WEINTEK KEYENCE KV-8000-KV-X Symbolic Ethernet Programmable Logic Controller

WEINTEK-KEYENCE-KV-8000-KV-X-Symbolic-Ethernet-Programmable-Logic-Controller-product

Awọn pato

Ilana fifi sori ẹrọ

Eto HMI: 

Awọn paramita Ti ṣe iṣeduro Awọn aṣayan Awọn akọsilẹ
PLC iru KEYENCE KV-8000/KV-X (Symbolic) (Ethernet)
PLC I/F Àjọlò
Port No. 8500
Iru ẹrọ KV8000 KV8000 / KVX
Simulator ori ayelujara Bẹẹni Multi-HMI so Bẹẹni

Si ilẹ okeere Tags:

Software KV STUDIO creates tag:

  1. Variable -> Cerected tag on Global or Local table.WEINTEK-KEYENCE-KV-8000-KV-X-Symbolic-Ethernet-Programmable-Logic-Controller-fig1
  2. Support Sturcutre address. WEINTEK-KEYENCE-KV-8000-KV-X-Symbolic-Ethernet-Programmable-Logic-Controller-fig2
  3. Si ilẹ okeere tag: File -> Output CSV/TXT file -> Variable information WEINTEK-KEYENCE-KV-8000-KV-X-Symbolic-Ethernet-Programmable-Logic-Controller-fig3

gbe wọle Tags:

  1. In EasyBuilder Pro -> System Parameter Settings -> New Driver (KV-8000) -> Import Tags. WEINTEK-KEYENCE-KV-8000-KV-X-Symbolic-Ethernet-Programmable-Logic-Controller-fig4
  2. Select the .txt file lati gbe wọle. WEINTEK-KEYENCE-KV-8000-KV-X-Symbolic-Ethernet-Programmable-Logic-Controller-fig5
  3. Import some or all of the tags WEINTEK-KEYENCE-KV-8000-KV-X-Symbolic-Ethernet-Programmable-Logic-Controller-fig6
  4. Yan awọn tag you want to import in Tag Manager, press OK. WEINTEK-KEYENCE-KV-8000-KV-X-Symbolic-Ethernet-Programmable-Logic-Controller-fig7
  5. Akowọle tag alaye ni ifijišẹ. WEINTEK-KEYENCE-KV-8000-KV-X-Symbolic-Ethernet-Programmable-Logic-Controller-fig8

Support Device Iru

Iru data EasyBuilder data kika Akọsilẹ
BOOL die-die
INT 16-bit BCD, hex, alakomeji, wole 16-bit
UNINT 16-bit BCD, Hex, Alakomeji, Unsigned 16-bit
DINT 32-bit BCD, hex, alakomeji, wole 32-bit
UDINT 32-bit BCD, Hex, Alakomeji, Unsigned 32-bit
ODODO 32-bit leefofo 32-bit
LÒÓTỌ́ 64-bit leefofo 64-bit * Akọsilẹ1
OKUN Eto ọrọ fun titẹ sii ASCII ati ifihan * Akọsilẹ2
 

Akopọ

BOOL, INT, UINT, DINT,UDINT, REAL,

LREAL, Structure

* Akọsilẹ3

 

Ilana

BOOL, INT, UINT, DINT,UDINT, REAL, LREAL, STRING

Akopọ

  • Akiyesi1: EBPro V6.03.02 tabi nigbamii ṣe atilẹyin iru data 64 bits (cMT Series nikan), ṣugbọn jọwọ ṣe akiyesi pe opin opin adirẹsi jẹ 48 die-die ni o pọju.
  • Akiyesi 2: String In EasyBuilder Pro, only even addresses can be selected, and support string length up to 2000.WEINTEK-KEYENCE-KV-8000-KV-X-Symbolic-Ethernet-Programmable-Logic-Controller-fig9
  • Akiyesi 3: Support 1~3D array, 4D arrays and above cannot be imported.

Aworan onirin

okun àjọlò:

WEINTEK-KEYENCE-KV-8000-KV-X-Symbolic-Ethernet-Programmable-Logic-Controller-fig10

FAQs

How do I connect multiple HMIs?

You can connect multiple HMIs using the on-line simulator option in the HMI settings.

What is the maximum string length supported for STRING data type?

In EasyBuilder Pro, only even addresses can be selected, and it supports string length up to 2000.

Awọn iwe aṣẹ / Awọn orisun

WEINTEK KEYENCE KV-8000-KV-X Symbolic Ethernet Programmable Logic Controller [pdf] Itọsọna olumulo
KEYENCE KV-8000-KV-X, KEYENCE KV-8000-KV-X Symbolic Ethernet Programmable Logic Controller, Symbolic Ethernet Programmable Logic Controller, Ethernet Programmable Logic Controller, Programmable Logic Controller, Logic Controller