Ọrọ Iṣaaju
The Fluke 107 is a compact, handheld digital multimeter designed for basic electrical measurements. It provides accurate readings for voltage, current, resistance, capacitance, frequency, and duty cycle, along with continuity and diode test functions. Its portable design makes it suitable for various applications, from professional use to hobbyist projects.

Aworan: Iwaju view of the Fluke 107 Digital Multimeter, displaying its screen, rotary dial, and function buttons.
Alaye Aabo
Máa tẹ̀lé àwọn ìlànà ààbò nígbà gbogbo nígbà tí o bá ń lo àwọn ohun èlò ìdánwò iná mànàmáná. Àìṣe bẹ́ẹ̀ lè fa ìpalára tàbí ìbàjẹ́ sí mita tàbí ohun èlò tí a ń dán wò.
- Maṣe ṣe lo diẹ sii ju iwọn didun ti a fun ni idiyele lọtage, as specified in the specifications section, between terminals or between any terminal and earth ground.
- Maṣe ṣe use the meter if it is damaged or operating abnormally. Inspect the case and test leads before use.
- Maṣe ṣe use the meter around explosive gas, vapor, or in damp tabi awọn agbegbe tutu.
- Máa lo àwọn ebute, iṣẹ́ àti ìwọ̀n tó yẹ nígbà gbogbo fún àwọn ìwọ̀n rẹ.
- Ṣọ́ra nígbà tí o bá ń ṣiṣẹ́ pẹ̀lú voltages loke 30V AC RMS, 42V tente oke, tabi 60V DC. Awọn wọnyi ni voltages duro a mọnamọna ewu.
- Ge asopọ agbara iyika ati idasilẹ gbogbo iwọn-gigatage capacitors ṣaaju idanwo resistance, ilosiwaju, diodes, tabi capacitance.
- Ensure the test leads are fully seated in the meter's input jacks.
- Rọpo batiri naa lẹsẹkẹsẹ nigbati ifihan batiri kekere ba han lati rii daju pe o peye.
Ohun ti o wa ninu Apoti
The Fluke 107 package typically includes the following components:
- Fluke 107 Digital Multimeter
- TL75 Test Leads (Hard Point Test Leads)
- 2 AAA Batteries (Installed)
- Smart Strap Magnetic Lanyard
- User Manual (printed safety information booklet)

Image: The Fluke 107 Multimeter displayed alongside its included test leads and magnetic lanyard.
Ṣeto
Fifi sori batiri
The Fluke 107 comes with two AAA batteries pre-installed. If replacement is needed:
- Rii daju pe multimeter ti wa ni pipa.
- Wa yara batiri ni ẹhin mita naa.
- Open the battery compartment cover by twisting the lock and sliding it open.
- Remove the old batteries and insert two new AAA batteries, observing the correct polarity (+/-).
- Pa ideri batiri naa ni aabo.
Nsopọ Awọn Itọsọna Idanwo
The Fluke 107 has three recessed banana jacks:
- A: For current measurements (up to 10A).
- COM: Common terminal for all measurements (black test lead).
- VΩHz: Fún ìdìpọ̀tage, resistance, capacitance, frequency, and diode tests (red test lead).
Always connect the black test lead to the COM jack. Connect the red test lead to the appropriate jack based on the measurement you intend to perform.
Using the Smart Strap Magnetic Lanyard
The included Smart Strap allows for hands-free operation by attaching the meter to a ferrous metal surface or by configuring it as a stand. The strap has a slot that fits into the meter's case and secures with Velcro. The magnetic end can then be used to attach the meter to metal surfaces or to itself to form a viewiduro ing.
Awọn ilana Iṣiṣẹ
Awọn Iṣakoso Loriview
The Fluke 107 features a central rotary selector knob and three soft-touch buttons:
- Rotari Selector koko: Used to select the desired measurement function (OFF, AC Volts, DC Volts, AC mV, Ohms/Continuity/Diode, Capacitance, AC/DC Amps).
- Bọtini MU: Freezes the current reading on the display. Press again to resume live readings.
- Hz % Button: Toggles between frequency (Hz) and duty cycle (%) display when measuring AC Volts or AC Amps.
- Yellow Function Button:
- In AC/DC Amps mode: Toggles between AC and DC current measurement.
- In Ohms mode: Toggles between resistance, continuity test, and diode test.
- Bọtini ina afẹyinti: Activates or deactivates the display backlight. The backlight automatically turns off after 2 minutes of inactivity, but this can be overridden.

