Awọn ilana Lilo ọja

Iṣaaju:
ENTTEC Pixel controllers support over 20 default pixel protocols. The custom protocol feature allows users to create a custom protocol for pixel fixtures not covered by default protocols without the need for new firmware.

Awọn ibeere Iṣeto:

  • Datasheet of the desired pixel fixture
  • Computer to access the device settings page
  • For ENTTEC Ethernet Controller: Device IP address (DHCP or static)
  • For DIN PIXIE: EMU Software for configuration

Guide to Custom Protocol Creation:

  1. Verify datasheet for compatible pixel protocol
  2. Navigate to the Device’s User Interface to enablethe  custom protocol feature
  3. Adjustthe  pixel fixture’s data voltage timing viathe  web interface based othe n datasheet

Step 1: Verify Datasheet for Compatible Protocol

  1. Check the data transmission method from the datasheet
  2. Identify data transmission method (e.g., D1-D2-D3…Dn or C1-C2-D1-D2…Dn)
  3. Choose a supported protocol with a similar data transmission method

FIMWARE ibaramu

Ṣiṣẹda ilana aṣa jẹ ifihan ninu awọn olutona piksẹli ENTTEC atẹle:

SKU Ọja Famuwia Ẹya
73539 DIN PIXIE V2.0 tabi loke
70067 PIXELATOR MINI V2.0 tabi loke
70068 PIXELATOR MINI MK2 V1.0 tabi loke
71521 Oṣu Kẹjọ MK2 V4.0 tabi loke
71522 Oṣu Kẹjọ MK3 V1.0 tabi loke

AKOSO

  • ENTTEC Pixel controllers support more than 20 pixel protocols by default. In the event of missing protocol, this custom feature allows users to create a custom protocol for the desired pixel fixture anytime without having to submit a support request for new firmware.
  • Ẹya ara ẹrọ yi kí awọn olumulo lati ṣatunṣe voltage akoko ti o da lori awọn ilana atilẹyin ti ọna gbigbe data ba baamu eyikeyi awọn ilana atilẹyin wa.
  • Iwe yii n pese awọn ilana iṣeto fun ṣiṣẹda ilana piksẹli aṣa ati ijẹrisi awọn ibeere.

Oṣo awọn ibeere

Awọn atẹle ni a nilo lati ṣẹda ilana aṣa kan:

  1. Iwe data: Obtain the datasheet of the desired pixel fixture to gather necessary information. Contact the dealer or manufacturer for this document.
  2. Ẹrọ: Use a computer to access the device settings page.
  3. For the TEC Ethernet Controller: Obtain the device IP address, which can be either DHCP or static, based on your network settings. Discover the IP using the ENTTEC EMU app.
  4. For DIN PIXIE: Use the EMU Software for configuration.

Itọsọna si Aṣa Ilana ẹda

Ẹya ara ẹrọ yii gba awọn olumulo laaye lati ṣatunṣe data voltage timing to meet specific protocol needs. To create a custom protocol:

  1. Daju iwe data fun ilana piksẹli ibaramu.
  2. Lilö kiri si Iboju olumulo ti Ẹrọ lati mu ẹya ara ẹrọ ilana aṣa ṣiṣẹ.
  3. Tun piksẹli imuduro ká data voltage akoko nipasẹ awọn web ni wiwo bi fun awọn olupese ká datasheet.

Igbesẹ 1: Daju iwe data fun ilana ibaramu

  1. Daju ọna gbigbe data ti ilana ti o fẹ lati iwe data naa.
    1. The data transmission method implies how the data is forwarded. Below are demonstrated the common data transmission methods:
      • Ọna ti o wọpọ julọ n gbe data lọ laisi afikun awọn die-die (fun apẹẹrẹ, D1-D2-D3…Dn).
        Example: Alaye sile lati WB2812B ká datasheet

        ENTTEC-73539-DIN-PIXIE-FIG-2

      • Diẹ ninu awọn ilana, bii TM1814, pẹlu afikun data ni iwaju (fun apẹẹrẹ, C1-C2-D1-D2…Dn).
        Example: Alaye sile lati TM1814 ká datasheet

        ENTTEC-73539-DIN-PIXIE-FIG-3

  2. Yan ilana ti o baamu ti ẹrọ naa ṣe atilẹyin (tabi yan lati inu example) that shares the same data transmission method as your desired pixel protocol.
  3. Tẹsiwaju si Igbesẹ 2 fun iṣeto siwaju sii.

Step 2: Navigate to the Device’s Settings page to enable the custom protocol feature
In this step, the OCTO/PIXELATOR MINI Series and Din PIXIE are guided accordingly due to their distinct interfaces.
For ENTTEC Ethernet Controllers (OCTO/PIXELATOR MINI Series)

  1. Access to the OCTO/PIXELATOR MINI web ni wiwo
    1. Google Chrome ti wa ni daba bi awọn web browser to access the OCTO/PIXELATOR MINI’s web ni wiwo.
    2. Free ENTTEC app, EMU can be used to discover OCTO/PIXELATOR MINI’s IP address. See the ENTTEC webaaye www.enttec.com lati ṣe igbasilẹ ohun elo naa.
    3. After entering the IP address of OCTO/PIXELATOR MINI, the user will land on the Home page of OCTO/PIXELATOR MINI’s User Interface.

