1. Ifihan
The ANENG PN130 is a versatile, U-shaped clamp multimeter designed for efficient and accurate electrical measurements. Featuring a color LCD and a rechargeable lithium battery, this tool is ideal for diagnosing electrical issues in various settings, from automotive systems to household circuits. It offers a wide range of measurement capabilities including AC/DC current, voltage, resistance, capacitance, continuity, diode testing, and frequency. The non-contact voltage (NCV) detection function enhances safety during operation.
2. Alaye Aabo
Always observe basic safety precautions when using this device to avoid potential electric shock or personal injury.
- Ka ati loye gbogbo awọn ilana ṣaaju lilo.
- Má ṣe kọjá iye ìtẹ̀síwájú tó pọ̀ jùlọ tí a sọ fún iṣẹ́ ìwọ̀n kọ̀ọ̀kan.
- Lo iṣọra nigbati o ba n ṣiṣẹ pẹlu voltages loke 30V AC RMS, 42V tente oke, tabi 60V DC. Awọn wọnyi ni voltages duro a mọnamọna ewu.
- Always disconnect power to the circuit under test before making resistance, capacitance, or diode measurements.
- Rí i dájú pé àwọn ìtọ́wò ìdánwò náà so pọ̀ dáadáa àti pé wọ́n wà ní ipò tó dára kí o tó lò ó.
- Má ṣe lo mita náà bí ó bá dàbí pé ó ti bàjẹ́ tàbí tí àpótí náà bá ṣí sílẹ̀.
- Use the Non-Contact Voltage (NCV) function to detect live wires without direct contact, enhancing safety.
- Wọ àwọn ohun èlò ààbò ara ẹni tó yẹ (PPE), bíi àwọn gíláàsì ààbò àti àwọn ibọ̀wọ́ tí a fi ààbò pamọ́, nígbà tí o bá ń ṣiṣẹ́ pẹ̀lú àwọn ẹ̀rọ iná mànàmáná.
3. Package Awọn akoonu
The ANENG PN130 Clamp Multimeter package includes the following items:
- 1 x ANENG PN130 Multimeter
- 1 x Combination Test Lead Set (includes 4 connection jacks, 2 PVC cables, 2 copper needles, 2 U-shaped inserts, 2 test probes, 2 alligator clips, 2 piercing needles)
- 1 x Standard Multimeter Test Lead
- 1 x Okun Ngba agbara USB-C
- 1 x Ilana itọnisọna
- 1 x Apo Ibi ipamọ

Image: Contents of the ANENG PN130 package, including the multimeter, various test leads, charging cable, manual, and storage bag.
4. Awọn ẹya Ọja
- Efficient Measurement and Troubleshooting: Equipped with True-RMS functionality, capable of measuring AC/DC current, voltage, resistance, capacitance, continuity, diode, frequency (Hz), and identifying phase/neutral lines. This digital clamp meter is an optimal tool for diagnosing electrical issues in vehicles and internal electrical systems, significantly improving work efficiency.
- U-sókè Clamp Apẹrẹ: The ANENG PN130 features a U-shaped design, allowing for easy clamping around wires without the need to cut them. This enables quick measurements in confined spaces. It also includes a data hold function for convenient recording and subsequent analysis of measured values.
- Non-Olubasọrọ Voltage (NCV) Function: To utilize the NCV function, long-press the Yan button to enter NCV mode. Hold the top of the clamp meter near the cable or circuit you wish to test. The device will emit an audible alert upon detecting an electromagnetic field. This feature allows for current measurement without direct contact with live conductors, reducing the risk of electric shock and enhancing user safety.
- Gbigba agbara ati Gbe: The PN130 multimeter boasts a compact and portable design, powered by a USB-C rechargeable lithium battery. It can be charged even while performing measurements. This makes it suitable for a wide range of tasks, from simple DIY continuity checks to complex outdoor or garage work, providing stable measurement values without concerns about power supply.
- Color LCD with Backlight: The device features a clear color LCD display with backlight, ensuring readability in various lighting conditions.
- Ina Filaṣi ti a ṣe sinu: A built-in flashlight assists in illuminating dark work areas.

