1. Ifihan
This manual provides detailed instructions for the Waveshare Industrial Modbus RTU 4-Channel Relay Module. This module is designed for industrial control applications, offering robust RS485 communication, high current switching capabilities, and comprehensive protection features. It is suitable for various scenarios requiring intelligent and automated control.

Aworan 1.1: Pariview of the Waveshare Industrial Modbus RTU 4-Channel Relay Module.
2. Key Awọn ẹya ara ẹrọ
- Configurable RS485 Communication: Device address is configurable (1~255), allowing multiple devices to be cascaded on the RS485 bus for flexible networking.
- Relay Control with Flash-on/Flash-off: Supports flash-on/flash-off function, enabling relay activation for a specific period before automatically turning off via command arguments.
- Jakejado Voltage Range & Isolation: Lori ọkọ voltage regulator supports 7V~36V wide voltage supply, with unibody power supply isolation for stable, isolated voltage without requiring an extra power supply for the isolated terminal.
- Awọn ẹya Idaabobo To ti ni ilọsiwaju: Includes onboard resettable fuse, TVS (Transient Voltage Suppressor), optocoupler isolation, and relay driver chip with flyback diode protection for surge suppression, anti-electrostatic, and high-voltage interference prevention.
- Reliable, Easy Installation: High-quality relay with a contact rating of ≤30A 250V AC or ≤30A 28V DC, housed in a rail-mounted ABS plastic enclosure with 3 LEDs to indicate MCU and signal transceiving status.
- Rich Wiki Resources: Additional resources are available on the official Waveshare Wiki.
3. Package Awọn akoonu
Package pẹlu awọn nkan wọnyi:
- Modbus RTU Relay 4CH x1
Note: The power supply for this product is not included. A 12V power supply is recommended. A USB to RS232/485/TTL or USB to RS485 converter may be useful for testing and communication setup.

Image 3.1: Contents of the product package, showing the Modbus RTU Relay 4CH module.
4. Awọn pato
| Paramita | Iye |
|---|---|
| Ibi ti ina elekitiriki ti nwa | 7-36V |
| Ibaraẹnisọrọ Interface | RS485 |
| Ṣàyẹ̀wò | 4800, 9600, 19200, 38400, 57600, 115200, 128000, 256000 |
| Default Communication Format | 9600, N, 8, 1 |
| Relay awọn ikanni | 4 |
| Fọọmu olubasọrọ | 1NO 1NC (Normally Open, Normally Closed) |
| Olubasọrọ Rating | ≤30A 250V AC or ≤30A 28V DC |
| Ilana ibaraẹnisọrọ | Standard Modbus RTU protocol |
| RS485 adirẹsi | 1-255 (Configurable) |
| LED Ifi | STA: MCU indicator (keeps flashing when MCU is working normally) TXD: TX indicator (lights up when sending data) RXD: RX indicator (lights up when receiving data) |
| Iṣagbesori Iru | DIN Rail Oke |
| Ohun elo olubasọrọ | Fadaka |
| Asopọmọra Iru | dabaru TTY |

Image 4.1: Visual representation of the module's features and technical specifications.
5. Eto ati fifi sori
5.1 Power Ipese Asopọ
Connect a 7V to 36V DC power supply to the designated power input terminals on the module. Ensure correct polarity (+ and -). The module features an onboard voltage regulator and power supply isolation for stable operation.
5.2 RS485 Interface Connection
Connect the RS485 A+ and B- terminals of the module to your RS485 master device (e.g., a computer via a USB to RS485 converter). For multi-device setups, ensure proper cascading and consider using RS485 repeaters for long communication distances.

Image 5.1: Diagram illustrating RS485 communication setup with multiple modules and examples of AC and DC relay connections.
5.3 Relay Output Asopọ
Each of the 4 relay channels provides Normally Open (NO) and Normally Closed (NC) contacts, along with a Common (COM) terminal. Connect your target device (e.g., light, motor, valve) to the appropriate relay contacts based on your control requirements. The high current screw terminals are designed for secure wiring of devices up to 30A.

Aworan 5.2: alaye view of the high current screw terminals and a hardware analysis showing internal components like optocoupler isolation and TVS protection.
5.4 Rail-Mount Installation
The module is housed in a rail-mounted ABS plastic enclosure, facilitating easy installation and removal on standard DIN rails in industrial control cabinets.

