their corresponding air quality levels.
4.3 Yipada iwọn otutu
To switch between Celsius (°C) and Fahrenheit (°F) for temperature display, long press the bottom (▼) button.
4.4 Mute/Unmute Sound
To turn the sound alarm on or off, long press the top (▲) button.
4.5 Setting PM2.5 Alarm Value
The PM2.5/PM10 alarm threshold can be customized. When the concentration exceeds this threshold, the detector will sound an alarm and the indicator light will flash red.
- Double press the middle (●) button to enter the alarm setting mode.
- Use the top (▲) or bottom (▼) buttons to adjust the desired alarm number.
- Press the middle (●) button to confirm the number and move to the next digit or setting.
- Once the setting is complete, press the middle (●) button again to save and return to the main display.

Nọmba 4: Illustration of the dual alert system for high PM2.5/PM10 levels.
4.6 Power-Saving Features
- The screen will automatically turn off when no data changes within 5 minutes to conserve power.
- The device will automatically power off after 25 minutes of inactivity to further save battery life.

Nọmba 5: The monitor's power-saving capabilities, including automatic shutdown.
5. Itọju
- Keep the device clean by wiping it with a soft, dry cloth. Do not use abrasive cleaners or solvents.
- Ensure the air vents are clear of dust and debris to maintain accurate readings.
- Tọju atẹle naa ni itura, aye gbigbẹ nigbati o ko ba lo.
- Yago fun ṣiṣafihan ẹrọ naa si awọn iwọn otutu to gaju, oorun taara, tabi ọriniinitutu giga.
6. Laasigbotitusita
| Isoro | Owun to le Fa | Ojutu |
|---|---|---|
| Ẹrọ naa ko ṣiṣẹ. | Batiri kekere. | Gba agbara si ẹrọ ni kikun nipa lilo okun USB-C. |
| Awọn kika ti ko pe. | Air vents blocked; device exposed to extreme conditions; sensor interference. | Ensure air vents are clear. Move device away from strong air currents, heat sources, or high humidity. Restart the device. |
| Itaniji n dun nigbagbogbo. | High PM2.5/PM10 levels; alarm threshold set too low. | Check air quality in the area. Adjust the PM2.5 alarm threshold if necessary (refer to section 4.5). |
| Iboju naa ma n pa ni kiakia ju. | Automatic screen-off feature is active. | This is a normal power-saving feature. The device is still monitoring. |
7. Awọn pato
| Paramita | Iye |
|---|---|
| PM2.5 Range erin | 0 to 1000 µg/m³ |
| PM10 Range erin | 0 to 1000 µg/m³ |
| Iwọn Wiwa Iwọn otutu | -10 ° C si 50 ° C / 14 ° F si 122 ° F |
| Ọriniinitutu Wiwa Ibiti | 0% si 95% RH |
| Batiri Iru | 1 batiri litiumu ion (pẹlu) |
| Agbara Batiri | 1000mAh |
| Awọn iwọn | 4.29 x 2.17 x 1.61 inches |
| Iwọn | 4.16 iwon |
| Olupese | Inkbird |
| Ilu isenbale | China |
8. Atilẹyin ọja ati Support
For warranty information and technical support, please refer to the official INKBIRDPLUS webojula tabi kan si wọn onibara iṣẹ taara. Tọju iwe-ẹri rira rẹ fun awọn ẹtọ atilẹyin ọja.
Olupese: Inkbird
Brand: INKBIRDPLUS