Image: The ANENG PN130 Multimeter highlighting its various measurement capabilities and display features.
5. Eto
5.1. Fifi sori batiri ati gbigba agbara
The ANENG PN130 comes with a built-in rechargeable lithium battery.
- Before first use, ensure the battery is fully charged using the provided USB-C charging cable.
- Connect the USB-C cable to the multimeter's charging port and the other end to a standard USB power adapter (not included).
- The battery status will be indicated on the color LCD.

Image: The ANENG PN130 Multimeter connected to a USB-C charging cable, demonstrating its rechargeable feature.
5.2. Nsopọ Awọn itọsọna Igbeyewo
For measurements requiring direct contact, connect the test leads to the appropriate input jacks on the multimeter.
- Insert the black test lead into the "COM" (common) jack.
- Insert the red test lead into the "VΩmA" jack for voltage, resistance, capacitance, igbohunsafẹfẹ, ati awọn wiwọn diode.
- Ensure a secure connection for accurate readings.
6. Awọn ilana Iṣiṣẹ
6.1. Agbara Tan / Paa
Press the power button to turn the multimeter ON or OFF. The device may have an auto-power-off feature to conserve battery.
6.2. Aṣayan iṣẹ
Rotate the central dial to select the desired measurement function (e.g., AC current, DC voltage, resistance). Use the Yan button to toggle between different sub-functions within a mode (e.g., AC or DC voltagati).
6.3. Ìwọ̀n Ìṣàn AC/DC (Cl)amp Iṣẹ́)
Awọn U-sókè clamp allows for non-invasive current measurement.
- Turn the dial to the AC or DC current measurement mode (indicated by A~ or A=).
- Tẹ okunfa lati ṣii clamp ẹrẹkẹ.
- Fi adarí kan ṣoṣo (kì í ṣe àpapọ̀ wáyà) sínú cl náàamp ẹrẹkẹ.
- Tu ohun ti nfa silẹ lati pa awọn ẹrẹkẹ ni aabo ni ayika adaorin.
- Ka iye lọwọlọwọ lori ifihan naa.

Image: The ANENG PN130 Multimeter being used to measure DC current in a vehicle's engine compartment.

Image: The ANENG PN130 Multimeter measuring AC current by clamping around a single wire in an electrical distribution panel.
6.4. AC / DC Voltage Idiwon
Lati wiwọn voltage:
- Connect the test leads to the appropriate jacks (black to COM, red to VΩmA).
- Yii ipe kiakia si voltage measurement mode (V~ for AC, V= for DC). Use the Yan bọtini ti o ba nilo.
- Fi ọwọ kan awọn ohun elo idanwo si awọn aaye nibiti o fẹ lati wọn iwọn diduntage.
- Ka voltage iye lori ifihan.

Image: The ANENG PN130 Multimeter with test leads connected, measuring AC/DC voltage from a power strip.
6.5. Resistance, Capacitance, Diode, and Continuity Measurement
For these measurements, ensure the circuit is de-energized before connecting the test leads.
- Connect the test leads (black to COM, red to VΩmA).
- Turn the dial to the appropriate mode (Ω for resistance, ∔ for capacitance, ⇋ for diode, or )) for continuity). Use the Yan button to cycle through these functions if they share a dial position.
- Touch the test probes to the component or circuit points.
- Read the value on the display. For continuity, an audible beep indicates a continuous circuit.
6.6. Frequency (Hz) Measurement
Lati wiwọn igbohunsafẹfẹ:
- Connect the test leads (black to COM, red to VΩmA).
- Turn the dial to the frequency mode (Hz).
- Touch the test probes to the circuit points where you want to measure frequency.
- Ka iye igbohunsafẹfẹ lori ifihan.
6.7. Non-olubasọrọ Voltage (NCV) erin
The NCV function allows for safe detection of live voltage lai taara olubasọrọ.
- Gun-tẹ awọn Yan button to activate NCV mode. The display will show "NCV".
- Move the top part of the clamp meter close to the suspected live wire or electrical outlet.
- Ti AC voltage is detected, the meter will emit an audible beep and the NCV indicator will light up, with intensity varying based on signal strength.