Image 5.3: Illustration of the module's interfaces, LED indicators, and its rail-mount enclosure design.
6. Awọn ilana Iṣiṣẹ
6.1 Modbus RTU Communication
The module communicates using the standard Modbus RTU protocol over the RS485 interface. You can send Modbus commands from a master device to control the relays and read their status. The device address is configurable from 1 to 255.
For detailed Modbus command structures and register maps, refer to the official Waveshare Wiki resources.
6.2 yii Iṣakoso
Relays can be controlled individually or in groups using Modbus commands. The module supports standard ON/OFF commands. Additionally, a flash-on/flash-off function allows a relay to be activated for a specified duration before automatically deactivating.
6.3 LED Atọka
- STA (Status) LED: Flashes continuously when the Microcontroller Unit (MCU) is operating normally.
- TXD (Transmit) LED: Lights up when the module is sending data over RS485.
- RXD (Receive) LED: Lights up when the module is receiving data over RS485.
These indicators provide visual feedback on the module's operational status and communication activity.
6.4 Eksample of Modbus Control
The following video demonstrates the Modbus RTU Relay series, including connection and basic operation using Modbus commands. This can serve as a practical guide for controlling the module.
Fidio 6.1: Ipariview of the Waveshare Modbus RTU Relay series, demonstrating various models and their operational principles. This video highlights the features and application scenarios of the relay modules.
7. Awọn ohun elo
The Waveshare Modbus RTU Relay Module is versatile and can be applied in various fields:
- Industrial Control: Ideal for valve control, pump station control, and unattended industrial control systems.
- Ile Smart: Suitable for controlling appliances like air conditioners, access control systems, purifiers, and water heaters.
- Smart Agriculture: Can be used for controlling door curtain motors, air blowers, and other agricultural equipment.
- Breeding & Farming: Useful for controlling ventilators, lighting, water supply systems, and feeding systems in breeding and farming environments.

Aworan 7.1: Examples of diverse applications for the Modbus RTU Relay Module.
8. Itọju
The Waveshare Modbus RTU Relay Module is designed for reliable operation with minimal maintenance. To ensure longevity and optimal performance:
- Jẹ́ kí module náà mọ́ tónítóní kí ó sì wà láìsí eruku àti ìdọ̀tí.
- Rí i dájú pé afẹ́fẹ́ ń yọ́ dáadáa tí a bá fi sínú àyè tí a pamọ́.
- Regularly check all wiring connections for tightness and integrity.
- Avoid exposing the module to extreme temperatures or humidity beyond its specified operating conditions.
9. Laasigbotitusita
If you encounter issues with your Modbus RTU Relay Module, consider the following troubleshooting steps:
- Ko si Agbara/Awọn LED Pipa: Daju awọn ipese agbara voltage (7-36V) and ensure correct polarity. Check power connections.
- Ikuna ibaraẹnisọrọ:
- Check RS485 wiring (A+ to A+, B- to B-).
- Confirm baudrate, data bits, parity, and stop bits settings match between the master device and the module (default: 9600, N, 8, 1).
- Ensure the device address is correctly configured and unique on the bus.
- Check for proper termination resistors on the RS485 bus if applicable (not explicitly mentioned for this module, but good practice for RS485).
- Observe TXD/RXD LEDs for data transmission activity.
- Relay Ko Ṣiṣẹ:
- Verify the Modbus command sent is correct for the desired relay and action.
- Check the load connected to the relay for proper wiring and functionality.
- Rii daju pe sisan agbara ati vol wa ni agbaratage do not exceed the relay's contact rating (≤30A 250V AC or ≤30A 28V DC).
- Module gbigbona: Ensure adequate ventilation around the module. Reduce load if consistently operating at maximum capacity.
For further assistance, consult the Waveshare Wiki or contact technical support.
10. Atilẹyin ọja ati Support
For detailed warranty information, please refer to the official Waveshare website or the documentation provided with your purchase. Waveshare provides comprehensive resources and support for its products.
- Awọn orisun Ayelujara: Visit the official Waveshare Wiki for detailed documentation, examples, and software resources. The Wiki is a primary source for technical information.
- Oluranlowo lati tun nkan se: For specific technical inquiries or issues not covered in this manual or the Wiki, please contact Waveshare customer support through their official channels.