This user manual provides detailed instructions for the safe and effective operation of your Hcalory TS-M Thermal Imaging Camera with Multimeter. This device integrates thermal imaging capabilities with a professional-grade digital multimeter, offering a versatile tool for diagnostics and measurement in various applications. Please read this manual thoroughly before using the device and retain it for future reference.
2. Alaye Aabo
Always observe the following safety precautions to prevent injury and avoid damage to the instrument or the equipment under test.
- Má ṣe lo ẹ̀rọ náà bí ó bá hàn pé ó ti bàjẹ́ tàbí tí ìdènà lórí àwọn ìdánwò bá ti bàjẹ́.
- Rí i dájú pé a yan iṣẹ́ àti ìwọ̀n tó yẹ kí a tó ṣe àwọn ìwọ̀n.
- Maṣe kọja awọn ifilelẹ titẹ sii ti o pọju fun iṣẹ eyikeyi.
- Ṣọra pupọ nigbati o ba n ṣiṣẹ pẹlu voltages loke 30V AC RMS, 42V tente oke, tabi 60V DC. Awọn wọnyi ni voltages duro a mọnamọna ewu.
- Ge agbara kuro ninu Circuit naa ki o si tu gbogbo agbara giga kurotagawọn capacitors e ṣaaju ṣiṣe awọn idanwo resistance, ilosiwaju, tabi diode.
- Use only the test leads provided or approved by Hcalory.
- Fi ika ọwọ rẹ si ẹhin awọn aabo ika lori awọn ayẹwo idanwo lakoko lilo.
- Má ṣe lo ẹ̀rọ náà níbi tí afẹ́fẹ́, èéfín, tàbí eruku bá ń gbóná.
- Refer to the specifications section for detailed electrical ratings and environmental conditions.
3. Package Awọn akoonu
Verify that all items listed below are present and undamaged upon opening the package. If any item is missing or damaged, contact your retailer.

Nọmba 3.1: Awọn akoonu Package
The image displays the complete contents of the Hcalory TS-M package. These include (1) an EV Toolkit (carrying case), (2) the Instruction Manual, (3) a USB Charging Cable/Probe, (4) the Thermal Imaging Multimeter 2-in-1 device, (5) Multimeter Probes, and (6) a Macro Magnetic Lens.
- Thermal Imaging Multimeter (Model TS-M)
- Multimeter Test Leads (Probes)
- Okun Ngba agbara USB
- Macro Magnetic Lens
- Ilana itọnisọna
- Carrying Case (EV Toolkit)
4. Ọja Ipariview
The Hcalory TS-M combines a high-resolution thermal imager with a full-function digital multimeter, designed for efficiency and accuracy in various diagnostic tasks. Its robust construction ensures durability in demanding environments.

Figure 4.1: Device Front and Back View
This image shows the Hcalory TS-M device from both the front and back. The front features the display screen, control buttons, and multimeter input jacks. The back includes the IR camera lens and a macro lens attachment point.
Awọn ẹya pataki:
- Integrated Thermal Imaging: High-resolution thermal sensor for visualizing temperature differences.
- Professional Multimeter: Full range of electrical measurement functions including voltage, lọwọlọwọ, resistance, ilosiwaju, ati idanwo diode.
- TISR Resolution: Enhanced thermal imaging resolution of 240x240 pixels for clearer thermal details.
- Macro Lens Capability: Magnetic macro lens for detailed thermal inspection of small components.
- Apẹrẹ alagidi: Built to withstand drops, dust, and water splashes, suitable for tough job sites.
- Igbesi aye batiri gigun: 1500 mAh battery providing up to 7 hours of continuous operation.
5. Eto
5.1 Ngba agbara si Ẹrọ
Before first use, fully charge the Hcalory TS-M. Connect the provided USB charging cable to the device's USB-C port and to a standard USB power adapter (not included) or a computer USB port. The charging indicator on the device will show charging status.

Àwòrán 5.1: Gbígba agbára sí ẹ̀rọ náà
The image illustrates the Hcalory TS-M connected via its USB-C port for charging. The display indicates a full battery and an estimated operational time of 7 hours, powered by its 1500 mAh battery.
5.2 Attaching Test Leads
For multimeter functions, insert the red test lead into the VΩ(+) jack and the black test lead into the COM(-) jack. Ensure a secure connection.
5.3 Attaching Macro Lens (Optional)
For detailed thermal inspection of small components, attach the magnetic macro lens to the designated area on the back of the device, over the IR camera lens. The magnetic attachment ensures easy installation and removal.

Figure 5.2: Macro Lens Attachment
This image demonstrates the Hcalory TS-M with its magnetic macro lens attached to the rear. The display shows a comparison of thermal images, highlighting the enhanced detail provided by the 5x magnification of the macro lens compared to 1x without it, useful for pinpoint accuracy on small components.
6. Awọn ilana Iṣiṣẹ
6.1 Agbara Tan / Pa
Press and hold the power button (usually marked with a circle and a vertical line) to turn the device on or off.
6.2 Thermal Imaging Mode
Upon powering on, the device typically defaults to thermal imaging mode. The screen will display a thermal image of the environment. Use the navigation buttons (up, down, left, right, OK) to access menus and adjust settings such as color palettes, emissivity, and temperature units.

