FEIG MRM103 Mid Range Reader Module

Awọn awoṣe

AKIYESI
With this edition of the document, all previous editions become void. Indications made in this manual may be changed without previous notice. Copying of this document and giving it to others and the use or communication of the contents thereof are forbidden without express authority. Offenders are liable to the payment of damages. All rights are reserved in the event of the grant of a patent or the registration of a utility model or design. Composition of the information in this document has been done to the best of our knowledge. FEIG ELECTRONIC GmbH does not guarantee the correctness and completeness of the details given in this manual and may not be held liable for damages ensuing from incorrect or incomplete information. Since, despite all our efforts, errors may not be completely avoided, we are always grateful for your useful tips. The instructions given in this manual are based on advantageous boundary conditions. FEIG ELECTRONIC GmbH does not give any guarantee promise for perfect function in cross environments and does not give any guarantee for the functionality of the complete system which incorporates the subject of this document. FEIG ELECTRONIC GmbH calls explicit attention that devices which are subject of this document are not designed with components and testing methods for a level of reliability suitable for use in or in connection with surgical implants or as critical components in any life support systems whose failure to perform can reasonably be expected to cause significant injury to human health. To avoid damage, injury or death the user or application designer must take reasonably prudent steps to protect against system failures. FEIG ELECTRONIC GmbH assumes no responsibility for the use of any information contained in this document and makes no representation that they are free of patent infringement. FEIG ELECTRONIC GmbH does not convey any license under its patent rights nor the rights of others.
Awọn Itọsọna Aabo
- Ẹrọ naa le ṣee lo nikan fun idi ipinnu ti a ṣe nipasẹ olupese.
- Iwe afọwọkọ isẹ yẹ ki o wa ni irọrun wa ni gbogbo igba fun olumulo kọọkan.
- Awọn iyipada laigba aṣẹ ati lilo awọn ẹya ara apoju ati awọn ẹrọ afikun eyiti ko ti ta tabi ṣeduro nipasẹ olupese le fa ina, awọn mọnamọna tabi awọn ipalara. Iru awọn igbese laigba aṣẹ yoo yọkuro eyikeyi layabiliti nipasẹ olupese.
- Awọn iwe ilana layabiliti ti olupese ninu ọran ti o wulo ni akoko rira wulo fun ẹrọ naa. Olupese ko ni ṣe iduro labẹ ofin fun awọn aiṣedeede, awọn aṣiṣe, tabi awọn aṣiṣe ninu iwe afọwọkọ tabi ṣeto awọn aye laifọwọyi fun ẹrọ kan tabi fun ohun elo ti ko tọ ti ẹrọ kan.
- Awọn atunṣe le ṣee ṣe nipasẹ olupese nikan.
- Installation, operation, and maintenance procedures have to be carried out by professional and qualified personnel.
- Lilo ẹrọ ati fifi sori ẹrọ gbọdọ wa ni ibamu pẹlu awọn ibeere ofin orilẹ-ede ati awọn koodu itanna agbegbe.
- Nigbati o ba n ṣiṣẹ lori awọn ẹrọ, awọn ilana aabo to wulo gbọdọ wa ni akiyesi.
- Ṣaaju ki o to fi ọwọ kan ẹrọ naa, ipese agbara gbọdọ wa ni idilọwọ nigbagbogbo. Rii daju wipe ẹrọ ni lai voltage nipa idiwon. Iparẹ ti iṣakoso iṣiṣẹ (LED) kii ṣe itọkasi fun ipese agbara ti o da duro tabi ẹrọ naa ko si ni voltage!
AKIYESI:
- Wearers of pacemakers
- Although this device does not exceed the permissible limits for electromagnetic fields, you should keep a minimum distance of 25 cm between the device and your pacemaker and not stay in the immediate vicinity of the device or the antenna for long periods of time.
