1. Ifihan
This manual provides essential information for the proper installation, operation, and maintenance of your DAYTECH AJ-762 Smoke Detector. This device is designed to provide early warning of smoke presence, contributing to the safety of your home. Please read these instructions carefully before installation and retain them for future reference.
2. Alaye Aabo
- The DAYTECH AJ-762 Smoke Detector is certified by TÜV Rheinland and complies with EN 14604:2005 and EN14604 2005/AC:2008 standards.
- This device is equipped with a sealed 10-year lithium battery. The battery is not replaceable.
- Do not paint the smoke detector. Painting may interfere with the sensor's ability to detect smoke.
- Ensure the detector is installed in an area where temperatures remain between 0°C and 40°C. Avoid extreme temperatures.
- Regularly test the smoke detector as described in the 'Operation' section.
- In case of an alarm, evacuate the premises immediately and contact emergency services.
3. Awọn ẹya Ọja
- Igbesi aye batiri Ọdun 10: Integrated sealed lithium battery provides power for 10 years, eliminating the need for frequent battery changes.
- Sensọ Fọtoelectric: Utilizes photoelectric technology for sensitive smoke detection, reducing false alarms from cooking fumes.
- Itaniji ti npariwo: Emits an 85 dB alarm signal to ensure early warning, even during sleep.
- Test/Mute Button: Allows for easy testing of the alarm function and silencing of false alarms.
- Idanwo Ara-ẹni Aifọwọyi: The device performs an automatic self-test every 50 seconds, indicated by a subtle LED flash.
- Ikilọ Batiri Kekere: A 'DI' sound and a red LED flash every 50 seconds indicate a low battery, signaling the need for detector replacement.
- Idaabobo kokoro: Features a 0.6mm steel mesh to prevent insects from entering and causing false alarms or damage.
- Ikole ti o tọ: Made from flame-retardant ABS material for enhanced safety and longevity.

Aworan: Pariview of DAYTECH Smoke Detector features, including 10-year power, stable temperature operation, energy-saving design, synchronized sensor/battery lifespan, and sealed unit with end-of-life warning.

Image: DAYTECH Smoke Detector on a wall in a living room with a family, highlighting TÜV Rheinland certification, 10-year battery, and 85dB alarm volume.

Image: Diagram illustrating the 0.6mm steel mesh insect protection layer within the DAYTECH Smoke Detector, designed to extend its lifespan.

Image: Comparison showing the DAYTECH Smoke Detector's flame-retardant ABS material resisting fire, contrasted with a non-resistant material melting, emphasizing its robust housing and auto-test function.
4. Package Awọn akoonu
Ni ṣiṣi package, jọwọ rii daju pe gbogbo awọn paati wa:
- DAYTECH AJ-762 Smoke Detector Unit(s)
- Mounting Plate(s)
- Iṣagbesori skru ati Wall Plugs
- 3M Adhesive Mounting Pad(s) (optional magnetic mounting)
- Itọsọna olumulo

Image: Contents of the DAYTECH Smoke Detector package, including two smoke detectors, magnetic mounting plates with 3M adhesive, screws, and the user manual.
5. fifi sori
The DAYTECH AJ-762 Smoke Detector offers two installation methods: screw mounting or magnetic adhesive mounting.
5.1 Yiyan ipo kan
- Install smoke detectors on every level of your home, including basements and attics.
- Place detectors inside each bedroom and outside every sleeping area.
- Mount on the ceiling in the center of the room or hallway. If ceiling mounting is not possible, mount on a wall, 10-30 cm (4-12 inches) from the ceiling.
- Avoid placing detectors near windows, doors, or air vents where drafts could interfere with smoke detection.
- Keep detectors away from kitchens, bathrooms, and garages to prevent false alarms from cooking fumes, steam, or exhaust.
5.2 Magnetic Adhesive Mounting (Recommended for easy installation)
- Clean the ceiling or wall surface where the detector will be installed. Ensure it is dry and free of dust or grease.
- Peel off the protective film from one side of the 3M adhesive pad and attach it firmly to the back of the magnetic mounting plate.
- Peel off the protective film from the other side of the 3M adhesive pad and press the magnetic mounting plate firmly onto the chosen ceiling or wall location for at least 30 seconds.
- Align the smoke detector with the magnetic mounting plate and attach it. The magnets will hold the detector securely in place.
5.3 dabaru iṣagbesori
- Choose a suitable location on the ceiling or wall.
- Use the mounting plate as a template to mark the positions for drilling two holes.
- Lu awọn iho ki o si fi awọn pilogi odi.
- Secure the mounting plate to the ceiling/wall using the provided screws.
- Mu aṣawari ẹfin pọ pẹlu awo iṣagbesori ki o si yi lọla aago aago titi ti o fi tẹ si aaye.

