This manual provides essential instructions for the safe and effective use of your KAIWEETS KM100 Digital Multimeter and KET20 Silicone Multimeter Test Leads. Please read this manual thoroughly before operation and retain it for future reference. The KM100 is designed for measuring AC/DC Voltage, DC Current, Resistance, Continuity, and Diode. The KET20 test leads offer high safety and durability for various electrical testing applications.

Image 1.1: KAIWEETS KM100 Digital Multimeter and KET20 Silicone Test Leads. The image displays the black digital multimeter on the left and the red and black silicone test leads on the right.
2. Alaye Aabo
WARNING: Electrical shock hazard. Improper use can result in injury or death. Always follow safety precautions.
- Ensure the rotary switch is set to the correct measurement range before connecting the test leads.
- Do not attempt to measure AC current with the KM100 multimeter, as it is designed for DC current only.
- The KET20 test leads are rated for CAT III 1000V and CAT IV 600V. Always use appropriate Personal Protective Equipment (PPE).
- Inspect test leads for damage before each use. Do not use if insulation is cracked or damaged.
- Má ṣe kọjá iye ìtẹ̀síwájú tó pọ̀ jùlọ fún gbogbo ìwọ̀n.
- Always disconnect power to the circuit before making resistance, continuity, or diode measurements.

Aworan 2.1: Ẹyin view of the KAIWEETS KM100 Digital Multimeter, showing the kickstand and a warning label regarding electrical safety and proper usage.
3. Ọja Ipariview
3.1 KAIWEETS KM100 Digital Multimeter
The KM100 features a clear digital display, a rotary switch for function selection, and input jacks for test leads. It includes a data hold function and a backlight for visibility in dim conditions.
3.2 KAIWEETS KET20 Silicone Multimeter Test Leads
The KET20 test leads are constructed from temperature-resistant soft silicone, ensuring flexibility and durability. They feature 2mm ultra-fine gold-plated probes for precision and 4mm banana plugs for universal compatibility. The leads are 48 inches long.

Aworan 3.1: alaye view of the KET20 test leads, highlighting features such as the 0.7mm tip, silicone material, 4mm banana plug, and 120cm length. The image also shows the CAT IV 600V and CAT III 1000V ratings.

Image 3.2: Close-up of the KET20 test leads, illustrating their flexible silicone material, high-purity copper wire, and gold-plated probes.
4. Eto
- Fi Awọn batiri sii: Open the battery compartment on the back of the KM100 multimeter and insert the required batteries, observing polarity.
- So awọn itọsọna idanwo pọ:
- Fi asiwaju idanwo dudu sinu jaketi 'COM' (wọpọ).
- Fun ọpọlọpọ awọn wiwọn (Iwọn didun)tage, Resistance, Diode, Continuity), insert the red test lead into the 'VΩmA' jack.
- For DC Current measurements up to 10A, insert the red test lead into the '10A' jack.
- Agbara Tan: Turn the rotary switch from 'OFF' to the desired measurement function.
5. Awọn ilana Iṣiṣẹ
5.1 AC Voltage Idiwon
Lati wiwọn AC voltage:
- Set the rotary switch to the 'V~' (AC Voltage) ibi tí a ti lè rí i.
- Connect the red test lead to the 'VΩmA' jack and the black test lead to the 'COM' jack.
- Carefully touch the probes to the points where you want to measure AC voltage.
- Ka iye lori ifihan.

Image 5.1: The KAIWEETS KM100 Multimeter displaying an AC voltage reading while probes are inserted into a wall outlet. Note: This meter cannot be used to test AC current.
5.2 DC Voltage Idiwon
Lati wiwọn DC voltage:
- Set the rotary switch to the 'V-' (DC Voltage) ibi tí a ti lè rí i.
- Connect the red test lead to the 'VΩmA' jack and the black test lead to the 'COM' jack.
- Touch the red probe to the positive side and the black probe to the negative side of the DC source.
- Ka iye lori ifihan.