History of documentation
| Àtúnyẹwò | Data | Apejuwe |
| 0e | Oṣu Kẹjọ ọdun 2025 | Ẹya akọkọ |
| 1e | Oṣu Kẹwa Ọdun 2025 | Atunṣe kokoro |
Supported documents
| Rara. | Supported documents | Doc.No. |
| [1] | Alaye siwaju sii https://www.feig.de/en/login/ | |
| [2] | Afowoyi | H50420-xe-ID-B |
| [3] | Quick Start PR(M)103-USB | M50630-xde-ID-B |
| [4] | Quick Start MR(M)103-A | M50628-xde-ID-B |
| [5] | Quick Start MR103-E | M50629-xde-ID-B |
| [6] | Quick Start MR(M)103-USBC | M50627-xde-ID-B |
Alaye ti awọn aami
| Aami | Alaye |
| VDC/ |
Volume taaratagaami e |
Ẹya iṣẹ
Ifihan pupopupo
- All reader variants described here have been developed for contactless data exchange with transponders whose operating frequency is 13.56 MHz.
- The ID PR103 has an integrated antenna and works with a transponder-dependent, typical reading range of 20 cm. The reader is equipped with a USB interface for communication with the host.
- The ID MR103 variants are equipped with a connection for an external antenna and work with a transponder-dependent, typical reading range of 40 cm.
- The following interfaces are available for communication with the host: RS232, USB, USBC, Ethernet.
- The “Anticollision” function enables the simultaneous reading of up to 100 x ISO15693 or 20 x I-CODE1 transponders.
- The reader variants are available as a housing version and as a module version.
Reader type code
| Iru oluka | Ẹya | Ni wiwo |
| 79 (Hex.: 0x4F) | A | RS232 |
| USB | USB 2.0 | |
| USBC | USBC | |
| E (Ethernet) | LAN |
Taabu 1: Iru oluka
Pariview

Reader versions
| Onkawe Oriṣi | Firmware | Ẹya | Ni wiwo |
| ID MR103-USB | Standard | Ibugbe | USB |
| ID MRM103-USB | Standard | Modul | USB |
| ID MR103-USBC | Standard | Ibugbe | USBC |
| ID MR103-A | Standard | Ibugbe | RS232 |
| ID MRM103-A | Standard | Modul | RS232 |
| ID MR103-E | Àjọlò | Ibugbe | LAN |
| ID PR103-USB | Standard | Ibugbe | USB |
| ID PRM103-USB | Standard | Modul | USB |
Taabu 2: Reader version
Awọn ipo iṣẹ atilẹyin

Taabu 3: Ipo Iṣiṣẹ
Dopin ti ifijiṣẹ
- 1 x Ẹrọ
- 1 x Quick Start document
Cyber Aabo
Cyber Security (MR103-E)
Ifiranṣẹ ti ẹrọ naa
AKIYESI PATAKI In order to comply with the requirements of the European Radio Equipment Directive (RED) 2014/53/EU article 3 (3), points (d), the following points must be taken into account for the product ID MR103-E:
- When using the network interface (Ethernet), it may be necessary to create at least one user to enable various functions such as changing the configuration. The user and the password MUST be set by the person who puts the device into operation on first use before it is logically connected to a network or by an authorized entity within a network where access is limited to authorized entities.
- When security and/or network assets (keys, certificates, ethernet configuration parameters) are transferred via network interface (Ethernet) TLS encryption must be used to secure the communication.
Cyber Security related Firmware Updates
AKIYESI PATAKI: In order to comply with the requirements of the European Radio Equipment Directive (RED) 2014/53/EU article 3 (3), points (d), you are required to register in the FEIG download area under https://www.feig.de/en/ and subscribe to notifications for cybersecurity-related firmware and software updates for the product ID MR103-E.
Firmware downgrade
AKIYESI PATAKI: A firmware downgrade to older major release versions is not possible in order to prevent old major versions with known cyber security vulnerabilities from being executed on the device.