Image: The ANENG PN130 Multimeter's built-in flashlight providing illumination in a low-light environment.
6.8. Data Hold and Backlight
- Tẹ awọn DIMU bọ́tìnì láti dì kíkà tó wà lórí ìbòjú náà. Tẹ̀ lẹ́ẹ̀kan síi láti tú u sílẹ̀.
- Press the backlight button (often indicated by a light bulb icon) to turn the display backlight ON or OFF for improved visibility in dim conditions.

Image: The ANENG PN130 Multimeter's color LCD display showing a reading with the backlight activated and the data hold function engaged.
6.9. Itumọ ti Flashlight
The multimeter includes a built-in flashlight to illuminate dark work areas. This is typically activated by a dedicated button or a long press of the backlight button.

Image: The ANENG PN130 Multimeter's built-in flashlight providing illumination in a low-light environment.
7. Itọju
- Ninu: Fi aṣọ gbígbẹ tí ó rọ, nu mita náà. Má ṣe lo àwọn ohun ìpara tàbí àwọn ohun èlò ìfọ́mọ́ra.
- Ibi ipamọ: When not in use for extended periods, store the multimeter in its protective storage bag in a cool, dry place.
- Itọju Batiri: Recharge the lithium battery regularly to maintain its lifespan, even if the device is not frequently used.
- Awọn itọsọna Idanwo: Inspect test leads for any damage (cuts, cracks) before each use. Replace damaged leads immediately.
8. Laasigbotitusita
If the multimeter is not functioning as expected, consider the following:
- Ko si Ifihan/Batiri Kekere: Ensure the battery is charged. Connect the USB-C charging cable and allow it to charge for some time.
- Awọn kika ti ko tọ:
- Check if the correct function mode is selected for the measurement.
- Verify that test leads are securely connected to the correct input jacks.
- Ensure the circuit under test is de-energized for resistance, capacitance, and diode measurements.
- For current measurements with the clamp, ensure only a single conductor is enclosed.
- A ko ri NCV: Ensure NCV mode is activated (long-press SELECT). The sensitivity may vary with distance and electromagnetic field strength.
- Ko si Beep Tesiwaju: Check if the continuity mode is selected. Ensure the circuit is complete and has very low resistance.
If issues persist, refer to the detailed instruction manual provided in the package or contact ANENG customer support.
9. Awọn pato
| Ẹya ara ẹrọ | Sipesifikesonu |
|---|---|
| Brand | ANENG |
| Awoṣe | PN130 |
| Orisi wiwọn | True-RMS Clamp Multimeter |
| Ifihan | Color LCD, 4000 Counts, Backlit |
| Iwọn Iwọn lọwọlọwọ | AC/DC Current (U-shaped clamp) |
| Voltage Idiwon | AC/DC Voltage |
| Idiwọn Resistance | Bẹẹni |
| Iwọn Iwọn agbara | Bẹẹni |
| Wiwọn Igbohunsafẹfẹ | Yes (Hz) |
| Tesiwaju Ṣayẹwo | Bẹẹni |
| Idanwo Diode | Bẹẹni |
| Non-Olubasọrọ Voltage (NCV) | Bẹẹni |
| Orisun agbara | Rechargeable Lithium Metal Battery (USB-C) |
| Awọn iwọn Ọja (LxWxH) | 50 x 20 x 50 mm |
| Iwọn Nkan | 0.6 g |
10. Atilẹyin ọja ati Support
For warranty information, technical support, or service inquiries regarding your ANENG PN130 Clamp Multimeter, please refer to the contact details provided in the included instruction manual or visit the official ANENG webojula.