1. Ifihan
The EARU Electric Single Phase Energy Meter (Model EARU-1006) is designed for accurate monitoring of electrical parameters in single-phase 220V, 80A systems. It provides real-time data for voltage (V), current (A), power (W), power factor (PF), frequency (Hz), and kilowatt-hour (kWh) consumption. This device assists in understanding energy usage and identifying potential inefficiencies in your electrical system.
2. Alaye Aabo
- Onímọ̀ ẹ̀rọ iná mànàmáná tó mọ̀ nípa rẹ̀ gbọ́dọ̀ ṣe iṣẹ́ rẹ̀ ní ìbámu pẹ̀lú àwọn òfin àti ìlànà iná mànàmáná agbègbè.
- Ensure the main power supply is disconnected before installation or maintenance to prevent electric shock.
- Ma ṣe ṣiṣẹ ẹrọ ti o ba han pe o bajẹ.
- This device is designed for indoor use in a dry environment. Avoid exposure to moisture or extreme temperatures.
- The maximum current rating is 80A. Do not exceed this limit.
3. Ọja Ipariview
The EARU-1006 energy meter features a clear LCD display that shows various electrical parameters simultaneously. It is designed for DIN rail mounting, allowing for easy integration into standard electrical distribution boards.

olusin 1: Iwaju view of the EARU Electric Single Phase Energy Meter, showing the LCD display with various electrical readings.

Nọmba 2: Alaye view of the LCD display, illustrating the layout of voltage, current, power, frequency, power factor, and kWh readings.
4. Package Awọn akoonu
Ni igbagbogbo package naa pẹlu:
- 1 x EARU Electric Single Phase Energy Meter (Model EARU-1006)
5. Awọn pato

Figure 3: Technical data table providing detailed specifications of the energy meter.
| Paramita | Iye |
|---|---|
| Brand | ERU |
| Awoṣe | EARU-1006 |
| Oṣuwọn Voltage | AC110V/220V (230 Volts) |
| Ti won won Lọwọlọwọ | 80A |
| Igbohunsafẹfẹ | 50/60Hz |
| Yiye wiwọn | ±1% / Class 1 |
| Agbara agbara | <2W |
| Fifi sori ẹrọ | 35mm DIN Rail |
| Awọn iwọn otutu ṣiṣẹ | -10°C si +55°C |
| Ibi ipamọ otutu | -40°C si +70°C |
| Ọriniinitutu ṣiṣẹ | 5% si 95% RH |
| Ifihan Iru | LCD |
| Max kWh Record | 999999kWh |
| Ọja Mefa | 10 x 5 x 10 cm |
| Iwọn Nkan | 450 g |

Figure 4: Dimensional drawing of the energy meter, showing measurements in both millimeters and inches.
6. Eto ati fifi sori
Pataki: Rii daju pe gbogbo agbara ti ge asopọ ṣaaju ki o to tẹsiwaju pẹlu fifi sori ẹrọ.
- Iṣagbesori: The EARU-1006 is designed for 35mm DIN rail mounting. Snap the meter onto the DIN rail securely within your electrical panel.
- Asopọmọra: Refer to the wiring diagram below for correct connection. This is a single-phase, 2-wire direct connection meter.
- Connect the Live (L) input wire to the designated 'L In' terminal.
- Connect the Neutral (N) input wire to the designated 'N In' terminal.
- Connect the Live (L) output wire to the designated 'L Out' terminal.
- Connect the Neutral (N) output wire to the designated 'N Out' terminal.
- Agbara Tan: Once all connections are secure and verified, restore power to the circuit. The LCD display should illuminate and begin showing readings.

Figure 5: Wiring diagram illustrating the correct connections for the single-phase energy meter.
7. Awọn ilana Iṣiṣẹ
The energy meter operates automatically once powered on. The LCD display continuously cycles through or shows multiple parameters simultaneously.
- Reading Parameters: The display shows Voltage (V), Current (A), Power (W), Power Factor (PF), Frequency (Hz), and Kilowatt-hour (kWh).
- kWh Reading: The meter records total kWh consumption. This reading is permanent and accumulates over time.
- Túnṣe kWh: The meter features a manual reset function for the kWh reading. Consult the device's physical buttons or specific instructions on the meter itself for the reset procedure. Typically, a long press on a designated button (if present) will reset the temporary kWh value. The total kWh value is usually non-resettable.
8. Itọju
- Ninu: Use a soft, dry cloth to clean the meter's exterior. Do not use abrasive cleaners or solvents.
- Ayewo: Periodically inspect the wiring connections to ensure they are tight and free from corrosion.
- Ayika: Rii daju pe agbegbe iṣẹ wa laarin iwọn otutu ti a sọ ati awọn sakani ọriniinitutu.
9. Laasigbotitusita
| Isoro | Owun to le Fa | Ojutu |
|---|---|---|
| Ifihan jẹ òfo | Kò sí ìpèsè agbára; Wáyà tí kò tọ́ | Check power connections and ensure power is supplied. Verify wiring against the diagram. |
| Awọn kika ti ko tọ | Incorrect wiring; Faulty connection | Double-check all wiring connections. Ensure wires are securely fastened. |
| kWh not accumulating | No load connected; Meter malfunction | Ensure there is an active electrical load connected through the meter. If problem persists, contact support. |
10. Atilẹyin ọja ati Support
The EARU Electric Single Phase Energy Meter (Model EARU-1006) typically comes with a 1-year warranty from the date of purchase. Please retain your purchase receipt for warranty claims.
For technical support, troubleshooting assistance, or warranty inquiries, please contact your retailer or the manufacturer directly. Refer to the product packaging or manufacturer's webaaye fun awọn alaye olubasọrọ.