Fifi sori ẹrọ
Housing version
- The readers are designed for indoor applications.
- Wall and under-counter mounting are possible with the optionally available mounting kit.
Wo 8.1 Wall mounting or under-counter mounting
Awọn iwọn

Modul version
The Module version is intended for installation in customer housings.
Modul dimension [mm]

Ni wiwo Loriview ati Awọn isopọ
Depending on the reader variant, different connections and interfaces are available.

Interface designation
| Asopọmọra | Apejuwe |
| X1 | Power supply 12 – 24V DC/ ± 10% |
| X2 | RS232 & Power supply 12 – 24V DC/ ± 10% |
| X3 | USB / USBC |
| X4 | 10/100Tbase Network interface (RJ45) LAN |
| ANT 1 | Connector ext. antenna (Impedance Ω) |
Taabu 4: Asopọmọra apejuwe
Antenna connection ANT1
There is an SMA socket on the circuit board or on the housing for connecting the external antenna.
AKIYESI:
- The antenna must be adjusted to the value 50 Ω (50 Ω L 15°).
- The optimum operating quality of the antenna should be in the range QB = 10…20. To determine the operating quality, the antenna must be supplied with a 50 Ω source, e.g. a network analyzer or a frequency generator.
- When connecting an antenna, make sure that it does not exceed the permissible limit values of the national regulations regarding radio equipment.
- The maximum tightening torque of the SMA sockets is 0.45 Nm.
DC Voltage on antenna connector ANT1
Iwọn DC kantage can be applied from the reader to the ANT1 antenna connection. This DC voltage can be used to supply an LED, for example.
AKIYESI:
- Iwọn DCtage is only designed for low currents. The DC voltage (6,9 V± 1 V) can be loaded up to a maximum of 5mA.
- Only antennas that are suitable for DC voltage and do not short-circuit the DC voltage may be connected.
- When connecting other devices (e.g. VSWR meters), make sure that they are also suitable for DC voltage.
- Eleyi DC voltage is not suitable for supplying the automatic antenna tuner ID ISC.DAT.
Pariview Ibi ti ina elekitiriki ti nwa
| ID PR(M)103-USB | X3 | 5 VDC / 500 mA (via USB) |
| ID MR(M)103-A | X2 | Pin 1 = GND
Pin 2 = RxD Pin 3 = TxD Pin 4 = GND Pin 5 = 12 bis 24V DC/ |
| ID MR103-E | X1 | External Power Supply Unit (12 bis 24V DC/ |
| ID MR(M)103-USB | X1 | External Power Supply Unit (12 bis 24V DC/ |
| ID MR103-USBC | X3 | 5V DC/ |
Taabu 5: Ibi ti ina elekitiriki ti nwa
X1: External Power Supply*
- The device may only be supplied by a power source in accordance with EN 62368-1 Chapter Q.1 Power sources of limited power or with a power supply unit certified in accordance with NEC Class 2/LPS.
- For more information on available power supply units, see Accessories.
Connector for external Power Supply Unit
X2: RS232 Interface (ID MR103-A)
The transmission parameters can be configured via software protocol.
Connector X2 / Pin Assignment
X3: USB-Interface (ID PR103-USB / ID MR103-USB, USBC)
The USB interface is connected via socket X3 (ID PR103-USB / ID MR103-USB / -USBC). The assignment is standardized. The data rate of the reader is limited to 12 Mbit (USB Full Speed). A standard USBC cable can be used.
AKIYESI: Maximum length of the USB cab e: ≤ 3 m
X4: Ethernet-Interface (ID MR103-E)
- The reader has an integrated 10/100 base-T network interface with standard RJ-45 connection. The connection is made via X4 and has automatic crossover detection in accordance with the 1000BASE-T standard.
- For structured cabling, at least CAT5 category cables should be used. This guarantees problem-free operation at 10 Mbps or 100 Mbps.
