1. Ifihan
The ZIBOO ET1013 Digital Manometer is a precision instrument designed for measuring gauge and differential pressure in various applications. It offers 11 selectable pressure units and features data hold, recording, and zero functions for accurate and reliable measurements. This manual provides essential information for the safe and effective use of your manometer.
2. Alaye Aabo
Maa tẹle awọn iṣeduro aabo wọnyi nigbagbogbo lati yago fun ipalara ati ibajẹ si ohun elo naa:
- Maṣe kọja iwọn titẹ ti o pọju ti ẹrọ naa.
- Ensure proper connection of pressure tubes to avoid leaks or disconnections during operation.
- Keep the device away from extreme temperatures, humidity, and corrosive environments.
- Do not attempt to disassemble or modify the instrument. Refer servicing to qualified personnel.
- Yọ awọn batiri kuro ti ẹrọ naa kii yoo lo fun akoko ti o gbooro sii.
3. Package Awọn akoonu
Jẹrisi pe gbogbo awọn ohun kan wa ninu package:
- 1 x ZIBOO ET1013 Digital Manometer
- 1 x Apo Irinṣẹ
- 1 Pair x RMA316 Manometer Tube Adapter
- 4 x Soft Tubes
- 1 x Itọsọna olumulo

Figure 3.1: Contents included in the ZIBOO ET1013 package.
4. Ọja Ipariview
4.1. Ìṣètò Ẹ̀rọ àti Àwọn Iṣẹ́ Rẹ̀

olusin 4.1: Iwaju view of the ZIBOO ET1013 Digital Manometer with key functions labeled.
- Bọtini UNIT: Cycles through 11 selectable pressure units.
- Bọtini Dimu: Freezes the current displayed reading. Press again to release.
- DIF Button: Activates differential pressure mode, displaying the difference between two pressure inputs.
- Bọtini REC: Enters recording mode to view maximum, minimum, and average values. Long press to exit.
- Bọtini Imọlẹhin: Toggles the LCD backlight on/off for improved visibility in low-light conditions.
- Bọtini agbara: Tan ẹrọ naa si tan tabi pa.
4.2. LCD Ifihan Interface

Nọmba 4.2: Alaye view of the LCD display showing various indicators and readings.
The large LCD display provides clear readings, including:
- Differential Pressure Mode indicator.
- Hold Data indicator.
- Pressure Measurement value.
- MIN/MAX/AVG recording mode indicators.
- Selected Pressure Unit.
4.3. Dual Channel Inputs

Figure 4.3: The dual channel input ports for pressure measurement.
The manometer features two input ports for measuring differential pressure. These ports are clearly marked with '+' and '-' for positive and negative pressure connections.
4.4. Awọn iwọn

Figure 4.4: Physical dimensions of the ZIBOO ET1013 Digital Manometer.
The compact and slim design (approximately 5.79" x 2.16" x 1.26") allows for easy one-handed operation and portability.
5. Eto
5.1. Fifi sori batiri
The ZIBOO ET1013 Manometer requires a 9V battery (not included). To install:
- Wa ideri iyẹwu batiri ni ẹhin ẹrọ naa.
- Use a small screwdriver to open the battery compartment.
- Insert a new 9V battery, ensuring correct polarity.
- Pa ideri batiri naa ni aabo.
Video 5.1: Unboxing and battery installation for a similar digital manometer. This demonstrates the general process for installing the 9V battery.
5.2. Connecting Pressure Tubes
Connect the provided soft tubes to the manometer's input ports and to the pressure source you wish to measure.
- Attach one end of a soft tube to the '+' port on the manometer.
- Attach the other end of the tube to the high-pressure side of your system.
- For differential pressure, attach a second soft tube to the '-' port and to the low-pressure side of your system.
- Use the RMA316 tube adapters if required for specific connections.