Image: Step-by-step guide for magnetic mounting of the DAYTECH Smoke Detector, showing adhesive application, plate attachment to ceiling, and detector placement.
6. Isẹ
6.1 Ibẹrẹ Ibẹrẹ
The smoke detector is active once installed. The integrated battery is designed for 10 years of operation. A small LED indicator will flash approximately every 50 seconds to confirm the unit is functioning correctly.
6.2 Idanwo Itaniji naa
It is recommended to test your smoke detector weekly to ensure proper functionality.
- Press and hold the large central test/mute button on the detector for a few seconds.
- The alarm will sound loudly (85 dB) and the LED will flash rapidly.
- Release the button to stop the alarm. If the alarm does not sound, refer to the Troubleshooting section.

Image: A hand pressing the central test button on the DAYTECH Smoke Detector, illustrating the easy operation for testing or muting the alarm.
6.3 Muting False Alarms
In case of a non-emergency alarm (e.g., from cooking fumes), you can temporarily silence the alarm:
- Press the central test/mute button once.
- The alarm will be silenced for approximately 10 minutes. The LED will continue to flash every 10 seconds during this period.
- After the mute period, if smoke is still detected, the alarm will reactivate.
6.4 Low Batiri Ikilọ
When the battery is nearing the end of its 10-year life, the detector will emit a 'DI' sound and a red LED will flash every 50 seconds. This indicates that the detector needs to be replaced.
7. Itọju
7.1 Ninu
Dust and debris can affect the performance of your smoke detector. Clean it regularly:
- Fi pẹ̀lẹ́pẹ̀lẹ́ fa omi ìta ohun tí ó ń ríran náà mọ́ra nípa lílo ohun èlò ìfọṣọ onírọ̀rùn.
- Wipe the surface with a slightly damp asọ. Ma ṣe lo awọn sprays mimọ tabi awọn olomi.
- Clean at least once a month, or more frequently if dust accumulates quickly.
7.2 Batiri Rirọpo
The DAYTECH AJ-762 Smoke Detector features a sealed 10-year battery that is not user-replaceable. When the low battery warning sounds, the entire unit must be replaced.
7.3 Rirọpo oluwari
Smoke detectors have a limited lifespan. It is recommended to replace your DAYTECH AJ-762 Smoke Detector every 10 years from the date of manufacture or installation, even if it appears to be functioning correctly.
8. Laasigbotitusita
| Isoro | Owun to le Fa | Ojutu |
|---|---|---|
| Olùṣàwárí kò ní ìkìlọ̀ nígbà ìdánwò. | Unit is faulty or battery is depleted. | Ensure the unit is properly activated. If not, replace the detector. |
| Awọn itaniji eke loorekoore. | Improper placement (near kitchen, bathroom, vents) or dust accumulation. | Relocate the detector to a more suitable area. Clean the detector as per maintenance instructions. Use the mute function for temporary non-emergency alarms. |
| Detector chirps or flashes red LED every 50 seconds. | Ikilọ batiri kekere. | The 10-year battery is depleted. Replace the entire smoke detector unit. |
| Alarm sounds continuously without visible smoke. | Dust, insects, or high humidity. | Clean the detector. If the problem persists, consider relocating or replacing the unit. |
9. Awọn pato
| Ẹya ara ẹrọ | Sipesifikesonu |
|---|---|
| Nọmba awoṣe | AJ-762 |
| Awọn iwọn (L x W x H) | 11 x 11 x 4 cm (4.33 x 4.33 x 1.57 inches) |
| Iwọn | 209.98 giramu |
| Orisun agbara | 10-Year Sealed Lithium Battery (1 C-type included) |
| Iwọn didun itaniji | 85 dB ní mítà 3 |
| Sensọ Iru | Aworan ina |
| Awọn iwọn otutu ti nṣiṣẹ | 0°C si 40°C (32°F si 104°F) |
| Awọn iwe-ẹri | TÜV Rheinland, EN 14604:2005, EN14604 2005/AC:2008 |
| Ohun elo | Ina-retardant ABS |
10. Atilẹyin ọja ati Support
The DAYTECH AJ-762 Smoke Detector comes with a 10-year warranty, ensuring reliable performance and peace of mind. For any questions, technical support, or warranty claims, please contact DAYTECH customer service through your purchase platform or the official DAYTECH webojula.