- A prerequisite for using the TCP/IP protocol is that each device on the network has its own IP address. All readers have a factory-set IP address.
- The transmission parameters can be configured via software protocol.
| Nẹtiwọọki | Adirẹsi |
| IP-adirẹsi | 192.168.10.10 |
| Subnet-boju | 255.255.255.0 |
| Ibudo | 10001 |
| DHCP | ON |
Taabu 8: Default setting Ethernet Interface
AKIYESI:
- The reader has a DHCP-capable TCP/IP interface.
- A shielded STP (shielded and twisted pair) CAT5 cable must be used.
Ṣiṣẹ ati Awọn eroja Ifihan
Default settings for LED indication

Redio Ifọwọsi
Ikede ibamu (CE)
- CE Ikede ibamu
- Hereby, FEIG ELECTRONIC GmbH declares that the radio equipment type ID PRM103 / ID MRM103 is in compliance with Directive 2014/53/EU.
- Ọrọ kikun ti Ikede Ibamu EU wa ni adirẹsi intanẹẹti atẹle yii: https://www.feig.de/en/service/.
USA (FCC) ati Canada (IC)
AKIYESI: The RFID reader ID PR103 / MR103 contains the RFID module ID PRM103 / MRM103.
| Orukọ ọja: | ID PR103 / MR103 |
| FCC ID: IC: | PJMPRM103 PJMMRM103 6633A-PRM103 6633A-MRM103 |
| Akiyesi fun
USA ati Canada |
Ẹrọ yii ni ibamu pẹlu Apá 15 ti Awọn ofin FCC ati pẹlu RSS-210 ti Ile-iṣẹ Canada.
Isẹ jẹ koko ọrọ si awọn wọnyi meji awọn ipo. (1) ẹrọ yi le ma fa ipalara kikọlu, ati (2) Ẹrọ yii gbọdọ gba kikọlu eyikeyi ti o gba, pẹlu kikọlu ti o le fa iṣẹ ti ko fẹ. Unauthorized modifications may void the authority granted under Federal Communications Commission Rules permitting the operation of this device. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. |
| Ifitonileti ifitonileti igbohunsafẹfẹ redio: | Ohun elo yii ni ibamu pẹlu FCC ati awọn opin ifihan itọka IC ti a ṣeto fun agbegbe ti a ko ṣakoso. Ohun elo yii yẹ ki o fi sori ẹrọ ati ṣiṣẹ pẹlu aaye to kere ju ti 20 cm laarin imooru ati ara rẹ. Atagba yii ko gbọdọ wa ni ipo tabi ṣiṣẹ ni apapo pẹlu eyikeyi eriali miiran tabi atagba. |
AKIYESI: Awọn iyipada tabi iyipada ti a ṣe si ohun elo yii ti ko fọwọsi ni kikun nipasẹ FEIG ELECTRONIC GmbH le sọ aṣẹ FCC di ofo lati ṣiṣẹ ohun elo yii.
Installation with FCC / IC Approval
FCC-/IC-NOTICE: To comply with FCC-Part 15 Rules in the United States / with IC Radio Standards in Canada, the system must be professionally installed to ensure compliance with the Part 15 certification / IC certification. It is the responsibility of the operator and professional installer to ensure that only certified systems are deployed in the United States / Canada.
Aami Alaye
- UThe following information must be placed at the outer side of the housing in which the reader is mounted.