Image: A gloved hand adjusting the rotary dial of the Fluke 107 Multimeter, demonstrating its ergonomic design.
Awọn iṣẹ wiwọn
The meter is auto-ranging by default for most functions, simplifying operation.
- Voltage Wiwọn (AC/DC):
- Yipada bọtini Rotari si V~ fun AC voltage tabi V- fun DC voltage.
- Connect the red test lead to the VΩHz jack and the black test lead to the COM jack.
- Apply the test probes across the circuit or component to measure voltage.
- Current Measurement (AC/DC):
- Yipada bọtini Rotari si A~ (AC) or A- (DC). Use the yellow button to toggle between AC and DC if needed.
- Connect the red test lead to the A (10A FUSED) jack and the black test lead to the COM jack.
- Pataki: Connect the meter in series with the circuit to measure current. Ensure the circuit is de-energized before connecting the meter.
- Wiwọn Atako (Ω):
- Yipada bọtini Rotari si Ω.
- Connect the red test lead to the VΩHz jack and the black test lead to the COM jack.
- Apply the test probes across the component. Ensure the circuit is de-energized.
- Igbeyewo Ilọsiwaju:
- Yipada bọtini Rotari si Ω. Press the yellow button until the continuity icon (speaker symbol) appears.
- Connect the red test lead to the VΩHz jack and the black test lead to the COM jack.
- A continuous beep indicates a complete circuit (resistance less than 70Ω). "OL" indicates an open circuit.
- Idanwo Diode:
- Yipada bọtini Rotari si Ω. Press the yellow button until the diode icon (arrow with line) appears.
- Connect the red test lead to the VΩHz jack and the black test lead to the COM jack.
- Place the red probe on the anode and black probe on the cathode of the diode. The display shows the forward voltage drop. Reverse the probes; "OL" should be displayed for a good diode.
- Iwọn Iwọn agbara:
- Turn the rotary knob to the capacitance symbol (-||-).
- Connect the red test lead to the VΩHz jack and the black test lead to the COM jack.
- Pataki: Discharge capacitors before connecting them to the meter. Apply probes across the capacitor. Readings may take up to 18 seconds to stabilize.
- Frequency (Hz) and Duty Cycle (%) Measurement:
- Select AC Volts or AC Amps iṣẹ.
- Tẹ awọn Hz% button to display frequency. Press again for duty cycle. Press a third time to return to voltage/current display.
Aifọwọyi Agbara-Paa
The meter automatically powers off after 20 minutes of inactivity to conserve battery life. This feature can be disabled if continuous operation is required.
Itoju
Ninu
Pa ọran naa pẹlu ipolowoamp Aṣọ àti ọṣẹ ìfọṣọ díẹ̀. Má ṣe lo àwọn ohun ìfọṣọ tàbí àwọn ohun tí ó ń yọ́ nǹkan. Jẹ́ kí ìbòjú náà mọ́ tónítóní kí ó má sì jẹ́ kí ó gbóná.
Batiri Rirọpo
Refer to the "Battery Installation" section under Setup for detailed instructions. Replace batteries when the low battery indicator appears on the display.
Fuse Check and Replacement
The Fluke 107 has a single internal fuse for the Amps function. To check the fuse:
- Yipada yiyan si awọn Ω ipo.
- Plug the red test lead into the VΩHz jack.
- Insert the probe tip of the red test lead into the A (10A FUSED) jack until electrical contact is made.
- A reading of less than 0.5Ω indicates a good fuse. An "OL" reading indicates a blown fuse that requires replacement.
Fuse replacement requires opening the meter case by removing three screws. It is recommended that fuse replacement be performed by qualified personnel or a Fluke service center.
Laasigbotitusita
| Isoro | Owun to le Fa | Ojutu |
|---|---|---|
| "OL" (Àfikún) tí a fi hàn | Input value exceeds selected range; open circuit in continuity/diode test; blown fuse in current mode. | Ensure correct function/range is selected. Check for open circuits. Check fuse in current mode. |
| Ko si ifihan tabi baibai àpapọ | Low battery; meter off; damaged display. | Replace batteries. Turn meter ON. Contact service if display is damaged. |
| Awọn kika ti ko pe | Low battery; incorrect function/range; poor test lead connection; external interference. | Replace batteries. Verify function/range. Ensure leads are fully inserted. Move away from strong electromagnetic fields. |
| Ko si wiwọn lọwọlọwọ | Blown fuse; incorrect connection (not in series). | Check and replace fuse if necessary. Ensure meter is connected in series with the circuit. |
Awọn pato
| Paramita | Iye |
|---|---|
| Max Iwọntage laarin eyikeyi ebute oko ati ilẹ ayé | 600V |
| Ifihan Oṣuwọn imudojuiwọn | 3 updates per second |
| Batiri Iru | 2 x AAA batteries (Alkaline or Lithium recommended) |
| Igbesi aye batiri | Awọn wakati 200 kere |
| Awọn iwọn otutu ti nṣiṣẹ | 0°C si 40°C (32°F si 104°F) |
| DC Volts Ranges | 6.000V, 60.00V, 600.0V (Accuracy: 0.5% + 3 counts) |
| AC Volts Ranges | 6.000V, 60.00V, 600.0V (Accuracy: 1% + 3 counts) |
| ACmV Range | 600.0mV (Accuracy: 3% + 3 counts) |
| DC Amps Ranges | 4.000A, 10.00A (Accuracy: 1.5% + 3 counts) |
| AC Amps Ranges | 4.000A, 10.00A (Accuracy: 1.5% + 3 counts) |
| Awọn sakani Idojukọ | 400.0Ω, 4.000kΩ, 40.00kΩ, 400.0kΩ, 4.000MΩ, 30.00MΩ (Accuracy: 0.5% + 2 or 3 counts, 1.5% + 3 counts for 40MΩ) |
| Capacitance Ranges | 50.00nF, 500.0nF, 5.000µF, 50.00µF, 500.0µF, 1000µF (Accuracy: 2% + 5 counts on two lowest, 5% + 5 counts on higher) |
| Awọn sakani igbohunsafẹfẹ | 50.00Hz, 500.0Hz, 5.000kHz, 50.00kHz, 100.0kHz (Accuracy: 0.1% + 3 counts) |
| Ojuse Cycle | 1% ~ 99% (Accuracy: 1% typical) |
| Diode Test Range | 2.000V (Accuracy: 10%) |
| Ọja Mefa | 8.27 x 11 x 2.17 inches; 7.05 iwon |
Atilẹyin ọja ati Support
The Fluke 107 Digital Multimeter comes with a 1-year manufacturer warranty. For warranty claims, technical support, or service, please contact Fluke customer service or visit the official Fluke website. Ensure you have your product model number and purchase details available.
For additional resources and detailed user manuals, please refer to the official Fluke support channels.