Image 5.2: The KAIWEETS KM100 Multimeter displaying a DC voltage reading while probes are connected to an automotive battery.
5.3 Ìwọ̀n Ìsinsìnyí DC
To measure DC current (up to 10A):
- IKILO: Ensure the circuit is de-energized before connecting the meter in series.
- Set the rotary switch to the 'A-' (DC Current) range.
- Connect the red test lead to the '10A' jack and the black test lead to the 'COM' jack.
- Open the circuit where current is to be measured and connect the meter in series.
- Re-energize the circuit and read the value.
5.4 Resistance Wiwọn
Lati wiwọn resistance:
- IKILO: Rí i dájú pé agbára ìṣiṣẹ́ náà ti dínkù, àti pé gbogbo àwọn capacitors ti tú jáde kí wọ́n tó wọn resistance.
- Set the rotary switch to the 'Ω' (Resistance) range.
- Connect the red test lead to the 'VΩmA' jack and the black test lead to the 'COM' jack.
- Touch the probes across the component or circuit segment.
- Ka iye lori ifihan.
5.5 Igbeyewo Ilọsiwaju
Láti ṣe ìdánwò ìtẹ̀síwájú:
- IKILO: Ensure the circuit is de-energized before testing continuity.
- Set the rotary switch to the '♪' (Continuity) range.
- Connect the red test lead to the 'VΩmA' jack and the black test lead to the 'COM' jack.
- Touch the probes across the component or wire.
- If there is continuity (low resistance), the meter will emit an audible beep and display a low resistance value.

Image 5.3: The KAIWEETS KM100 Multimeter performing a continuity test on a wire, indicated by a 'buzz' sound effect shown in the image.
5.6 Diode Idiwon
To measure diodes:
- IKILO: Ensure the circuit is de-energized before testing diodes.
- Set the rotary switch to the '→|→' (Diode) range.
- Connect the red test lead to the 'VΩmA' jack and the black test lead to the 'COM' jack.
- Touch the red probe to the anode and the black probe to the cathode of the diode.
- Ka siwaju voltage drop on the display. Reverse the probes to check for an open circuit (OL) reading.
6. Itọju
- Ninu: Nu mita naa ki o si da idanwo awọn okun pẹlu ipolowoamp asọ. Ma ṣe lo abrasive ose tabi epo.
- Rirọpo Batiri: Rọpo awọn batiri nigbati itọka batiri kekere ba han loju iboju.
- Rirọpo Fuse: The KM100 features double fuses for anti-burn protection. If the meter stops functioning in a current range, the fuse may need replacement. Refer to the full product manual for fuse specifications and replacement instructions.
- Ibi ipamọ: Store the multimeter and test leads in a cool, dry place, away from direct sunlight and extreme temperatures. The included case provides protection during storage and transport.

Image 6.1: Illustration of the KET20 test leads' durability, high temperature resistance, safety features, convenience, and universal compatibility.

Image 6.2: Demonstrates the heat-resistant and corrosion-resistant properties of the silicone test leads, showing them exposed to flame and in a snowy environment, highlighting their suitability for extreme conditions.
7. Laasigbotitusita
- No Display/Weak Display: Ṣàyẹ̀wò fífi bátìrì sílẹ̀ kí o sì gba agbára. Rọpò bátìrì tí ó bá pọndandan.
- Awọn kika ti ko tọ:
- Ensure the rotary switch is set to the correct function and range.
- Verify test lead connections to the correct input jacks.
- Ṣàyẹ̀wò fún àwọn ìtọ́wò tàbí àwọn ìwádìí tí ó bàjẹ́.
- Ko si Iwọn Lọwọlọwọ: Check if the fuse for the current range is blown. Replace if needed (refer to full manual).
- Continuity Test Not Beeping: Rí i dájú pé agbára ìṣiṣẹ́ náà kò pọ̀. Ṣàyẹ̀wò fún ìṣiṣẹ́ tí ó ṣí sílẹ̀ tàbí agbára gíga.
8. Awọn pato
| Ẹya ara ẹrọ | Sipesifikesonu |
|---|---|
| Brand | KAIWEETS |
| Awoṣe | KM100 (Multimeter), KET20 (Test Leads) |
| Awọn iṣẹ wiwọn | AC/DC Voltage, DC Current, Resistance, Continuity, Diode |
| Safety Rating (Test Leads) | CAT III 1000V, CAT IV 600V, 20A |
| Test Lead Material | Silikoni |
| Iwadi Iru | 2mm Ultra-Fine Gold-Plated |
| Gígùn Ìdánwò Ìdarí | 48 inches (120cm) |
| Orisun agbara | Corded Electric (refers to the power source for the device being tested, not the multimeter itself which is battery-powered) |
| Àwọ̀ | Dudu |
| Akọkọ Wa Ọjọ | Oṣu Kẹta Ọjọ 11, Ọdun 2025 |
9. Atilẹyin ọja ati Support