- Contains FCC ID PJMPRM103 Contains FCC ID PJMMRM103
- Contains IC: 6633A-PRM103 Contains IC: 6633A-MRM103
Imọ Data
| Data Mechanical | |
| Housing PR103 / MR103 | Ṣiṣu ABS |
| Iwọn
PR103 MR103 |
150 g
150 g |
| Dimension PR103 / MR103
(wxhxd) |
(145 x 85 x 22) mm |
| Dimension PR103 / MR103 Module
(wxhxd) |
(145 x 77 x 17) mm |
| Weight Modul | 56 g |
| Protection class PR103 / MR103 | IP30 |
| Ibugbe awọ | RAL 9018 (funfun) |
| Itanna Data | |
| Ibi ti ina elekitiriki ti nwa
· ID PR103-USB · ID MR103-A/-USB · ID MRM103-A/-USB · ID MR103-E · ID MR103-USBC |
· 5V DC · 12V DC up to 24V DC · 12V DC up to 24V DC · 12V DC up to 24V DC · Via USB-Type-C (Current at 1.5A) |
| Lilo agbara
ID PR103-USB ID MR103-A, USB, USBC, E |
o pọju. 2.5W ti o pọju. 6W |
| Eriali
PR(M)103-USB |
ese |
| Eriali connector MR(M)103 | 1x SMA-socket (50 W) |
| Ipese voltage on antenna output
MR103 |
6,9V DC ± 1V (5 mA) Antenna output |
| Igbohunsafẹfẹ ṣiṣẹ
PR103-USB ID MR103-A, USB, USBC, E |
13,56 MHz |
| Gbigbe agbara
ID PR103-USB ID MR103-A, USB, USBC, E |
0.6W ± 2dB
1,2W ± 1dB 1,5W ± 1dB |
| Supported transponder | ISO15693, (ISO 18000-3 MODE 1), I-CODE1 |
| Reader modes
ID PR(M)103-USB ID MR(M)103-A, USB, USBC, ID MR(M)103-E |
ISO Host Mode, Scan Mode ISO Host Mode, Scan Mode
ISO Host Mode, Notification Mode |
| 1 * LED | 1 x multicolor LED; (green, blue, red) |
| Awọn atọkun
· ID PR(M)103-USB · ID MR(M)103-A |
· USB
· RS232 |
| · ID MR(M)103-USB
· IS MR(M)103-USBC · ID MR(M)103-E |
· USB
· USB · Ethernet (TCP/IP) |
| Ẹya ara ẹrọ | Short-circuit detection (antenna)
Abojuto iwọn otutu |
| Awọn ipo ayika | |
| Iwọn iwọn otutu | -25°C si +55°C
-40°C si +85°C |
| Ibi ipamọ isẹ | |
| Ojulumo air ọriniinitutu | 5% - 95% (ti kii ṣe itọlẹ) |
| Gbigbọn | EN60068-2-6
10 Hz bis 150 Hz: 0,075 mm / 1 g |
| Iyalẹnu | EN60068-2-27
Isare: 30 g |
| Awọn ifọwọsi | |
| Redio alakosile | · EN 300 330
· FCC 47 CFR-Part 15 · RSS-Gen Issue 1, RSS-210 |
| · Europa / UK
· USA · Canada |
|
| EMV | EN 301 489 |
| Ailewu ati Ilera | EN 62368-1
EN 50364 EN 18031 |
| Vol kekeretage Human Ifihan
Cyber Security (MR103-E) |
|
Awọn ẹya ẹrọ
| Bere fun No. | Iru | Apejuwe | |
| 1688.002.00 | ID NET.12V-B-EU Power Supply Unit 12V | Supply unit 100 – 240V AC, (Angled plug, EU),
Output: 12V DC/ ; 50Hz / 60Hz, 700mA |
|
| 3886.000.00 | ID NET.12V-B-GB Power Supply Unit 12V | Supply unit 100 – 240V AC, (Angled plug, GB) | |
| 3887.000.00 | ID NET.12V-B-US Power Supply Unit 12V | Supply unit 100 – 240V AC, (Angled plug, US) | |
| 7224.000.00 | ID MS.MR103/PR103-A | Wall mounting or under-counter mounting | |
| 7102.000.00 | ID CAB.RS-T | Cable for RS232 and Power Supply (ID MR103-A) | |
| 7103.000.00 | ID CAB.USB-AC | USB Interface cable, USB-A auf USBC | |
| 7104.000.00 | ID CAB.USB-CC | USB Interface cable, USBC auf USBC | |
| Eriali ti ita | |||