      ENTTEC-73539-DIN-PIXIE-FIG-4
      Example of the OCTO homepage in Figure 1 indicates IP address 10.10.3.31, which was assigned by the DHCP server. For the out-of-box OCTO/PIXELATOR MINI that is connected directly to a computer (no DHCP server), the default IP address is 192.168.0.10.
      See OCTO/PIXELATOR MINI User Manual ‘Networking’ section for more information.

  2. Navigate to the Settings page – Output Setting.
    Lọ si iṣẹjade nibiti imuduro piksẹli ti o fẹ ti sopọ si. Mu ilana piksẹli kan lati inu atokọ sisọ silẹ ti o pin ọna gbigbe kanna ti o jẹri ni Igbesẹ 1.

    ENTTEC-73539-DIN-PIXIE-FIG-5

  3. Enable Custom protocol (Continue to Step 3)
    Mu apoti ami 'Aṣa' ṣiṣẹ lati wọle si data voltage ìlà setup. Ṣii silẹ lati mu ilana aṣa ṣiṣẹ.

    ENTTEC-73539-DIN-PIXIE-FIG-6

Fun DIN PIXIE

  1. So DIN PIXIE pọ mọ kọnputa nipa lilo USB Iru-B.
  2. Lọlẹ EMU Software.
  3. Ṣayẹwo fun ẹrọ naa ki o tẹ Conf ti DIN PIXIE ti o ṣawari.

    ENTTEC-73539-DIN-PIXIE-FIG-6

  4. Enable Custom Protocol (Continue to Step 3)
    Pick a pixel protocol from the dropdown list that shares the same transmission method verified in tp,1, and enable Custom.

    ENTTEC-73539-DIN-PIXIE-FIG-8

Igbesẹ 3: Ṣeto aṣa voltage akoko

  1. Baramu voltage akoko lori iwe data ti ilana ti o fẹ. Ilana Aṣa nilo awọn igbewọle 4 lati pari data voltagatunṣe akoko:
    Voltage Timing Definition
    Akoko giga Bit 0 (T0H) Iwọn naatage nilo akoko giga fun koodu 0.
    Akoko giga Bit 1 (T1H) Iwọn naatage nilo akoko giga fun koodu 1.
    Overall Bit Time: Lapapọ voltage time for a single bit.

    Lower limit = T0H+T0L

    Upper limit = T1H+T1L

    Tun Aago Lapapọ voltage kekere akoko ti a beere lati tun awọn gbigbe data laarin kọọkan ipele data.

    ENTTEC-73539-DIN-PIXIE-FIG-9

  2. Datasheet – Data voltage akoko alaye Example
    Lati iwe data WB2818B
    • Locate the ‘Sequence Time’ table in WB2818B’s datasheet for the voltage ìlà ibiti.
    • Kun voltage akoko ibiti o wa ni aaye aṣa ni Awọn Eto Ijade.

      ENTTEC-73539-DIN-PIXIE-FIG-10

PATAKI

  • ENTTEC recommends taking the median value of the range for the start.
  • Olumulo yoo ni lati Fipamọ awọn eto fun iye ti a yipada lati ni ipa.
  • Fine adjustment of value required, followed by actual output test to optimise custom protocol for pixel fixture control.
  • ENTTEC recommends a trial run on the actual setup before finalising the custom protocol setup.
  • Typical issues of incorrect setup include, including and not limited to, failure to light up and output flickering.

IKADI

  • Itọsọna yii ṣe afihan bi o ṣe le ṣeto ilana aṣa fun awọn ẹrọ ENTTEC ti o yẹ ati pese imọ-ẹrọ imọ-ẹrọ lori ijẹrisi iwe data ti awọn imuduro piksẹli ti o fẹ.
  • Nipa titẹle awọn igbesẹ wọnyi, awọn olumulo le ṣẹda Ilana ẹbun aṣa ti a ko rii ninu atokọ-silẹ laisi iduro fun atilẹyin imọ-ẹrọ tabi itusilẹ famuwia tuntun. Ti o ba ni awọn ibeere tabi iṣoro wiwa alaye ti o tọ, de ọdọ ẹgbẹ atilẹyin ọrẹ wa ni awọn ọfiisi agbegbe.

FAQ

How do I access the device settings page on my computer?

You can access the device settings page by connecting your computer to the device's network and entering the IP address in a web kiri ayelujara.

Can I create a custom protocol without the datasheet?

It is recommended to have the datasheet to ensure accurate customization of the protocol based on the pixel fixture's specifications.

Awọn iwe aṣẹ / Awọn orisun

ENTTEC 73539 DIN PIXIE [pdf] Ilana itọnisọna
DIN PIXIE, PIXELATOR MINI, PIXELATOR MINI MK2, OCTO MK2, OCTO MK3, 73539 DIN PIXIE, 73539, DIN PIXIE, PIXIE

Awọn itọkasi

Fi ọrọìwòye

Adirẹsi imeeli rẹ kii yoo ṣe atẹjade. Awọn aaye ti a beere ti wa ni samisi *