1. Ifihan
This manual provides detailed instructions for the installation, operation, and maintenance of your TOMZN TOB1S-63 Three Phase 3P+N WiFi Smart Circuit Breaker. This device is designed to provide advanced electrical protection and smart control capabilities for various applications, including solar installations. Please read this manual thoroughly before installation and use to ensure safe and efficient operation.
2. Alaye Aabo
IKILO: Electrical shock hazard. Installation and servicing must be performed by qualified personnel only. Always disconnect power before working on the circuit breaker or associated wiring.
- Ensure the main power supply is OFF before installation or maintenance.
- Verify correct wiring connections to prevent damage to the device and connected equipment.
- Ma ṣe ṣiṣẹ ẹrọ fifọ Circuit ti o ba han pe o bajẹ.
- This device is designed for indoor use or in appropriate enclosures that protect it from direct weather exposure.
3. Ọja Ipariview
The TOMZN TOB1S-63 is a smart circuit breaker offering protection against over-voltage (OVP), labẹ-voltage (UVP), over-current (OCP), and short-circuit conditions. It features WiFi connectivity for remote control via the TUYA Smartlife app and supports RS485 Modbus communication.

olusin 3.1: Iwaju view of the TOB1S-63 Smart Circuit Breaker, showing the main switches, power and load terminals, WiFi antenna, and indicator lights.

olusin 3.2: Angled view highlighting the input (Power) and output (Load) terminals, along with the WiFi antenna connection point.
Awọn eroja pataki:
- Main Switches: Manual ON/OFF control for each phase.
- Awọn ebute agbara: Input connections for the three-phase and neutral lines.
- Load Terminals: Output connections to the protected circuit.
- Eriali WiFi: For wireless communication with the Smartlife app.
- Signal/Light Indicators: Provide status feedback (e.g., power, WiFi connection).
- DIN Rail Mounting Clips: For secure installation on a standard DIN rail.

olusin 3.3: Apa view illustrating the DIN rail mounting clips for easy installation.
4. Eto
4.1 fifi sori ẹrọ
- Ensure all power is disconnected at the main breaker.
- Mount the TOB1S-63 circuit breaker onto a standard 35mm DIN rail by engaging the clips on the back of the device.
4.2 Itanna onirin
The TOB1S-63 is a 3P+N device. Connect the incoming power supply to the 'Power' terminals and the load to the 'Load' terminals as indicated on the device.
- Connect the three phase lines (L1, L2, L3) and the neutral line (N) to the respective 'Power' input terminals.
- Connect the corresponding load lines (L1, L2, L3, N) to the 'Load' output terminals.
- Ensure all screw-type terminals are tightened securely to prevent loose connections and arcing.

olusin 4.1: Top view with a simplified wiring diagram indicating Power (input) and Load (output) connections.
4.3 WiFi Network Connection (TUYA Smartlife App)
- Download the 'TUYA Smartlife' app from your smartphone's app store.
- Forukọsilẹ tabi wọle si akọọlẹ Smartlife rẹ.
- Ensure the circuit breaker is powered ON. The 'Signal' indicator light should be blinking. If not, press and hold the 'Press 10s network' button until it blinks rapidly.
- In the Smartlife app, tap '+' to add a device. Select 'Electrical' > 'Circuit Breaker (Wi-Fi)'.
- Tẹle awọn ilana loju iboju lati so ẹrọ naa pọ mọ nẹtiwọọki WiFi 2.4GHz rẹ.
- Once connected, the 'Signal' indicator will become solid.
4.4 RS485 Modbus Connection (Optional)
For RS485 Modbus communication, connect the A and B terminals of the circuit breaker to your Modbus network. Refer to the Modbus protocol documentation for specific register addresses and communication parameters.
5. Awọn ilana Iṣiṣẹ
5.1 Afowoyi isẹ
To manually turn the circuit breaker ON or OFF, use the red toggle switches on the front panel. Push up for ON, push down for OFF.
5.2 Smartlife App Operation
Once connected to the Smartlife app, you can:
- Remotely turn the circuit breaker ON/OFF.
- Set schedules or timers for automatic operation.
- Monitor real-time current, voltage, ati lilo agbara.
- Adjust protection parameters (OVP, UVP, OCP).
5.3 Idaabobo Awọn ẹya ara ẹrọ
The TOB1S-63 provides the following adjustable protection features:
- Lori Voltage Idaabobo (OVP): Adjustable range 250-300V. The breaker will trip if the voltage exceeds this set limit.
- Labẹ Voltage Idaabobo (UVP): Adjustable range 150-200V. The breaker will trip if the voltage drops below this set limit.
- Over Current Protection (OCP): Adjustable range 1-63A. The breaker will trip if the current exceeds this set limit.
- Idaabobo Iyika kukuru: Non-adjustable, inherent protection against short circuits.
Adjust these settings via the Smartlife app interface for the device. After a trip event, investigate the cause before manually resetting the breaker.
6. Itọju
The TOMZN TOB1S-63 circuit breaker requires minimal maintenance.
- Periodically inspect the wiring connections to ensure they remain tight and free from corrosion.
- Keep the device clean and free from dust and debris. Use a dry, soft cloth for cleaning.
- Má ṣe lo àwọn ohun ìfọṣọ omi tàbí àwọn ohun èlò ìfọṣọ omi.
- Rii daju pe fentilesonu to dara ni ayika ẹrọ lati ṣe idiwọ igbona.
7. Laasigbotitusita
- Ẹrọ ko ṣiṣẹ lori:
- Ṣayẹwo ipese agbara akọkọ.
- Verify all input wiring connections are secure.
- Awọn irin-ajo fifọ Circuit nigbagbogbo:
- Check for over-current conditions on the load.
- Daju voltage levels are within the set OVP/UVP ranges.
- Inspect for short circuits in the connected load.
- Adjust OVP/UVP/OCP settings if necessary, ensuring they are appropriate for your application.
- Awọn iṣoro asopọ WiFi:
- Ensure your router is 2.4GHz compatible.
- Check WiFi signal strength at the device location.
- Restart the circuit breaker and your WiFi router.
- Re-attempt the pairing process in the Smartlife app.
- RS485 Modbus communication failure:
- Verify A and B terminal connections.
- Check Modbus network configuration and device address.
8. Awọn pato
| Ẹya ara ẹrọ | Sipesifikesonu |
|---|---|
| Nọmba awoṣe | TOB1S-63 3P+N |
| Oṣuwọn Voltage | 380VAC (3-Phase) |
| Ti won won Lọwọlọwọ | 1-63A (A le ṣatunṣe) |
| Lori Voltage Adijositabulu Range | 250-300V |
| Labẹ Voltage Adijositabulu Range | 150-200V |
| Asopọmọra | WiFi (2.4GHz), RS485 Modbus |
| Idaabobo Awọn ẹya ara ẹrọ | OVP, UVP, OCP, Short-Circuit |
| Iṣagbesori | 35mm DIN Rail |
| Ijẹrisi | CE |
| Iwọn Nkan | 100 g |
| Awọn iwọn (isunmọ.) | 1 x 1 x 1 cm (Parcel Dimensions) |
9. Atilẹyin ọja ati Support
Fún àlàyé nípa àtìlẹ́yìn àti ìrànlọ́wọ́ ìmọ̀ ẹ̀rọ, jọ̀wọ́ wo àwọn ìwé tí a pèsè pẹ̀lú ohun tí o rà tàbí kí o kan sí olùtajà rẹ. Pa ìwé ẹ̀rí ìrajà rẹ mọ́ gẹ́gẹ́ bí ẹ̀rí ìrajà náà.