| 1663.000.00 | ID ISC.ANT340/240-A | Dim.: Protection.: | 340mm x 240mm x 9mm IP20 |
| 2396.000.00 | ID ISC.ANT340/240-B | Ita eriali lai ile | |
| 3249.000.00 | ID ISC.ANT310/310-A | Dim.: Protection.: | 318mm x 338mm x 30mm IP65 |
| 3512.000.00 | ID ISC.ANTS370/270 | Dim.: Protection.: | 370mm x 270mm x 27mm IP20 |
| 6612.000.00 | ID ANT240/180-A | Dim.: Protection: | 40mm x 180mm x 13mm IP30 |
| 6616.000.00 | ID ANTS240/180-A | Dim.: Protection: | 240mm x 180mm x 15mm IP30 |
| 1968.000.00 | ID ISC.ANT100/100-A | External antenna without housing Dim.: 40mm x 30mm x 6mm | |
| 1967.000.00 | ID ISC.ANT40/30-A | Ita eriali lai ile
Dim.: 100mm x 100mm x 6mm |
|
Taabu 10: Awọn ẹya ẹrọ
Wall mounting or under counter mounting
- Remove the screws on the back of the reader.
- The mounting brackets are fastened with the previously removed screws.
- They can also be mounted rotated by 90° as an option.

Akiyesi: The mounting kit “ID MS.MR103/PR103-A” includes the four mounting brackets (See Accessories).
Serial Data Cable ID CAB.RS-T
| PIN | Ifihan agbara | Farbe / Color | X2 |
| 1 | GND | Yellow | ![]() |
| 2 | RxD | ọsan | |
| 3 | TXD | Brown | |
| 4 | GND | Dudu | |
| 5 | 12 bis 24V DC/ |
Pupa |

- Iwe aṣẹ: Fifi sori ẹrọ
- Id-Nr. Document Version: M50720-0e-ID-B
- Ọjọ: 30.10.25
IBI IWIFUNNI
- © Aṣẹ-lori-ara
- All brand names, product names or trademarks mentioned are the property of their respective owners.
- FEIG itanna GmbH
- Industriestraße 1a
- 35781 Weilburg, Jẹmánì
- Tẹli.: + 49 6471 3109-0
- Oju ewe: https://www.feig.de/en/
- Imeeli: idamo-support@feig.de.
FAQs
- Ṣe MO le ṣe awọn iyipada si ẹrọ naa?
- No, unauthorized changes and the use of spare parts and additional devices which have not been sold or recommended by the manufacturer may cause fire, electric shocks or injuries. Such unauthorized measures shall exclude any liability by the manufacturer.
- Who can perform repairs on the device?
- Awọn atunṣe le ṣee ṣe nipasẹ olupese nikan.
- What should I do before handling the device?
- Ṣaaju ki o to fi ọwọ kan ẹrọ naa, ipese agbara gbọdọ wa ni idilọwọ nigbagbogbo. Rii daju wipe ẹrọ ni lai voltage by measuring. The fading of an operation control (LED) is no indicator for an
- interrupted power supply or the device being out of voltage!
- Nibo ni MO ti le rii ẹya tuntun ti itọnisọna naa?
- With this edition of the document, all previous editions become void. Indications made in this manual may be changed without previous notice. For the most current information, it is recommended to contact FEIG ELECTRONIC GmbH.
Awọn iwe aṣẹ / Awọn orisun
![]() | MRM103 Mid Range Reader Module |
Awọn itọkasi
- CAB.RScab.rs
- Doc.Nodoc.no
- mailto:Identification-support@feig.defeig.de
- nord.denord.de
- feig.de/en/www.feig.de
- feig.de/en/login/www.feig.de
- feig.de/en/service/www.feig.de
- Itọsọna olumulomanual.tools