Olusin 5.2: Example of connecting a soft tube to a pagoda pressure connector.
6. Awọn ilana Iṣiṣẹ
6.1. Agbara Tan / Paa
Tẹ awọn Agbara button to turn the manometer on. The device will perform a self-test and display readings. To turn off, press the Agbara button again. The device features an auto power-off function after 20 minutes of inactivity to conserve battery life.
6.2. Aṣayan Unit
Tẹ awọn UNIT button to cycle through the 11 available pressure units (e.g., psi, kPa, bar, inHg, mmHg, inH₂O, ftH₂O, cmH₂O, ozin², kgfcm², mbar). The selected unit will be displayed on the LCD.
Video 6.1: Demonstration of unit selection and other basic operations on a digital manometer.
6.3. Idaduro data
Tẹ awọn DIMU button to freeze the current reading on the display. The 'HOLD' indicator will appear. Press the button again to release the hold function and resume live readings.
6.4. Recording (MIN/MAX/AVG)
Tẹ awọn REC button to enter recording mode. The display will show the maximum (MAX), minimum (MIN), and average (AVG) pressure values recorded since entering this mode. Short press the REC button to cycle through MAX, MIN, and AVG values. Long press the REC button for 5 seconds to exit recording mode.
Fidio 6.2: Pariview of features including data recording and unit options on a digital manometer.
6.5. Differential Pressure Measurement
To measure differential pressure, connect the high-pressure source to the '+' port and the low-pressure source to the '-' port. Press the DIF button. The display will show the pressure difference between the two inputs. Pressing the DIF button again will reset the differential measurement to zero, allowing for quick offset correction.
6.6. Imọlẹ ẹhin
Tẹ awọn Imọlẹ ẹhin button (often indicated by a light bulb icon) to turn the LCD backlight on or off. This feature enhances readability in dimly lit environments.
7. Awọn ohun elo
The ZIBOO ET1013 Digital Manometer is suitable for a wide range of professional and industrial applications, including:
- HVAC system diagnostics and maintenance.
- Pneumatic control system testing.
- Medical equipment pressure verification.
- Gas appliance service and installation.
- Laboratory testing and research.
- Computer peripheral pressure monitoring.
- Optimizing production processes in various industries.

Figure 7.1: Diverse applications of the digital manometer in industrial and technical settings.
8. Awọn pato
The following table outlines the technical specifications of the ZIBOO ET1013 Digital Manometer:
| Ẹya ara ẹrọ | Apejuwe |
|---|---|
| Ifihan | LCD meji |
| Yiye | ±0.3%FSO (25°C) |
| Atunṣe | ±0.2% (Max +/-0.5%FSO) |
| Linearity/Hysteresis | ±0.29%FSO |
| Ipa ti o pọju | 10psi (HT-1890) |
| Akoko Idahun | 0.5 Aaya aṣoju |
| Atọka Batiri Kekere | Bẹẹni |
| Ju Range Atọka | Asise.1 |
| Labẹ Range Atọka | Asise.2 |
| Awọn ipo iṣẹ | 32°F si 122°F (0 si 50°C) |
| Awọn ipo ipamọ | 14°F si 140°F (-1 si 60°C) |
| Ibi ti ina elekitiriki ti nwa | 1x 9V Battery (not included) or External 9VDC |
| Standard Awọn ẹya ẹrọ | Apo & Tubing |
| Iwọn Nkan | 300 g |
| Parcel Mefa | 20.6 x 10.9 x 5.69 cm |

Figure 8.1: Parametric indicators of the ZIBOO ET1013 Digital Manometer.
9. Itọju
To ensure the longevity and accuracy of your ZIBOO ET1013 Digital Manometer:
- Ninu: Mu ẹrọ naa nu pẹlu asọ ti o gbẹ. Ma ṣe lo abrasive ose tabi epo.
- Ibi ipamọ: Store the manometer in its protective tool bag in a cool, dry place when not in use. Avoid areas with high humidity or extreme temperatures.
- Batiri: Replace the 9V battery when the low battery indicator appears on the display. Remove the battery if storing the device for extended periods to prevent leakage.
- Tubes and Adapters: Inspect pressure tubes and adapters regularly for wear, cracks, or blockages. Replace them if damaged to maintain measurement integrity.
10. Laasigbotitusita
If you encounter issues with your ZIBOO ET1013 Digital Manometer, refer to the following common problems and solutions:
- Ko si Ifihan/Ẹrọ ti ko tan: Check battery installation and ensure the battery has sufficient charge. Replace the 9V battery if necessary.
- Awọn kika ti ko pe: Ensure pressure tubes are securely connected and free from kinks or leaks. Perform a zero-adjustment if needed (by pressing the DIF button to reset differential measurement). Verify the correct pressure unit is selected.
- 'Err.1' Displayed: Indicates an over-range condition. The measured pressure exceeds the device's maximum capacity. Reduce the applied pressure.
- 'Err.2' Displayed: Indicates an under-range condition. The measured pressure is below the device's minimum capacity.
- Atọka Batiri Kekere: Replace the 9V battery promptly to ensure continued accurate operation.
Fun awọn ọran ti o tẹsiwaju ti ko bo nibi, jọwọ kan si atilẹyin alabara.
11. Atilẹyin ọja ati Support
Specific warranty details and support contact information may vary by region and retailer. Please refer to the documentation provided with your purchase or contact the manufacturer directly for assistance.