Figure 6.1: Thermal Imaging in Use
The image shows a user holding the Hcalory TS-M, with its screen displaying a thermal image of an engine. This illustrates the device's capability to provide immediate visual temperature data, aiding in quick problem diagnosis.
6.2.1 TISR Resolution Enhancement
The Hcalory TS-M features TISR (Thermal Imaging Super Resolution) technology, enhancing the thermal image resolution to 240x240 pixels for greater clarity. This feature can typically be toggled on or off via the device's menu settings to suit different inspection needs.

Figure 6.2: TISR Resolution Comparison
This image demonstrates the impact of TISR technology. On the left, a thermal image with TISR enabled shows a resolution of 240x240, providing significantly more detail. On the right, the same scene with TISR off displays a lower resolution of 64x64, highlighting the clarity improvement offered by the enhanced resolution feature.
6.3 Multimeter Ipo
To switch to multimeter mode, use the mode selection button or navigate through the menu. Once in multimeter mode, select the desired measurement function (e.g., AC Voltage, DC Voltage, Resistance, Continuity, Diode Test) using the function dial or buttons. Connect the test leads to the circuit under test as appropriate for the selected function.

Figure 6.3: Multimeter Functionality
The image shows the Hcalory TS-M in use as a multimeter, with its probes connected to a circuit board. The screen displays electrical measurement readings, demonstrating its capability for precise electrical diagnostics.
6.3.1 Common Multimeter Functions:
- VoltagÌwọ̀n e (AC/DC): Connect probes in parallel with the component or circuit to measure voltage.
- Iwọn Atako: Ensure the circuit is de-energized. Connect probes across the component to measure resistance.
- Idanwo Ilọsiwaju: For checking if a circuit is complete. The device will typically emit an audible tone if continuity is detected.
- Idanwo Diode: For checking the functionality of diodes.
7. Itọju
7.1 Ninu
Nu ẹrọ naa casing pẹlu ipolowoamp cloth and mild detergent. Do not use abrasive cleaners or solvents. Ensure the device is powered off and disconnected from any power source before cleaning. Do not immerse the device in water.
7.2 batiri Itọju
The device contains a rechargeable lithium-ion battery. For optimal battery life, avoid fully discharging the battery frequently. If storing the device for an extended period, charge it to approximately 50% every few months.
7.3 Fuse Replacement (Multimeter)
The multimeter functions are protected by internal fuses. If a current measurement function fails, the fuse may need replacement. Refer to the specifications for the correct fuse type and rating. Fuse replacement should only be performed by qualified personnel.
8. Laasigbotitusita
| Isoro | Owun to le Fa | Ojutu |
|---|---|---|
| Ẹrọ naa ko ṣiṣẹ. | Batiri kekere tabi dinku. | Gba agbara si ẹrọ nipa lilo okun USB ti a pese. |
| Àwòrán ooru kò hàn gbangba tàbí kò ṣe kedere. | Lens is dirty; TISR is off. | Clean the IR lens with a soft cloth. Enable TISR in settings. |
| Multimeter readings are incorrect or zero. | Incorrect function selected; test leads not properly connected; blown fuse. | Verify function selection. Ensure leads are securely connected. Check and replace fuse if necessary (qualified personnel only). |
| Ẹ̀rọ náà yóò dì tàbí kí ó má ṣe dáhùn. | Aṣiṣe sọfitiwia. | Perform a soft reset by holding the power button for 10-15 seconds. If persistent, a factory reset may be required (refer to advanced settings). |
9. Awọn pato
| Ẹya ara ẹrọ | Sipesifikesonu |
|---|---|
| Awoṣe | TS-M |
| Brand | HCALORY |
| Ipinnu Gbona | 240x240 pixels (with TISR) |
| Iwọn otutu | -68°F to 1022°F (approximately -55°C to 550°C) |
| Batiri Iru | 12V Lithium-ion (included) |
| Agbara Batiri | 1500 mAh (Awọn wakati 5.55 Watt) |
| Akoko Iṣiṣẹ | Titi di wakati 7 |
| Iwọn Nkan | 599 g |
| Package Mefa | 24.41 x 15.09 x 6.71 cm |
| Awọn iṣẹ Multimeter | Voltage (AC/DC), Current, Resistance, Continuity, Diode Test |
| Awọn irinše to wa | Thermal Imaging Camera with Multimeter, Test Leads, USB Cable, Macro Lens, Carrying Case, Manual |
| Ilu isenbale | China |
10. Atilẹyin ọja ati Support
For warranty information and technical support, please refer to the warranty card included with your product or visit the official Hcalory webojula. Tọju iwe-ẹri rira rẹ bi ẹri rira fun awọn iṣeduro atilẹyin ọja.
In case of issues not covered in the troubleshooting section, or for service inquiries, please contact Hcalory customer support.